4.2.3.3 Error Code Description
To manage camera reliability, not-acknowledge error codes are defined as follows:
x00 – No error
x01 – Invalid command. An invalid command (not 52 or 57) has been sent to the
camera.
x02 – Time-out.
x03 – Checksum error
x04 – Value less then minimum
x05 – Value higher than maximum
x06 – AGC error
x07 – Supervisor mode error
x08 – Mode not supported error