Table 2.4b – BOBCAT Output Mapping
2.11.2 Electrical Connectivity
A.
Inputs IN1 and IN2
The external inputs in BOBCAT (GigE or CL models) are directly connected to the
camera hardware – Figure 2.26. The input signals “Signal” and “Return” are used to
connect to an external Input to the outside source. The signal level (voltage
difference between the inputs “Signal” and “Return”)
MUST
be LVTTL (3.3 volts)
or TTL (5.0 volts). The total maximum input current
MUST NOT
exceed 2.0 mA.
There are no restrictions for the minimum or maximum duration.
TO I/O CONTROL
2 mA MAX
R4
300
Input
BNC
1
2
Return
Signal
1
2
D1
6.2V
Figure 2.26 – IN1, IN2 electrical connection.
B.
Outputs OUT1 and OUT2
The external outputs in BOBCAT (GigE or CL models) are directly connected to the
camera hardware, and are TTL (5.0 Volts) compatible signals. The maximum output
current
MUST NOT
exceed 8 mA. Figure 2.27 shows the output external electrical
connection.
8 mA MAX
R5
100
Output
BNC
1
2
Signal
Return
3
4
FROM I/O CONTROL
Figure 2.27 – OUT1, OUT2 electrical connection.
CAUTION NOTE