4.3.2.7
Save to User #2
The
‘Save To User #2’
command instructs the camera to save its workspace to the
user #2 space. All current workspace settings will be saved to the user #2 space. This
is a command, not a register. The act of writing to this location initiates the save to
user #2 space.
Address
:
0x6078
4.3.2.8
SW_Reset
The
‘SW_Reset’
command instructs the camera to initiate software reset, which resets
the camera and loads its workspace from one of the configuration spaces as
determined by the ‘Boot From’ data.
Although, this is a command, the user MUST
write a specific data 0xDEADBEEF in order to initiate the reset sequence.
Address
:
0x601C
Data
:
0xDEADBEEF
4.3.2.9
BAUD Rate Selector
This register sets the communication baud rate between the camera and computer.
Address
:
0x0604
Data (2:0)
:
000 – 9600
001 – 19200
010 – 38400
011 – 57600
100 – 115200 (default)
Data (31:3)
:
N/A