CAMERAS FRAME GRABBERS IMAGING SOLUTIONS
BOBCAT Hardware User’s Manual
IMPERX
Rev. 2.0.9
6421 Congress Ave.
4/8/2014
Boca Raton, FL 33487
www.imperx.com
+1 (561) 989-0006
185 of 329
For all Bobcat cameras with Camera link output - all inputs and outputs
ARE NOT
optically isolated for a HW revision “RA04”
or later.
C.
Lens Control Output for Iris, Focus, and Zoom
The external Lens Control outputs for CLB, and GEV cameras are directly
connected to the camera hardware, and operate in either 6 or 12 volts. The maximum
average output current
MUST NOT
exceed 400 mA with all three motors operating
at the same time. Figure 2.13 shows the output external electrical connection.
Figure 2.28 – Lens Control output electrical connection.
Note: ICL and IGV cameras do not support Lens Control. Only CLB, CLM, and
GEV cameras support Lens Control.
D.
Custom GPIO (IN/OUT)
BOBCAT (GigE or CL models) has a provision for a high-speed custom general
purpose I/O – LVTTL (3.3 Volts) compatible. The maximum output current
MUST
NOT
exceed 8 mA, and the maximum input current
MUST NOT
exceed 2.0 mA.
This GPIO is not currently enabled. If your application requires such configuration
please contact IMPERX for more information.
E.
Custom SPI Interface
BOBCAT (CL models ONLY) has a provision for a high-speed custom SPI interface
– LVTTL (3.3 Volts) compatible. The interface can be available via the mini USB
connector on the back of the camera. This SPI interface is not currently enabled. If
your application requires such interface please contact IMPERX for more
information.