![Imperx BOBCAT B0610C Скачать руководство пользователя страница 269](http://html1.mh-extra.com/html/imperx/bobcat-b0610c/bobcat-b0610c_user-manual_2048991269.webp)
CAMERAS FRAME GRABBERS IMAGING SOLUTIONS
BOBCAT Hardware User’s Manual
IMPERX
Rev. 2.0.7
6421 Congress Ave.
4/8/2014
Boca Raton, FL 33487
www.imperx.com
+1 (561) 989-0006
269 of 329
Granularity:
Sets the granularity for the internal counters. Granularity can be set to 1x,
10x, 100x or 1000x.
Period
:
Sets the pulse period in microseconds.
Width
:
Sets the pulse width in microseconds.
# of Pulses
:
Sets the number of pulses generated. Two modes are available:
1.
Continuous – provides a continuous operation. To stop the process you
have to press the “Stop” button.
2.
Fixed # of pulses
– the user can set only a discrete number of pulses
ranging (1 to 65500) to be generated. To stop the process you have to
press the “Stop” button. Otherwise, the process stops automatically after
the last pulse is sent.
Process
:
Start
– starts and stops the process of Internal Pulse Generator. When the
process is in progress, the ‘Start” button becomes a ‘Stop” button.
Status
– provides the status of the process:
Red – the process is on hold,
Green – the process is working.
5.7.5 Exposure
This window controls the camera exposure, line and frame time, AEC, AGC and AIC
modes of operation – Figure 5.14.