258 of 329
Save To:
Saves the camera
registers to File, User Space #1 or User Space #2. Factory
Space is disabled for regular users and it is available only for manufacturing
technicians.
1.
File
– saves the current camera settings to a configuration file
2.
Factory Space
– saves the current camera settings to the camera Factory
space. This is restricted command and is disabled for regular users.
3.
User Space #1
– saves the current camera settings to the camera User
space 1.
4.
User Space #2
– saves the current camera settings to the camera User
space 2.
Boot:
This menu selects the ‘Boot From’ source. Upon power up, the camera will
load its registers from the selected ‘Boot From’ source: Factory, User #1 or
User #2. Bobcat camera will be release with ‘Factory” Setting and user can
save and boot camera with their own configurable features.
DPM:
Defect Pixel Map – When selected, the DPM window will show defected
pixels location. The defective pixel map is stored in the camera’s non-
volatile memory and read out when running bad pixel correction – Figure
5.4. Defected pixels are categorized as:
Figure 5.4 – Defective pixel map
1.
Dead Pixels
– pixels with sensitivity that deviates more than 15% due to
fluctuations in the CCD manufacturing process.