The DPV1 command channel
DPV1 command 0dec (00hex): no execution of a command
11-4
11.3
DPV1 command 0
dec
(00
hex
): no execution of a command
Request of DPV1 master
Bit
Word
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1
user ID
command request = 65
hex
2
0
command number = 00
hex
= 0
dec
3…19
ignored ignored
Legend
→
page
Example:
Word no.
Value [hex]
Description
1 0365
03 = user ID changes e.g. to 3
65 = command request
2
0000
00 = command number 0
3…18 0000
not
used
Response from controllere (DPV1 slave)
Bit
Word
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1
reflected user ID
command status = 6F
hex
2
reserved
reflected command number = 00
hex
3…19
ignored ignored
Example:
Word no.
Value [hex]
Description
1 036F
03 = reflected user ID changes e.g. to 3
6F = command status is "ready" (no fault)
2
0000
00 = reflected command number 0
3…18 0000
not
changed
Содержание Ecomat 300 AC1355
Страница 8: ...8 15 Terms abbreviations 15 1 16 Index 16 1 ...
Страница 12: ...On this manual Overview where is what 1 4 ...
Страница 14: ...Safety instructions Functions and features 2 2 ...
Страница 16: ...System requirements Required accessories 3 2 ...
Страница 18: ...Getting started Set up Profibus DPV1 4 2 ...
Страница 24: ...Menu Main menu Fieldbus Setup 6 4 ...
Страница 52: ...Set up Finish set up 7 28 ...
Страница 76: ...DP module 7 Command channel Module 7 command 63dec 3Fhex no operation command without function 8 24 ...
Страница 226: ...The DPV1 command channel DPV1 command 105dec 69hex read the device properties of the controllere 11 72 ...
Страница 238: ...Technical data Profibus DP interface 13 2 ...
Страница 246: ...Terms abbreviations 15 6 ...
Страница 248: ...Index 16 2 System Save parameters 12 10 Target 15 5 TFR Register 14 2 Troubleshooting 14 1 Watchdog 15 5 ...