IDT SMBus Interfaces
PES16NT2 User Manual
6 - 13
April 15, 2008
Notes
Sample Slave SMBus Operation
This section illustrates sample Slave SMBus operations. Shaded items are driven by the PES16NT2’s
slave SMBus interface and non-shaded items are driven by an SMBus host.
Figure 6.8 CSR Register Read Using SMBus Block Write/Read Transactions with PEC Disabled
Bit
Field
Name
Type
1
1.
See Table 2 in the About section for a definition of these abbreviations.
Description
0
OP
RW
Serial EEPROM Operation. This field encodes the serial EEPROM
operation to be performed.
0 - Serial EEPROM write
1 - Serial EEPROM read
1
USA
RW
Use Specified Address
. When this bit is set the serial EEPROM
SMBus address specified in the EEADDR is used instead of that
specified in the MSMBADDR field in the SMBUSSTS register.
2
Reserved
Reserved field.
3
NAERR
RC
No Acknowledge Error. This bit is set if an unexpected NACK is
observed during a master SMBus transaction when accessing the
serial EEPROM. This bit has the same function as the NAERR bit in
the PA_SMBUSSTS register.
The setting of this bit may indicate the following: that the addressed
device does not exist on the SMBus (i.e., addressing error), data is
unavailable or the device is busy, an invalid command was detected
by the slave, invalid data was detected by the slave.
4
LAERR
RC
Lost Arbitration Error. This bit is set if the master SMBus interface
loses 16 consecutive arbitration attempts when accessing the serial
EEPROM. This bit has the same function as the LAERR bit in the
PA_SMBUSSTS register.
5
OTHERERR
RC
Other Error. This bit is set if a misplaced START or STOP condition is
detected by the master SMBus interface when accessing the serial
EEPROM. This bit has the same function as the OTHERERR bit in
the PA_SMBUSSTS register.
7:6
Reserved
0
Reserved. Must be zero
Table 6.12 Serial EEPROM Read or Write CMD Field Description
DATAUU
N
DATAUM
A
BYTCNT=7
A
ADDRL
CMD (status)
S
PES16NT2 Slave
SMBus Address
Wr
A
A
BYTCNT=3
A
CMD=read
A
ADDRL
A
ADDRU
A
P
CCODE
START,END
S
PES16NT2 Slave
SMBus Address
Wr
A
A
CCODE
START,END
S
PES16NT2 Slave
SMBus Address
Rd
DATALM
DATALL
A
A
A
A
A
P
ADDRU
A
S
PES16NT2 Slave
SMBus Address
Wr
A
N
CCODE
START,END
P
(PES16NT2 not ready with data)
Содержание 89HPES16NT2
Страница 14: ...DT List of Figures PES16NT2 User Manual viii April 15 2008 Notes...
Страница 20: ...IDT Register List PES16NT2 User Manual xiv April 15 2008 Notes...
Страница 32: ...IDT PES16NT2 Device Overview PES16NT2 User Manual 1 12 April 15 2008 Notes...
Страница 44: ...IDT Clocking Reset and Initialization Clock Operation PES16NT2 User Manual 2 12 April 15 2008 Notes...
Страница 50: ...IDT Link Operation PES16NT2 User Manual 3 6 April 15 2008 Notes...
Страница 62: ...IDT Power Management PES16NT2 User Manual 5 4 April 15 2008 Notes...
Страница 78: ...IDT SMBus Interfaces PES16NT2 User Manual 6 16 April 15 2008 Notes...
Страница 83: ...IDT NTB Upstream Port Failover PES16NT2 User Manual 7 5 April 15 2008 Notes...
Страница 84: ...IDT NTB Upstream Port Failover PES16NT2 User Manual 7 6 April 15 2008 Notes...
Страница 130: ...IDT Transparent Mode Operation PES16NT2 User Manual 9 44 April 15 2008 Notes...
Страница 284: ...IDT Non Transparent Mode Operation PES16NT2 User Manual 10 154 April 15 2008 Notes...