IDT Transparent Mode Operation
PES16NT2 User Manual
9 - 24
April 15, 2008
Notes
PA_PCIESCAP - PCI Express Slot Capabilities (0x054)
12
SCLK
RWL
HWINIT
Slot Clock Configuration
. When set, this bit indicates that
the component uses the same physical reference clock
that the platform provides. The initial value of this field is
the state of the CCLKUS signal for port A and the CCLKDS
signal for downstream port C. The value contained in Serial
EEPROM may override these default values.
15:13
Reserved
RO
0x0
Reserved field.
Bit
Field
Field
Name
Type
Default
Value
Description
0
ABP
RO
0x0
Attention Button Present
. Hot-plug is not supported.
1
PCP
RO
0x0
Power Control Present
. Hot-plug is not supported.
2
MRLP
RO
0x0
MRL Sensor Present
. Hot-plug is not supported.
3
ATTIP
RO
0x0
Attention Indicator Present
. Hot-plug is not supported.
4
PWRIP
RO
0x0
Power Indicator Present
. Hot-plug is not supported.
5
HPS
RO
0x0
Hot Plug Surprise
. Hot-plug is not supported.
6
HPC
RO
0x0
Hot Plug Capable
. Hot-plug is not supported.
14:7
SPLV
RWL
0x0
Slot Power Limit Value
. In combination with the Slot
Power Limit Scale, this field specifies the upper limit on
power supplied by the slot.
A Set_Slot_Power_Limit message is generated using this
field whenever this register is written or when the link tran-
sitions from a non DL_Up status to a DL_Up status.
This bit is read-only and has a value of zero when the
SLOT bit in the PCIECAP register is cleared.
16:15
SPLS
RWL
0x0
Slot Power Limit Scale
. This field specifies the scale used
for the Slot Power Limit Value (SPLV).
0x0 - (x1) 1.0x
0x1 - (xp1) 0.1x
0x2 - (xp01) 0.01x
0x3 - (xp001) 0.001x
A Set_Slot_Power_Limit message is generated using this
field whenever this register is written or when the link tran-
sitions from a non DL_Up status to a DL_Up status.
This bit is read-only and has a value of zero when the
SLOT bit in the PCIECAP register is cleared.
17
EIP
RWL
0x0
Electromechanical Interlock Present
. Hot-plug is not
supported.
18
NCCS
RO
0x0
No Command Completed Support
. Hot-plug is not sup-
ported.
Bit
Field
Field
Name
Type
Default
Value
Description
Содержание 89HPES16NT2
Страница 14: ...DT List of Figures PES16NT2 User Manual viii April 15 2008 Notes...
Страница 20: ...IDT Register List PES16NT2 User Manual xiv April 15 2008 Notes...
Страница 32: ...IDT PES16NT2 Device Overview PES16NT2 User Manual 1 12 April 15 2008 Notes...
Страница 44: ...IDT Clocking Reset and Initialization Clock Operation PES16NT2 User Manual 2 12 April 15 2008 Notes...
Страница 50: ...IDT Link Operation PES16NT2 User Manual 3 6 April 15 2008 Notes...
Страница 62: ...IDT Power Management PES16NT2 User Manual 5 4 April 15 2008 Notes...
Страница 78: ...IDT SMBus Interfaces PES16NT2 User Manual 6 16 April 15 2008 Notes...
Страница 83: ...IDT NTB Upstream Port Failover PES16NT2 User Manual 7 5 April 15 2008 Notes...
Страница 84: ...IDT NTB Upstream Port Failover PES16NT2 User Manual 7 6 April 15 2008 Notes...
Страница 130: ...IDT Transparent Mode Operation PES16NT2 User Manual 9 44 April 15 2008 Notes...
Страница 284: ...IDT Non Transparent Mode Operation PES16NT2 User Manual 10 154 April 15 2008 Notes...