2
WHEN CONNECTING TO THE NETWORK THROUGH A PC
21
■
Radio’s presetting
The RS-BA1 remotely controls Icom radios using CI-V (Icom Communication Interface) commands. See the CI-V
command table in the radio’s instruction manual for details of the functions that can be controlled.
D
The following manual settings are required when operating the RS-BA1
Properly preset the items in below table for functions that cannot be controlled by CI-V commands or the item may
cause unwanted actions. See the radio’s instruction manual for details of the settings or operation.
NOTE:
• Remove the transverter from the radio, if it is connected.
• To prevent an accidental transmission, we recommend you remove any keyer, keypad or other external equipment
connected to the radio.
• Set the radio to a normal operating mode. The radio cannot receive CI-V commands while in special modes, such
as the firmware update mode or cloning mode.
• If the radio has a Time-Out Timer function, we recommend you enable it to prevent the radio from continuously
transmitting.
If you are using the IC-PW1 with the transceiver, be sure to set the CI-V baud rate to 19200 bps. After changing
the transceiver’s CI-V settings, be sure to reset the CPU of the IC-PW1 and set the transceiver’s CI-V settings on
the IC-PW1. See the IC-PW1 instruction manual for details.
Genre
Item
Model
Setting
Function
RIT function
All
Set to OFF.
∂
TX function
All
Set to OFF.
Simple band scope
IC-746PRO*/IC-7000*/IC-7100/
IC-7400*/IC-9100
Set to OFF.
SWR Measurement func-
tion
IC-746PRO*/IC-7000*/IC-7100/
IC-7400*/IC-9100
Set to OFF.
Timer/Sleep Timer func-
tion
Radios with the timer function
Set the timer to OFF or to your
schedule.
Weather Alert function
IC-7100
Set to OFF.
Display
RTTY decode screen
IC-746PRO*/IC-756PROIII*/IC-7400*
Exit the screen.
Volume
Volume for the RX audio All
Set the volume to a suitable level.
CI-V
CI-V address
All
Set an appropriate CI-V address.
CI-V baud rate
All
Set to 19200 bps (or Auto).
CI-V USB Port
IC-7300/
IC-7850 (Firmware version 1.10 or later)/
IC-7851 (Firmware version 1.10 or later)
To use the Scope function when
connecting to the USB port, set
to Unlink from [REMOTE].
CI-V USB Baud Rate
IC-7300/
IC-7850 (Firmware version 1.10 or later)/
IC-7851 (Firmware version 1.10 or later)
To use the Scope function when
connecting to the USB port, set
to 115200 (or Auto).
Set mode
USB Serial Function
Radios with a USB (B type) port
Set to “CI-V” for the selected
connection type.
RS-232C Function
Radios with an RS-232C port
Set to “CI-V” for the selected
connection type.
* Operation on models without a USB connection cannot be guaranteed.