Table 26. Error event IDs and error codes (continued)
Event
ID
Notification
type
Condition
Error
code
009173
W
The FlashCopy feature has exceeded the amount that is
licensed.
3032
009174
W
The Metro Mirror or Global Mirror feature has exceeded
the amount that is licensed.
3032
009175
W
The usage for the thin-provisioned volume is not
licensed.
3033
009176
W
The value set for the virtualization feature capacity is not
valid.
3029
009177
E
A physical disk FlashCopy feature license is required.
3035
009178
E
A physical disk Metro Mirror and Global Mirror feature
license is required.
3036
009179
E
A virtualization feature license is required.
3025
009180
E
Automatic recovery of offline node failed.
1194
009181
W
Unable to send email to any of the configured email
servers.
3081
009182
W
The external virtualization feature license limit was
exceeded.
3032
009183
W
Unable to connect to LDAP server.
2251
009184
W
The LDAP configuration is not valid.
2250
010002
E
The node ran out of base event sources. As a result, the
node has stopped and exited the system.
2030
010003
W
The number of device logins has reduced.
1630
010006
E
A software error has occurred.
2030
010008
E
The block size is invalid, the capacity or LUN identity
has changed during the managed disk initialization.
1660
010010
E
The managed disk is excluded because of excessive
errors.
1310
010011
E
The remote port is excluded for a managed disk and
node.
1220
010012
E
The local port is excluded.
1210
010013
E
The login is excluded.
1230
010014
E
The local port is excluded.
1211
010017
E
A timeout has occurred as a result of excessive
processing time.
1340
010018
E
An error recovery procedure has occurred.
1370
010019
E
A managed disk I/O error has occurred.
1310
010020
E
The managed disk error count threshold has exceeded.
1310
010021
W
There are too many devices presented to the cluster
(system).
1200
010022
W
There are too many managed disks presented to the
cluster (system).
1200
010023
W
There are too many LUNs presented to a node.
1200
010024
W
There are too many drives presented to a cluster
(system).
1200
Chapter 9. Event reporting
121
||||
||||
Содержание Storwize V7000
Страница 1: ...IBM Storwize V7000 Version 6 3 0 Troubleshooting Recovery and Maintenance Guide GC27 2291 02...
Страница 6: ...vi Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 8: ...viii Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 10: ...x Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 34: ...18 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 42: ...26 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 80: ...64 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 128: ...112 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 156: ...140 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 166: ...150 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 171: ......
Страница 172: ...Printed in USA GC27 2291 02...