Table 25. Informational events (continued)
Event ID
Notification
type
Description
981101
I
SAS discovery occurred; no configuration changes
were detected.
981102
I
SAS discovery occurred; configuration changes are
pending.
981103
I
SAS discovery occurred; configuration changes are
complete.
981104
W
The LUN capacity equals or exceeds the maximum
capacity. Only the first 1 PB of disk will be accessed.
981105
I
The drive format has started.
981106
I
The drive recovery was started.
982003
W
Insufficient virtual extents.
982004
W
The migration suspended because of insufficient
virtual extents or too many media errors on the
source managed disk.
982007
W
Migration has stopped.
982009
I
Migration is complete.
982010
W
Copied disk I/O medium error.
983001
I
The FlashCopy operation is prepared.
983002
I
The FlashCopy operation is complete.
983003
W
The FlashCopy operation has stopped.
984001
W
First customer data being pinned in a virtual disk
working set.
984002
I
All customer data in a virtual disk working set is
now unpinned.
984003
W
The volume working set cache mode is in the process
of changing to synchronous destage because the
volume working set has too much pinned data.
984004
I
Volume working set cache mode updated to allow
asynchronous destage because enough customer data
has been unpinned for the volume working set.
984501
I
The firmware level of an enclosure component is
being updated.
984502
I
The firmware level updated has completed.
984503
I
The battery conditioning completed.
984504
I
The battery conditioning started.
984505
I
The statesave information for the enclosure was
collected.
984506
I
The debug from an IERR was extracted to disk.
984507
I
An attempt was made to power on the slots.
984508
I
All the expanders on the strand were reset.
984509
I
The component firmware update paused to allow the
battery charging to finish.
984511
I
The update for the component firmware paused
because the system was put into maintenance mode.
118
Storwize V7000: Troubleshooting, Recovery, and Maintenance Guide
Содержание Storwize V7000
Страница 1: ...IBM Storwize V7000 Version 6 3 0 Troubleshooting Recovery and Maintenance Guide GC27 2291 02...
Страница 6: ...vi Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 8: ...viii Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 10: ...x Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 34: ...18 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 42: ...26 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 80: ...64 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 128: ...112 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 156: ...140 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 166: ...150 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 171: ......
Страница 172: ...Printed in USA GC27 2291 02...