Table 26. Error event IDs and error codes (continued)
Event
ID
Notification
type
Condition
Error
code
045058
E
An enclosure battery is at end of life.
1113
045062
W
An enclosure battery conditioning is required but not
possible.
1131
045063
E
There was an enclosure battery communications error.
1116
045064
W
A SAS port is active, but no enclosures can be detected.
1005
045065
E
There is a connectivity problem between a canister and
an enclosure.
1036
045066
E
The FRU identity of the enclosure is not valid.
1008
045067
W
A new enclosure FRU was detected and needs to be
configured.
1041
045068
E
The internal device on a node canister was excluded
because of too many change events.
1034
045069
E
The internal connector on the node canister was
excluded as the cause of single ported drives.
1034
045070
W
The canister temperature sensor cannot be read.
1034
045071
W
The enclosure contains both a node canister and an
expansion canister.
1037
045072
E
The discovery failed to complete.
1048
045073
E
The VPD for the enclosure cannot be read.
1048
045080
E
There are too many self-initiated resets on the enclosure.
1048
045082
E
The slots are powered off.
1048
050001
W
The relationship is stopped because of a clustered system
or complete I/O group failure, and the current state of
the mapping could not be recovered.
1700
050002
W
A Metro Mirror or Global Mirror relationship or
consistency group exists within a clustered system, but
its partnership has been deleted.
3080
050010
W
A Global Mirror relationship has stopped because of a
persistent I/O error.
1920
050011
W
A remote copy has stopped because of a persistent I/O
error.
1915
050020
W
A Metro Mirror or Global Mirror relationship has
stopped because of an error that is not a persistent I/O
error.
1720
050030
W
There are too many cluster (system) partnerships. The
number of partnerships has been reduced.
1710
050031
W
There are too many cluster (system) partnerships. The
system has been excluded.
1710
060001
W
The thin-provisioned volume copy is offline because
there is insufficient space.
1865
060002
W
The thin-provisioned volume copy is offline because the
metadata is corrupt.
1862
060003
W
The thin-provisioned volume copy is offline because the
repair has failed.
1860
126
Storwize V7000: Troubleshooting, Recovery, and Maintenance Guide
|||
|
|
|||
|
|
Содержание Storwize V7000
Страница 1: ...IBM Storwize V7000 Version 6 3 0 Troubleshooting Recovery and Maintenance Guide GC27 2291 02...
Страница 6: ...vi Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 8: ...viii Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 10: ...x Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 34: ...18 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 42: ...26 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 80: ...64 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 128: ...112 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 156: ...140 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 166: ...150 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 171: ......
Страница 172: ...Printed in USA GC27 2291 02...