Table 26. Error event IDs and error codes (continued)
Event
ID
Notification
type
Condition
Error
code
010025
W
A disk I/O medium error has occurred.
1320
010026
W
A suitable MDisk or drive for use as a quorum disk was
not found.
1330
010027
W
The quorum disk is not available.
1335
010028
W
A controller configuration is not supported.
1625
010029
E
A login transport fault has occurred.
1360
010030
E
A managed disk error recovery procedure (ERP) has
occurred. The node or controller reported the following:
v
Sense
v
Key
v
Code
v
Qualifier
1370
010031
E
One or more MDisks on a controller are degraded.
1623
010032
W
The controller configuration limits failover.
1625
010033
E
The controller configuration uses the RDAC mode; this is
not supported.
1624
010034
E
Persistent unsupported controller configuration.
1695
010040
E
The controller system device is only connected to the
node through a single initiator port.
1627
010041
E
The controller system device is only connected to the
node through a single target port.
1627
010042
E
The controller system device is only connected to the
cluster (system) nodes through a single target port.
1627
010043
E
The controller system device is only connected to the
cluster (system) nodes through half of the expected
target ports.
1627
010044
E
The controller system device has disconnected all target
ports to the cluster (system) nodes.
1627
010050
W
A solid-state drive (SSD) failed. A rebuild is required.
1201
010051
E
A solid-state drive (SSD) is missing.
1202
010052
E
A solid-state drive (SSD) is offline as a result of a drive
hardware error.
1205
010053
E
A solid-state drive (SSD) is reporting a predictive failure
analysis (PFA).
1215
010054
E
A solid-state drive (SSD) is reporting too many errors.
1215
010055
W
An unrecognized SAS device.
1665
010056
E
SAS error counts exceeded the warning thresholds.
1216
010057
E
SAS errors exceeded critical thresholds.
1216
010058
E
The drive initialization failed because of an unknown
block size or a block size that is not valid; an unknown
capacity or a capacity that is not valid; or was not able to
set the required mode pages.
1661
010059
E
A solid-state drive (SSD) is offline due to excessive
errors.
1311
122
Storwize V7000: Troubleshooting, Recovery, and Maintenance Guide
Содержание Storwize V7000
Страница 1: ...IBM Storwize V7000 Version 6 3 0 Troubleshooting Recovery and Maintenance Guide GC27 2291 02...
Страница 6: ...vi Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 8: ...viii Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 10: ...x Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 34: ...18 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 42: ...26 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 80: ...64 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 128: ...112 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 156: ...140 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 166: ...150 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 171: ......
Страница 172: ...Printed in USA GC27 2291 02...