5.
From one side of the rack cabinet, grip the rail and slide the rail pieces
together to shorten the rail.
6.
Disengage the rail location pins
2
.
7.
From the other side the rack cabinet, grip the rail and slide the rail pieces
together to shorten the rail.
8.
Disengage the rail location pins
2
.
9.
Starting from the location of the previous rail assembly, align the bottom of
the rail with the bottom of the two rack units. Insert the rail location pins
through the holes in the rack cabinet.
10.
Insert a clamping screw into the upper mounting hole between the rail
location pins.
11.
Tighten the screw to secure the rail to the rack.
12.
Working from the rear of the rack cabinet, extend the rail that you secured to
the front to align the bottom of the rail with the bottom of the two rack units.
Note:
Ensure that the rail is level between the front and the back.
13.
Insert the rail location pins through the holes in the rack cabinet.
14.
Insert a clamping screw into the upper mounting hole between the rail
location pins.
15.
Tighten the screw to secure the rail to the rack from the back side.
16.
Repeat the steps to secure the opposite rail to the rack cabinet.
Storwize V7000 replaceable units
TheStorwize V7000 consists of several replaceable units. Generic replaceable units
are cables, SFP transceivers, canisters, power supply units, battery assemblies, and
enclosure chassis.
Table 22 provides a brief description of each replaceable unit.
Table 22. Replaceable units
Part
Part number
Applicable
models
FRU or customer
replaced
2U24 enclosure chassis (empty
chassis)
85Y5897
124, 224, 324
FRU
2U12 enclosure chassis (empty
chassis)
85Y5896
112, 212, 312
FRU
Type 100 node canister
85Y5899
112, 124
Customer
replaced
Type 300 node canister with 10
Gbps Ethernet ports
85Y6116
312, 324
Customer
replaced
Expansion canister
85Y5850
212, 224
Customer
replaced
764 W power supply unit
85Y5847
112, 124, 312, 324 Customer
replaced
580 W power supply unit
85Y5846
212, 224
Customer
replaced
Battery backup unit
85Y5898
112, 124, 312, 324 Customer
replaced
1 m SAS cable
44V4041
212, 224
Customer
replaced
Chapter 8. Removing and replacing parts
109
|
Содержание Storwize V7000
Страница 1: ...IBM Storwize V7000 Version 6 3 0 Troubleshooting Recovery and Maintenance Guide GC27 2291 02...
Страница 6: ...vi Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 8: ...viii Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 10: ...x Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 34: ...18 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 42: ...26 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 80: ...64 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 128: ...112 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 156: ...140 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 166: ...150 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 171: ......
Страница 172: ...Printed in USA GC27 2291 02...