Installation and Commissioning

Rev. 1.0.2 / 080618

English

Storage Extension

for DAS-303

DAS-300 E

Содержание DAS-300 E

Страница 1: ...Installation and Commissioning Rev 1 0 2 080618 English Storage Extension for DAS 303 DAS 300 E...

Страница 2: ...for those not caused by intention or gross neglegence of the manufacturer Dallmeier electronic GmbH Co KG Cranachweg 1 D 93051 Regensburg www dallmeier electronic com info dallmeier electronic com Ad...

Страница 3: ...Power supply module 14 5 2 3 Fan module 14 5 2 4 Disk I O module 15 6 Mounting 16 6 1 Safety requirements 16 6 2 Installation requirements 16 6 3 Attaching the chassis slides 17 6 4 Attaching the guid...

Страница 4: ...ng the I O module 28 9 4 1 Removing the I O module 28 9 4 2 Installing the I O module 29 9 4 3 Restart after I O module replacement 29 9 5 Dummy module 29 10 Maintenance and cleaning 30 10 1 Maintenan...

Страница 5: ...1 3 Convention This document contains various warning words and symbols that indicate potential sources of danger Various symbols and formats are used to maintain the clarity of the document DANGER T...

Страница 6: ...e LC LC HDD Hard drive disk HDD module HDD removable drive enclosure Hot plug Hot plugging is the ability to replace hardware of a unit while the unit is operating Fan module Replaceable fan Sub rack...

Страница 7: ...bject to data protection The collecting recording processing or disclosure of such data may be forbidden and thus have legal consequences Therefore inform yourself on data protection laws and regulati...

Страница 8: ...open the unit Do not open the housing of the unit There are no components inside the unit that require maintenance by the user The inspection maintenance and repair with an open housing must only be...

Страница 9: ...mproper transportation The goods should only be shipped in their original packaging If the original packaging is no longer available ensure that the packaging used sufficiently protects the unit again...

Страница 10: ...ications were in effect for the DAS 300 E at the time this document was produced z CCC z BSMI z CE z UL z cUL z RoHS R5 z Microsoft WHQL z Microsoft RAID System Submission w MPIO Single Host 3 6 Warra...

Страница 11: ...ton 4 status LEDs and 12 bays for 12 HDD modules 1 Alarm Mute push button 4 status LEDs 2 HDD module 4 2 Rear view The DAS 300 E back panel provides 5 bays for 2 power supply modules 1 fan module and...

Страница 12: ...odule The DAS 300 E must never be operated with one or more unfitted bays for more than a few minutes since this may cause overheating of the DAS 300 E and thus power failure and data loss IMPORTANT S...

Страница 13: ...ured against accidentally opening by locking the integrated anti tamper lock Two LEDs on the front side indicate the status of each HDD module LED green off on blink on on off LED amber off off off of...

Страница 14: ...ys be operated with 2 power supply modules installed Two LEDs on the rear side indicate the status of each power supply module 5 2 3 Fan module The DAS 300 E is equipped with a fan module for monitori...

Страница 15: ...s designed to be equipped with one Disk I O module DAS 303 and DAS 300 E are connected together via SAS cables 1 RS 323 2 Host IN Port 3 Host IN Port LEDs 4 Factory Use Only 5 Host OUT Port 6 Host OUT...

Страница 16: ...pply in each unit has an earth leakage current of 1 5 mA maximum at 264 V AC The design of the electrical distribution system must take into consideration the total earth leakage current from all the...

Страница 17: ...t be at the bottom 6 4 Attaching the guide rails 1 If necessary loosen both clamping screws to change the length of the guide rails before attaching them 2 Fit the guide rails into the rack 3 Attach t...

Страница 18: ...t the DAS 300 E and insert the chassis slides into the guide rails 2 Completely slide the DAS 300 E into the rack IMPORTANT Possible damage to the DAS 300 E and or rack Ensure that you slide it straig...

Страница 19: ...a DAS 300E 1 Shut down the recorder 2 Turn off the recorder 3 Disconnect the recorder from the power supply pull out the power plug 4 Disconnect the DAS 303 from the power supply 5 Connect the DAS 30...

Страница 20: ...DAS 300 E 20 Dallmeier electronic Connection of four DAS 300 E to the DAS 303 The DAS 303 is connected to two recorders DAS 303 Recorder 1 DAS 300 E DAS 300 E DAS 300 E DAS 300 E Recorder 2 Fig 7 2...

Страница 21: ...is commissioned as part of a storage system Thereby the following starting order must be observed NOTE Supply the storage system using a programmable socket strip in order to ensure the starting order...

Страница 22: ...n replacing an HDD However the following conditions must be paid attention to due to unit and data safety reasons CAUTION The following conditions must always be taken into account when changing an HD...

Страница 23: ...Contact the Dallmeier Support Team if you are in any doubt 9 1 2 Removing the HDD module IMPORTANT Possible damage to the RAID system and thus loss of data Never remove more than one HDD module in th...

Страница 24: ...Ensure that the module handle is released and insert the HDD module into the bay 3 Carefully slide the module into the bay until you encounter resistance IMPORTANT Possible damage to the HDD module a...

Страница 25: ...aulty power supply module must be replaced within 24 hours NOTE Do not mix power supply modules of different types or makes 9 2 1 Removing the power supply module NOTE The power supply module replacem...

Страница 26: ...y module WARNING Danger of death from electric shock Only connect the non heating appliance cable to the power supply module after sliding the module in 1 Ensure that the power supply module is correc...

Страница 27: ...ctric shock Do not reach into the open housing of the sub rack Do not insert any objects 9 3 2 Installing the fan module 1 Ensure that the fan module is correctly aligned The plug strip must be at the...

Страница 28: ...er 2 Disconnect both power packs of the DAS 300 E from the power supply 3 Using two hands grasp each handle between the thumb and forefinger of each hand Squeeze thumb and forefinger together to relea...

Страница 29: ...both handles of the I O module A click should be heard as the handles engage 9 4 3 Restart after I O module replacement 1 Connect both power packs to the power supply The Power on LED will be lit gre...

Страница 30: ...kind is required if the DAS 300 E is used as specified 10 2 Cleaning If the housing of the DAS 300 E is soiled use a dry cleaning cloth to clean it IMPORTANT Possible damage caused by cleansing agents...

Страница 31: ...controller RAID Levels 0 1 5 10 50 RAID Controller Hot plug Power supply Hot plug Yes redundant HDDs Hot plug Yes Ventilator Hot plug Yes redundant Further specifications Interfaces 2 x 3Gb s SAS in...

Страница 32: ...G and the Council Directive relating to Low Voltage 73 23 EWG The following company is responsible for this declaration Dallmeier electronic GmbH Co KG Cranachweg 1 D 93051 Regensburg The measurements...