Ethernet Controller Messages
PCNTNW-OS2-61 PCI device IRQ number mismatch.
Explanation:
The IRQ number specified in the NET.CFG file does not match with
the IRQ number assigned in the configuration programs. The IRQ numbers might be
assigned automatically, or you might have manually assigned the IRQ number.
Action:
Remove the IRQ number in the NET.CFG file. Or, see “PCI Routing” on
page 94 for information on setting the interrupt requests.
PCNTNW-OS2-64 The device was not found.
Explanation:
The driver cannot find the Ethernet contoller in the server.
Action:
Verify that the Ethernet enable jumper is set to the default (enable) position.
Go to “About the Test Programs” on page 233 to run the diagnostic utility.
PCNTNW-OS2-65 Device not found at IOADDRESS.
Explanation:
The Ethernet controller cannot be found at the IO address specified in
the NET.CFG file.
Action:
Verify that the IO address in NET.CFG matches with the board. Otherwise,
remove the PORT keyword from the NET.CFG file.
PCNTNW-OS2-67 PCI scan specified, device not found.
Explanation:
The driver cannot locate the Ethernet controller on the PCI bus.
Action:
Perform the following steps:
1. Verify that the Ethernet jumper on the system board is set to the default, enable
position.
2. Edit the NET.CFG file to change the BUSTYPE keyword to PCI1.
3. If the problem persists, go to “About the Test Programs” on page 233 to run the
diagnostic utility.
PCNTNW-OS2-73 Unable to allocate memory.
Explanation:
The driver could not allocate memory for the virtual board.
Action:
Check the system configuration.
PCNTNW-OS2-80 The DMA parameter is not necessary to PCI device.
Explanation:
The Ethernet controller does not require a DMA setting. This
parameter is not a valid driver parameter. The PCI system BIOS automatically sets
the DMA channel number.
Action:
Edit the NET.CFG file to delete the DMA parameter.
270
PC Server 330 User's Handbook
Содержание PC Server 330
Страница 1: ...PC Server 330 User s Handbook IBM...
Страница 6: ...vi PC Server 330 User s Handbook...
Страница 10: ...x PC Server 330 User s Handbook...
Страница 32: ...18 PC Server 330 User s Handbook...
Страница 100: ...86 PC Server 330 User s Handbook...
Страница 134: ...120 PC Server 330 User s Handbook...
Страница 143: ...Preparing to Add Options 11 Remove the adapter retention bracket Chapter 4 Installing Options 129...
Страница 233: ...Completing the Installation 2 Reinstall the adapter retention bracket Slot Chapter 4 Installing Options 219...
Страница 240: ...Updating the Server Configuration 226 PC Server 330 User s Handbook...
Страница 326: ...Resolving Configuration Conflicts 312 PC Server 330 User s Handbook...
Страница 382: ...IBM Part Number 76H8834 Printed in U S A September 1996 76H8834...