Ethernet Controller Messages
PCNTNW-DOS-19 An invalid Ethernet node address is specified in NET.CFG. The
MLID modified the incorrect address bits.
Explanation:
The NET.CFG file has an invalid node address. The PCNTNW MLID
modified and corrected the address.
Action:
Verify the node address entries in the NET.CFG file.
PCNTNW-DOS-50 The board cannot be found.
Explanation:
The Ethernet controller is either not configured correctly or is disabled.
Action:
Perform the following steps:
1. Verify that the Ethernet jumper on the system board is set to the default, enabled
position.
2. Check the settings for the Ethernet controller (for example, the I/O and interrupt
request settings) against the settings in the NET.CFG. See “PCI Routing” on
page 94 for information on setting the interrupt requests.
3. If the problem persists, go to “About the Test Programs” on page 233 to run the
diagnostic utility.
PCNTNW-DOS-54 The board did not respond to the initialization command.
Explanation:
The Ethernet controller initialization failed.
Action:
Verify that the Ethernet jumper on the system board is set to the default,
enabled position. Go to “About the Test Programs” on page 233 to run the
diagnostic utility.
PCNTNW-DOS-58 The board did not respond to the initialization command.
Explanation:
The IRQ setting might be incorrect with the hardware setting, or the
EEPROM might be corrupted.
Action:
Verify that the IRQ settings in the NET.CFG file match the configuration
settings in the configuration programs. See “PCI Routing” on page 94 for
information on setting the interrupt requests. Verify that the EEPROM on the system
board is programmed correctly.
PCNTNW-DOS-61 PCI device IRQ number mismatch.
Explanation:
The IRQ number specified in the NET.CFG file does not match with
the IRQ number assigned in the configuration programs.
Action:
Remove the IRQ number in the NET.CFG file.
Chapter 5. Solving Problems
267
Содержание PC Server 330
Страница 1: ...PC Server 330 User s Handbook IBM...
Страница 6: ...vi PC Server 330 User s Handbook...
Страница 10: ...x PC Server 330 User s Handbook...
Страница 32: ...18 PC Server 330 User s Handbook...
Страница 100: ...86 PC Server 330 User s Handbook...
Страница 134: ...120 PC Server 330 User s Handbook...
Страница 143: ...Preparing to Add Options 11 Remove the adapter retention bracket Chapter 4 Installing Options 129...
Страница 233: ...Completing the Installation 2 Reinstall the adapter retention bracket Slot Chapter 4 Installing Options 219...
Страница 240: ...Updating the Server Configuration 226 PC Server 330 User s Handbook...
Страница 326: ...Resolving Configuration Conflicts 312 PC Server 330 User s Handbook...
Страница 382: ...IBM Part Number 76H8834 Printed in U S A September 1996 76H8834...