SSSS-102
Explanation:
An unrecoverable media error occurred.
1.
Check the BladeCenter
⌂⌂
management-module event log. If an error was recorded by the system, see POST
progress codes (checkpoints).
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in Replacing the system-board and chassis assembly.
Response:
Failing Item:
v
SSSS-104
Explanation:
The motor failed to restart.
1.
Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in Replacing the system-board and chassis assembly.
Response:
Failing Item:
v
SSSS-105
Explanation:
The drive did not become ready.
1.
Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in Replacing the system-board and chassis assembly.
Response:
Failing Item:
v
SSSS-106
Explanation:
The electronics card test failed.
1.
Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in Replacing the system-board and chassis assembly.
Response:
Failing Item:
v
SSSS-102 • SSSS-106
Chapter 8. Troubleshooting
439
Содержание P260
Страница 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 523: ...Appendix Notices 511 ...
Страница 524: ...IBM Printed in USA ...