2E53-605
Explanation:
Ethernet hardware error. Replace the PCIe2 10Gb 8-port FCoe Mezzanine Adapter
Response:
Failing Item:
v
2E53-606
Explanation:
Ethernet configuration error Replace the PCIe2 10Gb 8-port FCoe Mezzanine Adapter
Response:
Failing Item:
v
2E53-607
Explanation:
Ethernet EEH error. Replace the PCIe2 10Gb 8-port FCoe Mezzanine Adapter
Response:
Failing Item:
v
803-XXXX
Explanation:
A software error occurred while running the diagnostics which could be caused by either hardware or
software.
Response:
Note: This SRN can also occur if the filesystem is full, particularly in the / , /var , or /tmp directories
(verify using the df command at the AIX prompt, make sure %Used is 90% or less for each file system). Run
standalone diagnostics. If you get a different SRN, use it in place of the original SRN. If you get the same SRN, use
the last three or four digits of the 803-xxx(x) as the FRU and use general problem resolution. If you get no error from
the standalone diagnostics, you may have a problem with the software, contact your support center. Note: xxxx
corresponds to the last three or four digits of the SRN. If your 803-xxx(x) SRN is not listed, substitute the last three or
four digits of the SRN after the dash (-) for xxx(x) , then proceed to the FRU list using the substituted digits as your
FRU.
950-2506
Explanation:
Missing options resolution for 3Gb SAS Adapter card.
Try each of the following steps. After reseating, removing, or replacing a part, retry the operation.
1.
Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2.
Replace any parts reported by the diagnostic program.
3.
Reseat the 3Gb SAS Adapter card.
4.
Replace the 3Gb SAS Adapter card.
5.
Replace the system-board
Response:
Failing Item:
v
v
2E53-605 • 950-2506
Chapter 8. Troubleshooting
409
Содержание P260
Страница 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 523: ...Appendix Notices 511 ...
Страница 524: ...IBM Printed in USA ...