B7005120
Explanation:
System firmware detected an error
Response:
If the system is not exhibiting problematic behavior, you can ignore this error. Otherwise, go to Isolating
B7005121
Explanation:
System firmware detected a programming problem for which a platform dump may have been
initiated.
Response:
1.
Collect the event log information.
2.
Collect the platform dump information.
3.
Go to Isolating firmware problems.
B7005122
Explanation:
An error occurred during a search for the load source.
Response:
If the partition fails to startup, go to Isolating firmware problems. Otherwise, no corrective action is
required.
B7005123
Explanation:
Informational system log entry only.
Response:
No corrective action is required.
B7005190
Explanation:
Operating system error. The server firmware detected a problem in an operating system.
Response:
Check for error codes in the partition that is reporting the error and take the appropriate actions for
those error codes.
B7005191
Explanation:
System firmware detected a virtual I/O configuration error.
Response:
1.
Use the management console to verify or reconfigure the invalid virtual I/O configuration.
2.
Check for server firmware updates; then, install the updates if available.
B7005120 • B7005191
176
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide
Содержание P260
Страница 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 523: ...Appendix Notices 511 ...
Страница 524: ...IBM Printed in USA ...