Table 20. Hypervisor isolation procedures and symbolic failing items (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 7, “Parts listing for IBM Flex System p260 and p460 Compute Nodes,” on page 97 to determine
which components are CRUs and which components are FRUs.
v
If an action step is preceded by Trained service technician only, that step must be performed only by a trained
service technician.
Isolation
procedure or
symbolic failing
item
Symptom
Action
CAPACTY
The failing
component is the
management card.
1.
Replace the management card, as described in “Removing the
management card” on page 73 and “Installing the management card”
on page 75.
2.
After replacing the card and installing the compute node in the
chassis unit and before rebooting the compute node or performing
other operations, ensure that the initialization of the VPD on the
management card occurs by waiting for the management module to
discover the compute node. Otherwise, the system might fail to
perform an initial program load (IPL).
CLCKMOD
The logic oscillator is
failing.
Replace the system-board and chassis assembly, as described in
“Replacing the system-board and chassis assembly” on page 83.
FRPORT
This item does not apply to compute nodes. Continue with the next item in the failing item list.
HEA
This item does not apply to compute nodes. Continue with the next item in the failing item list.
HSL_LNK
This item does not apply to compute nodes. Continue with the next item in the failing item list.
LICCODE
A firmware problem
occurred.
See Isolating firmware problems.
LPARCFG
There is a
configuration
problem with the
system or with a
logical partition.
1.
Perform all actions associated with the other failing items logged
with this System reference code (SRC). If that does not resolve the
problem, continue with the next step.
2.
Check processor and memory allocations of the system or the
partitions.
Verify that the processor and memory have enough functioning
resources in the system for all of the partitions. Processor or memory
have enough functioning resources that failed or were removed
during system power on could cause the problem in the partition.
3.
Check the bus and I/O adapter allocations for the partition.
Verify that the partition has load source and console I/O resources.
4.
Check the IPL mode of the system or failing partition.
5.
For further assistance, contact IBM Support.
LSERROR
An error occurred
when the platform
Licensed Internal
Code attempted to
locate the partition's
load source.
Choose from the following options:
v
If the load source is a disk drive or solid-state drive, perform a
D-mode IPL. Correct any errors found.
v
If the load source is not a disk drive or solid-state drive, replace the
media. If replacing the media does not work, look for other errors.
MA_BRDG
The multi-adapter
bridge hardware is
failing.
Replace the system-board and chassis assembly, as described in
“Replacing the system-board and chassis assembly” on page 83.
MABIP50
This item does not apply to compute nodes. Continue with the next item in the failing item list.
MABIP51
This item does not apply to compute nodes. Continue with the next item in the failing item list.
464
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide
Содержание P260
Страница 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 523: ...Appendix Notices 511 ...
Страница 524: ...IBM Printed in USA ...