651-199
Explanation:
This is a test of the flow of a serviceable event from this system to management console. This is not a
real problem.
Response:
Problem determination:
Use the management console to list serviceable events and verify the serviceable event was
sent to the HMC.
652-600
Explanation:
A non-critical error has been detected: uncorrectable memory or unsupported memory. Schedule
deferred maintenance. Examine the memory modules and determine if they are supported types. If the modules are
supported, then replace the appropriate memory modules.
Response:
652-610
Explanation:
A non-critical error has been detected: CPU internal error. Schedule deferred maintenance. Go to
Performing the checkout procedure.
Response:
Failing Item:
v
652-611
Explanation:
A non-critical error has been detected: CPU internal cache or cache controller error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v
652-612
Explanation:
A non-critical error has been detected: external cache parity or multi-bit ECC error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v
651-199 • 652-612
310
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide
Содержание P260
Страница 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 523: ...Appendix Notices 511 ...
Страница 524: ...IBM Printed in USA ...