Table 13. Mapping network adapter ports to IBM Flex System Enterprise Chassis I/O bays for the IBM Flex System
p460 Compute Node (continued)
Port location
code
IBM Flex
System 2-port
QDR
InfiniBand
adapter
IBM Flex
System 2-port
10 Gb RoCE
adapter
IBM Flex
System 2-port
8 Gb and
2-port 16 Gb
Fibre Channel
adapter
IBM Flex
System 4-port
16 Gb Fibre
Channel
adapter
IBM Flex
System 4-port
1 Gb Ethernet
and 4-port 10
Gb Ethernet
adapters
IBM Flex
System 8-port
10 Gb
converged
adapter
Un-P1-C37-L1-
T1
Chassis I/O
bay 3
Chassis I/O
bay 3
Chassis I/O
bay 3
Chassis I/O
bay 3
Chassis I/O
bay 3
Chassis I/O
bay 3
Un-P1-C37-L1-
T2
Chassis I/O
bay 4
Chassis I/O
bay 4
Chassis I/O
bay 4
Chassis I/O
bay 4
Un-P1-C37-L1-
T3
Chassis I/O
bay 3
Un-P1-C37-L1-
T4
Chassis I/O
bay 4
Un-P1-C37-L2-
T1
Chassis I/O
bay 4
Chassis I/O
bay 4
Chassis I/O
bay 3
Chassis I/O
bay 3
Chassis I/O
bay 3
Un-P1-C37-L2-
T2
Chassis I/O
bay 4
Chassis I/O
bay 4
Chassis I/O
bay 4
Un-P1-C37-L2-
T3*
Chassis I/O
bay 3
Un-P1-C37-L2-
T4*
Chassis I/O
bay 4
For more information about port mapping, see http://publib.boulder.ibm.com/infocenter/flexsys/information/
topic/com.ibm.acc.8721.doc/configuring_io_modules.html.
* Ports L2-T3 and L2-T4 require switches that have the capability of 56 internal ports.
Reference codes
Reference codes are diagnostic aids that help you determine the source of a hardware or operating
system problem. To use reference codes effectively, use them in conjunction with other service and
support procedures.
The IBM Flex System p260 Compute Node or IBM Flex System p460 Compute Node produces several
types of codes.
Progress codes:
The power-on self-test (POST) generates eight-digit status codes that are known as
checkpoints or progress codes, which are recorded in the management-module event log. The checkpoints
indicate which compute node resource is initializing.
Error codes:
The First Failure Data Capture (FFDC) error checkers capture fault data, which the service
processor then analyzes. For unrecoverable errors (UEs), for recoverable events that meet or exceed their
service thresholds, and for fatal system errors, an unrecoverable checkstop service event triggers the
service processor to analyze the error, log the system reference code (SRC), and turn on the system
attention LED.
The service processor logs the nine-word, eight-digit per word error code in the IBM Flex System
Enterprise Chassis management-module event log. Error codes are either system reference codes (SRCs) or
service request numbers (SRNs). A location code might also be included.
Chapter 8. Troubleshooting
115
Содержание P260
Страница 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 523: ...Appendix Notices 511 ...
Страница 524: ...IBM Printed in USA ...