BA010003
Explanation:
Cannot get server hardware address
Response:
Perform the following actions that checkpoint CA00E174 describes:
1.
Verify that:
v
The bootp server is correctly configured; then, retry the operation.
v
The network connections are correct; then, retry the operation.
2.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA010004
Explanation:
Bootp failed
Response:
Perform the following actions that checkpoint CA00E174 describes:
1.
Verify that:
v
The bootp server is correctly configured; then, retry the operation.
v
The network connections are correct; then, retry the operation.
2.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA010005
Explanation:
File transmission (TFTP) failed
Response:
Perform the following actions that checkpoint CA00E174 describes:
1.
Verify that:
v
The bootp server is correctly configured; then, retry the operation.
v
The network connections are correct; then, retry the operation.
2.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA010006
Explanation:
The boot image is too large
Response:
Start up from another device with a bootable image.
BA010007
Explanation:
The device does not have the required device_type property.
Response:
1.
Reboot the server.
2.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA010003 • BA010007
Chapter 8. Troubleshooting
195
Содержание P260
Страница 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 523: ...Appendix Notices 511 ...
Страница 524: ...IBM Printed in USA ...