BA340005
Explanation:
An internal firmware error occurred; the location code mapping table was corrupted.
Response:
1.
Reboot the server.
2.
Check for server firmware updates; install the updates if available.
3.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA340006
Explanation:
An LP (logical partition) event communication failure occurred reading the system initiator capability
data from the service processor.
Response:
1.
Reboot the server.
2.
Check for server firmware updates; install the updates if available.
3.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA340007
Explanation:
An internal firmware error occurred; the open fabric manager system initiator capability data was
corrupted.
Response:
1.
Reboot the server.
2.
Check for server firmware updates; install the updates if available.
3.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA340008
Explanation:
An internal firmware error occurred; the open fabric manager system initiator capability data version
was not correct.
Response:
1.
Reboot the server.
2.
Check for server firmware updates; install the updates if available.
3.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA340005 • BA340008
Chapter 8. Troubleshooting
231
Содержание P260
Страница 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 523: ...Appendix Notices 511 ...
Страница 524: ...IBM Printed in USA ...