BA060021
Explanation:
The environment variable boot-device contained more than five entries.
Response:
1.
Reboot the server.
2.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA060022
Explanation:
The environment variable boot-device contained an entry that exceeded 255 characters in length
Response:
1.
Using the SMS menus, set the boot list to the default boot list.
2.
Shut down, then restart the server.
3.
Use the SMS menus to customize the boot list as required.
4.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA060030
Explanation:
Logical partitioning with shared processors is enabled and the operating system does not support it.
Response:
1.
Install or boot a level of the operating system that supports shared processors.
2.
Disable logical partitioning with shared processors in the operating system.
3.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA060060
Explanation:
The operating system expects an IOSP partition, but it failed to make the transition to alpha mode.
Response:
1.
Verify that:
v
The alpha-mode operating system image is intended for this partition.
v
The configuration of the partition supports an alpha-mode operating system.
2.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA060021 • BA060060
206
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide
Содержание P260
Страница 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 523: ...Appendix Notices 511 ...
Страница 524: ...IBM Printed in USA ...