BA060061
Explanation:
The operating system expects a non-IOSP partition, but it failed to make the transition to MGC mode.
Response:
1.
Verify that:
v
The alpha-mode operating system image is intended for this partition.
v
The configuration of the partition supports an alpha-mode operating system.
2.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA060070
Explanation:
The operating system does not support this system's processor(s)
Response:
Boot a supported version of the operating system.
BA060071
Explanation:
An invalid number of vectors was received from the operating system
Response:
Boot a supported version of the operating system.
BA060072
Explanation:
Client-arch-support hcall error
Response:
1.
Reboot the server.
2.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA060075
Explanation:
Client-arch-support firmware error
Response:
1.
Reboot the server.
2.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA060200
Explanation:
Failed to set the operating system boot list from the management module boot list
Response:
1.
Using the SMS menus, set the boot list to the default boot list.
2.
Shut down, then restart the server.
3.
Use SMS menus to customize the boot list as required.
4.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA060061 • BA060200
Chapter 8. Troubleshooting
207
Содержание P260
Страница 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 523: ...Appendix Notices 511 ...
Страница 524: ...IBM Printed in USA ...