Note:
See “System” on page 116 to determine which components should be replaced by a field service technician.
AC good LED
DC good LED
Description
FRU/action
On
Off
Standby mode or dc
problem.
1.
Check system board cable connectors
J4 and J10.
Move switch 3 of SW 1 to
bypass power control. If the dc good LED
is lit, press Ctrl+Alt+Delete. Watch the
screen for any POST errors. Check the
System Error Log for any listed problems. If
the system starts with no errors:
a. Power switch assembly
b. System board
2. Remove the adapters and disconnect the
cables and power connectors to all internal
and external devices. Turn on the system.
If the dc good LED is lit, replace the
adapters and devices one at a time until
you isolate the problem.
3. Power supply.
4. Power cage assembly.
5. System board.
On
On
Power is working properly.
N/A
POST error codes
In the following error codes,
X
can be any number or letter.
Note:
See “System” on page 116 to determine which components should be replaced by a field service technician.
Error code/symptom
FRU/action
062
(Three consecutive startup failures using
the default configuration.)
1.
Run the Configuration/Setup Utility program.
2. Battery.
3. System board.
4. Microprocessor.
101, 102
(System and processor error)
v
System board
106
(System and processor error)
v
System board
111
(Channel check error)
1.
Memory DIMM
2. System board
114
(Adapter read-only memory error)
1.
Failing adapter.
2. Run diagnostics.
129
(Internal cache error)
1.
Microprocessor
2. Optional microprocessor (if installed)
151
(Real time clock error)
1.
Run diagnostics.
2. Battery.
3. System board.
161
(Real time clock battery error)
1.
Run the Configuration/Setup Utility program.
2. Battery.
3. System board.
Chapter 6. Symptom-to-FRU index
101
Содержание eServer xSeries 345 Type 8670
Страница 1: ...xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Страница 2: ......
Страница 3: ...xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Страница 6: ...iv xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 10: ...viii xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 18: ...8 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 88: ...78 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 124: ...114 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 130: ...120 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 141: ...Chapter 8 Related service information 131...
Страница 142: ...132 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 143: ...Chapter 8 Related service information 133...
Страница 144: ...134 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 145: ...Chapter 8 Related service information 135...
Страница 146: ...136 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 147: ...Chapter 8 Related service information 137...
Страница 157: ...Chapter 8 Related service information 147...
Страница 158: ...148 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 159: ...Chapter 8 Related service information 149...
Страница 160: ...150 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 161: ...Chapter 8 Related service information 151...
Страница 162: ...152 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 166: ...156 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 174: ...164 xSeries 345 Type 8670 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 175: ......
Страница 176: ...Part Number 48P9718 1P P N 48P9718...