232
Country-Specific Considerations: Europe, Mid-East,
Africa, Asia Pacific, parts of Latin America
1. Device to Rack PDU power cable
IEC C13 to C14, 10/15a cable
typical: P/N 36L8886 (2.8m)
requirement: C14 plug, long enough to reach
available option: 94G7448 (14ft)
2. Rack PDU to wall line cord
IEC C19 to country-specific connector,
16/20a, 14ft (4.3m)
3. Rack PDU to UPS power cable
IEC C19 to C20, 16/20a
P/N 00N7700 (2m)
provided with P/N 37L6861 (APC SU-5000RMB)
4. Rack PDU to Front-end PDU power cable
IEC C19 to C20, 16/20a
P/N 00N7698 (1m)
provided with the Front-end PDUs
5. Front-end PDU to wall line cord
special to country-specific connector,
30/32a, 8.2ft (2.5m)
Power Cables:
(2) Line Cords: Rack PDUs
(5) Line Cords: Front-end PDUs
Part
Number
Plug Type
Source Circuit (single
phase 50/60Hz)
PDU Output
(single phase 50/60Hz)
37L6866
NEMA L5-20P
100-127Vac, 20a
seven 100-127Vac, shared 15a
NEMA L6-20P
200-240Vac, 20a
seven 220-240Vac, shared 15a
37L6868
CEE7-VII
220-240Vac, 16a
37L6870
IEC 309-2P+Gnd
220-240Vac, 16a
37L6872
SII 32
220-240Vac, 16a
37L6874
CEI 23-16
220-240Vac, 16a
37L6876
SABS 164
220-240Vac, 16a
06P6028
BS 1363/A220-240Vac, 13a
37L6864
country-specific line
cord provided by IBM
country specific
seven 220-240Vac, shared 13a
Part
Number
Plug Type
Source Circuit (50/
60Hz)
PDU Output
(single phase 50/60Hz)
37L6883
NEMA L5-30P
100-127Vac, 30a, single-phase
three 100-127Vac, 20a each, shared
30a
37L6884
NEMA L6-30P
200-240Vac, 30a, single phase
line-to-line with ground
three 200-240Vac, shared 24a
37L6886
NEMA L21-30P
200-250Vac, 30a, three-phase
Y-connection with neutral
three 100-127Vac (115-145), 20a
each, shared 41a
37L6885
IEC 309-2P+Gnd
220-240Vac, 32a, single-phase
three 220-240Vac, 16a each,
shared 32a
37L6887
IEC 309-3P+N+Gnd
380-415Vac, 32a, three-phase
Y-connection with neutral
three 220-240Vac, 16a each
Power Load Capacity -- xSeries / Netfinity Rack Systems
220V
230V
235V
240V
3525W
3450W
3300W
3600W
220V
230V
235V
240V
3525W
3450W
3300W
3600W
220V
230V
235V
240V
3525W
3450W
3300W
3600W
220V
230V
235V
240V
2506W
2453W
2346W
2560W
C
C
C
C
220V
230V
235V
240V
2506W
2453W
2346W
2560W
220V
230V
235V
240V
2506W
2453W
2346W
2560W
C
C
220V
230V
235V
240V
3525W
3450W
3300W
3600W
7040W 7360W 7620W 7680W
220V
240V
235V
230V
9900W
10350W 10575W 10800W
220V
240V
235V
230V
C
@ country specific:
IEC 309-2P+G
CEE7-VII
SII 32
SABS 164
BS 1363 w/fuse
CEI 23-16
etc.
W
W
220-240Vac
1 phase
16a
220-240Vac
1 phase
32a
380-415Vac
3 phase
32a
w/neutral
various @
309-2P+G
309-3P+N+G
shared 32a
NOTE:
C = Rack PDU with a 15a circuit breaker
W = FE PDU with a 20a fuse per outlet
1 ph
3 ph
NOTE: Actual power values (watts) may
vary based on actual source voltage.
Содержание 6219 - IntelliStation M - Pro
Страница 179: ...Updated 02 Dec 02 141B...
Страница 243: ...BladeCenter HS20 this page intentionally blank this page intentionally blank Updated 02 Dec 02 191B...
Страница 273: ...IBM Rack Cabinets and Options this page intentionally blank this page intentionally blank Updated 02 Dec 02 217B...
Страница 282: ...226 Refer to the cable labeling key in the Cable Options table appearing later in this section...
Страница 283: ...227...