Power Supply Options
Standard Power
Cords
Power Supply
Part Number
Usable with
6f
t
N
E
M
A
5
-15P
P
/N
695
230
1
9f
t
N
E
M
A
5
-15P
P
/N
695
2300
6f
t
N
E
M
A
6
-15P
P
/N
183
85
7
6
9f
t
IE
C
3
2
0
-C
1
4
P
/N
36L8886
110w
09L5403
2109-S08, 16
1
126w
18P3576
2109-F16
1
250w
33L3760
x250
1
350w
59P4057
x345
1
370w
31P6108
x360, RXE-100
1
1
370w
31P6133
x255
11
560w
33P2753
x235
12
2
1200w
48P7052
BladeCenter
2
1. Requires 4Ux20D Tower-to-Rack Kit (P/N 09N4300) to mount server unit into an EIA rack cabinet.
2. Requires 4U Extended Depth Tower to Rack Conversion Kit (P/N 59P4817) to mount server unit into an EIA rack cabinet.
3. Requires 5Ux24D Tower-to-Rack Kit III (P/N 59P4211) to mount server unit into an EIA rack cabinet. Models are available
with both a single 560w power supply and two hot-swap 560w power supplies.
4. Tower models require 7Ux26D Tower-to-Rack Kit (P/N 32P1474) to mount server unit into an EIA rack cabinet.
5. To provide adequate cooling, blank filler panel kit (P/N 94G6670) should be placed on the front of any unused rack space.
If non-IBM racks are to be used, assure that both front and rear doors offer a minimum of 48% open area uniformly distributed
and in line with installed servers. A clearance of 51 to 64mm (2 to 2.5in) must be maintained between the front of the door and
the system unit’s front bezel. The rear door must maintain the same or greater clearance. Nonrack or NetBAY3 installations
are not supported.
6. x370 requires installation of extension kit (P/N 36L9703 or 36L9702) when installed in a 9306-900, 910 or 9306-200,
respectively, for proper rear door clearance.
7. Internal power supply logic limits low voltage (100-127VAC) to 550w per power supply. Thus, configurations requiring more
power are not redundant for low voltage installations, e.g., configurations with more than two processors.
8. 1U = 1.75in (44.45mm).
9. The Rack Extension Kits (P/N 36L9703 or 36L9702) add eight inches to the rear of a 9306-900, 910 or 9306-200 for cable
management and are recommended for systems greater than 24 inches in depth.
10. Optional rack power cords: P/N 94G6667 - 14ft NEMA 5-15P; P/N 94G7448 - 14ft IEC 320-C14.
11. Additional power cords are not required. This power supply option shares use of line cords provided with the base system.
Should be ordered in pairs to maintain redundancy.
12. Option includes two 560w hot-swap power supplies and a power backplane.
General rack placement rules and other information:
- Locate heaviest components at the bottom of the rack (i.e., UPS, then servers or storage, etc.).
- Do not extend more than one component on side rails at a time.
- Maximum of three UPSs (including no more than two APC 5000 UPSs) per rack.
- Utilize sidewall compartments for mounting PDUs and console switches prior to using EIA space.
- When mounting components in a rack, consider user and service requirements.
- When selecting length of power, console and storage cables, consider extension of cable management arms and overall
cable routing.
- BTUs = Watts x 3.41.
Содержание 6219 - IntelliStation M - Pro
Страница 179: ...Updated 02 Dec 02 141B...
Страница 243: ...BladeCenter HS20 this page intentionally blank this page intentionally blank Updated 02 Dec 02 191B...
Страница 273: ...IBM Rack Cabinets and Options this page intentionally blank this page intentionally blank Updated 02 Dec 02 217B...
Страница 282: ...226 Refer to the cable labeling key in the Cable Options table appearing later in this section...
Страница 283: ...227...