Chapter 2 EC Gateway Unit
2.5 Field Network General Specifications
2-22
ME0394-1A
2.5.7 PROFINET IO
Cable/connector specifications: Ethernet ANSI/TIA/EIA-568-B Category 5 or higher, shielded
8P8C modular plug (RJ45)
* It is to be prepared by the customer.
LED display
Name
Panel
notation
Display
color
Status
Description
STATUS 0
MS
Green
Light ON Normal communication
Blinking
(1 time) Network being diagnosed
Blinking
(2 times) Engineering tool is identifying the node
Orange
Light ON Exception error generated
(hardware failure)
Blinking
(1 time)
Settings and actual network
configuration differ
Blinking
(2 times) IP address not set
Blinking
(3 times) Station name not set
Blinking
(4 times) Internal error generated
Green/orange Light OFF Initializing
STATUS 1
NS
Green
Light ON Online status
(normal communication: RUN)
Blinking Online status (STOP)
Green/orange Light OFF No connection