Chapter 5 Operation
5.4 Gateway Parameter Configuration Tool
5-27
ME0394-1A
5.4.3 Explanation of Features in Special Parameter Setting
[GW parameters]
• Internal communication retry count : In AUTO, this is used to set the number of
communication retries with the connected axis.
[GW parameters 3]
• Delay time of driver reclosing :
Latency (interval) when supplying power to each unit of the
EC connection unit one by one should be set.
It is used for the purpose of reducing inrush current by
shifting the timing of power supplied to each axis.
The initial value for the latency is 5ms for each unit.