Chapter 5 Operation
5.2
Address Configuration
ME0394-1A
5-10
(3) Pressing / Pressing Start Point / Pressing Force
●
Pressing
Selection can be made from “Positioning Operation” and “Pressing Operation”.
When there is a check mark at “Pressing”, it should perform the pressing operation.
●
Pressing Start Point [mm] *Displayed only in pressing operation
It is the position to start the pressing operation. Input values from the home position.
Registration is available in 0.01mm unit
●
Pressing Force [% or N] *Displayed only in pressing operation
It is the current limit value at the pressing operation. Set in a value from 20 to 70% (Note).
Touch [Switch Unit] and input in N unit is also available.
Note: The input range available for the pressing current limit value should differ depending
on the models.
Refer to an instruction manual of each ELECYLINDER for detail.
Caution
●
The pressing force displayed in N unit is a reference.
Refer to an instruction manual of each ELECYLINDER or a catalog for detail.
●
When the pressing speed is set lower than the pressing speed of each model, the
pressing force could get unstable.
It could cause the performance not work properly.
Содержание Rec
Страница 2: ......
Страница 25: ...Actuator Coordinate System ME0394 1A Intro 17 4 Rotary type 330 degree rotation specification 0 330 ...
Страница 133: ...Parameter 6 1 Parameter list 6 1 6 2 Parameter Details 6 2 R E C Chapter 6 ...
Страница 155: ...Revision history ME0394 1A Post 1 Revision history Revision date Revised content 2020 02 First Edition ...
Страница 156: ......
Страница 157: ......
Страница 158: ......