Chapter 5 Operation
5.3 I/O Signals
ME0394-1A
5-22
The basic time chart is as follows.
Caution
●
The pressing speed should differ depending on the models.
Refer to an instruction manual of each ELECYLINDER or a catalog for detail.
●
The workpiece remains pressed after the pressing is completed.
If the workpiece moves or pushes back, it may be pressed even further.
●
Hitting a workpiece during the approaching operation will cause "Alarm Group A:
Overload Alarm".
ST signal
PE signal
ELECYLINDER
movement
PE signal ON
→ ST signal OFF
Pressing
operation
Approach operation
Not ON
at failure to contact
Pressing complete