Chapter 5 Operation
5.2 Address Configuration
5-7
ME0394-1A
I/O signal list
Signal type
Bit
Symbol
name
Content
PLC
out
put
Control
signal
15-0
-
Not available.
PLC
input
Status
signal
b15
*ALMH Turns ON if an error occurs that requires the gateway to be restarted.
(Likely due to a mistaken parameter setting. Confirm as needed.)
b14
-
Not available.
b13
MOD
Turns ON if MANU is selected with the unit front operation mode setting
switch, and turns OFF when AUTO is selected.
b12
ESTP It turns on with the STOP input from a teaching pendant. Once it turns
on, all the connected axes get into stop status.
b11-b8
-
Not available.
b7
ALMC
1 to 128
Outputs alarm codes caused by the gateway.
[For details, refer to "7.2 EC Gateway Unit Alarm Causes and
Countermeasures"]
b6
b5
b4
b3
b2
b1
b0