Chapter 5 Operation
5.2 Address Configuration
5-13
ME0394-1A
[I/O Signal List]
EC Connection Unit
(ON = corresponding bit is "1", OFF = corresponding bit is "0")
Signal type
Bit
Signal name
Content
Details
PLC
input
Status signal
(4th Axis)
b15
E3RD
Operation Ready
[On: Operation ready (servo on)]
Page
5-16
b14
*ALM
Alarm (break contact)
[ON
:
No alarm
、
OFF
:
Alarm generated]
Page
5-16
b13
LS1/PE1
Driving Forward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the forward end. It turns
on when pressing operation completes.]
Page
5-15 to 16
b12
LS0/PE0
Driving Backward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the backward end. It
turns on when pressing operation
completes.]
Page
5-15 to 16
Status signal
(3th Axis)
b11
E2RD
Operation Ready
[On: Operation ready (servo on)]
Page
5-16
b10
*ALM
Alarm (break contact)
[ON
:
No alarm
、
OFF
:
Alarm generated]
Page
5-16
b9
LS1/PE1
Driving Forward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the forward end. It turns
on when pressing operation completes.]
Page
5-15 to
16
b8
LS0/PE0
Driving Backward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the backward end. It
turns on when pressing operation
completes.]
Page
5-15 to 16
Status signal
(2nd Axis)
b7
E1RD
Operation Ready
[On: Operation ready (servo on)]
Page
5-16
b6
*ALM
Alarm (break contact)
[ON
:
No alarm
、
OFF
:
Alarm generated]
Page
5-16
b5
LS1/PE1
Driving Forward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the forward end. It turns
on when pressing operation completes.]
Page
5-15 to 16
b4
LS0/PE0
Driving Backward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the backward end. It
turns on when pressing operation
completes.]
Page
5-15 to 16
Status signal
(1st Axis)
b3
E0RD
Operation Ready
[On: Operation ready (servo on)]
Page
5-16
b2
*ALM
Alarm (break contact)
[ON
:
No alarm
、
OFF
:
Alarm generated]
Page
5-16
b1
LS1/PE1
Driving Forward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the forward end. It turns
on when pressing operation completes.]
Page
5-15 to 16
b0
LS0/PE0
Driving Backward Complete / Pressing
Complete
[It turns on when an actuator gets in the
detection range of the backward end. It
turns on when pressing operation
completes.]
Page
5-15 to 16
Содержание Rec
Страница 2: ......
Страница 25: ...Actuator Coordinate System ME0394 1A Intro 17 4 Rotary type 330 degree rotation specification 0 330 ...
Страница 133: ...Parameter 6 1 Parameter list 6 1 6 2 Parameter Details 6 2 R E C Chapter 6 ...
Страница 155: ...Revision history ME0394 1A Post 1 Revision history Revision date Revised content 2020 02 First Edition ...
Страница 156: ......
Страница 157: ......
Страница 158: ......