Chapter 1 System Configuration and Specifications
1.5
Specifications
ME0394-1A
1-5
1.5 Specifications
1.5.1 General specifications
The specifications regarding installation conditions are listed below.
Item
Specifications
Ambient operating
temperature
0 to 55
℃
Ambient operating
humidity
85% RH or less, non-condensing
Ambient storage
temperature
-20 to 70
°
C
Operating atmosphere Avoid corrosive gas and in particular avoid excessive dust
Altitude
1,000m or less
Vibration resistance
Frequency: 10 to 57 Hz/Amplitude: 0.075mm,
Frequency: 57 to 150 Hz/Acceleration: 9.8m/s
2
XYZ directions Sweep time: 10 minutes Number of sweeps: 10 times
Shock resistance
Drop height: 800mm
1 corner, 3 edges, 6 faces
Overvoltage category
I
Electric shock
protection mechanism
Class III
Pollution degree
II
Degree of protection
IP20
Insulation withstanding
voltage
500V DC 10M
Ω
(between Power Supply Terminal and Frame Ground)
Cooling method
Natural air cooling