Chapter 3 EC Connection Unit
3.4 Part Names/Functions and External Dimensions
3-7
ME0394-1A
3.4.2 LED display
Panel notation Display
color
Status
Description
T RUN
Green
Light ON Normal internal bus communication
Blinking Waiting for initialization signal, initialization communication failed
Orange
Light ON Bus communication error generated
SYS
Green
Light ON Servo ON
Blinking Servo OFF
Red
Light ON Alarm triggered
STOP signal input OFF (Drive source cutoff triggered)
LS1/ALM
(
I
= 1st axes,
II = 2nd axes,
III = 3rd axes,
IV = 4th axes)
Green
Light ON Movement to Forward End Complete
Blinking Stop
Red
Light ON Alarm triggered
LS0
(
I
= 1st axes,
II = 2nd axes,
III = 3rd axes,
IV = 4th axes)
Green
Light ON Movement to Backward End Complete
Blinking Stop