Chapter 5 Operation
5.2
Address Configuration
ME0394-1A
5-12
[I/O Signal List]
EC Connection Unit
(ON = corresponding bit is "1", OFF = corresponding bit is "0")
Signal type
Bit
Signal name
Content
Details
PLC
out
put
Control signal
(4th Axis)
b15
-
Not available
-
b14
RES
Alarm Cancel
[Alarm cancelled with on]
Page
5-15
b13
ST1
Drive Forward
[Drives forward with on (drives forward
after home-return operation when home
return not complete), decelerate and stop
on the way with off]
Page
5-14
b12
ST0
Drive Backward
[Drives backward with on (drives
backward after home-return operation
when home return not complete),
decelerate and stop on the way with off]
Page
5-14
Control signal
(3th Axis)
b11
-
Not available
-
b10
RES
Alarm Cancel
[Alarm cancelled with on]
Page
5-15
b9
ST1
Drive Forward
[Drives forward with on (drives forward
after home-return operation when home
return not complete), decelerate and stop
on the way with off]
Page
5-14
b8
ST0
Drive Backward
[Drives backward with on (drives
backward after home-return operation
when home return not complete),
decelerate and stop on the way with off]
Page
5-14
Control signal
(2nd Axis)
b7
-
Not available
-
b6
RES
Alarm Cancel
[Alarm cancelled with on]
Page
5-15
b5
ST1
Drive Forward
[Drives forward with on (drives forward
after home-return operation when home
return not complete), decelerate and stop
on the way with off]
Page
5-14
b4
ST0
Drive Backward
[Drives backward with on (drives
backward after home-return operation
when home return not complete),
decelerate and stop on the way with off]
Page
5-14
Control signal
(1st Axis)
b3
-
Not available
-
b2
RES
Alarm Cancel
[Alarm cancelled with on]
Page
5-15
b1
ST1
Drive Forward
[Drives forward with on (drives forward
after home-return operation when home
return not complete), decelerate and stop
on the way with off]
Page
5-14
b0
ST0
Drive Backward
[Drives backward with on (drives
backward after home-return operation
when home return not complete),
decelerate and stop on the way with off]
Page
5-14
Содержание Rec
Страница 2: ......
Страница 25: ...Actuator Coordinate System ME0394 1A Intro 17 4 Rotary type 330 degree rotation specification 0 330 ...
Страница 133: ...Parameter 6 1 Parameter list 6 1 6 2 Parameter Details 6 2 R E C Chapter 6 ...
Страница 155: ...Revision history ME0394 1A Post 1 Revision history Revision date Revised content 2020 02 First Edition ...
Страница 156: ......
Страница 157: ......
Страница 158: ......