Chapter 1 System Configuration and Specifications
1.5
Specifications
1-14
ME0394-1A
[Installation and mounting]
Consider the size of the control panel, placement of the REC controller, cooling and the like
when designing and manufacturing so that the ambient temperature is 0 to 55°C.
Item
Specifications
Item
Specifications
Installation direction
Vertical mounting (exhaust side on top)
Ambient operating
temperatur
0 to 55°C
Installation method
DIN rail mounting
Installation conditions
See figure below
Ground
Class D grounding
[Operating temperature range]
The operating temperature of the gateway unit/ EC Connection Unit is within the range of 0 to
55°C.
Caution
●
Under conditions where the temperature is higher than 55°C, the unit cannot be used,
regardless of the operating duty.
●
When used under unsuitable conditions, the alarm code 0CA "Heating error" may be
generated, causing the actuator to stop.
REC
Ceiling
Ceiling
100mm or more
50m
m
o
r m
ore
100m
m
or
m
or
e