Chapter
7 T
roubleshooting
7.3 Causes and countermeasures for ELECYLINDER alarms
ME0394-1A
7-5
7.3 Causes and countermeasures for ELECYLINDER alarms
7.3.1 Alarm Group
The alarm groups and warnings occurred in ELECYLINDER are as show below.
For details and countermeasures, refer to the next section, "Troubleshooting by alarm groups".
Alarm
group
Content
Main content and typical countermeasures
A
Overload alarm
[Content]
[Countermeasure]
Moving parts stopped abnormally.
Make sure that there are no obstructions
or obstacles.
B
Motor
error alarm
[Content]
[Countermeasure]
Motor abnormality occurred.
Replace the motor or controller.
C
ELECYLINDER
control unit
error alarm
[Content]
[Countermeasure]
ELECYLINDER control unit abnormality
occurred.
Replace the ELECYLINDER control unit.
D
ELECYLINDER
control unit-encoder
abnormality
alarm
[Content]
[Countermeasure]
An abnormality occurred between the
ELECYLINDER control unit and encoder.
Turn the power off and then on again.
If the unit still does not recover,
replace the motor or ELECYLINDER
control unit.
E
Power supply
voltage/Power
supply capacity
error alarm
[Content]
[Countermeasure]
ELECYLINDER control unit abnormality
occurred.
Check the power supply voltage for any
abnormality.
Alarm
group
Content
Main content and typical countermeasures
Warning
Maintenance
warning
[Content]
[Countermeasure]
The "maintenance period" has come to
an end.
Perform maintenance for the unit.
Содержание Rec
Страница 2: ......
Страница 25: ...Actuator Coordinate System ME0394 1A Intro 17 4 Rotary type 330 degree rotation specification 0 330 ...
Страница 133: ...Parameter 6 1 Parameter list 6 1 6 2 Parameter Details 6 2 R E C Chapter 6 ...
Страница 155: ...Revision history ME0394 1A Post 1 Revision history Revision date Revised content 2020 02 First Edition ...
Страница 156: ......
Страница 157: ......
Страница 158: ......