![IAI IA-101-TT-USB Скачать руководство пользователя страница 95](http://html.mh-extra.com/html/iai/ia-101-tt-usb/ia-101-tt-usb_operation-manual_603934095.webp)
3. Menu W
indow
87
(10) Controller (C) [7] All Data Backup (X) ▪ Transfer to Controller/Divide File (L) (continued)
The following section explains about “Transfer to Controller” and “Divide File.”
▪ Transfer to Controller
On the Data Transfer/Division Selection Screen, click Transfer to
Controller. The File Setup Screen will appear.
Select Backup All Saved Data (all data including programs, positions, etc.)
and transfer to the controller. (If you are not selecting all data, click
to
select the data to be transferred. The selected data will be marked with
.)
(Note) The parameter can not be sent if the selected parameter in the
controller is the same as the axis pattern.
(Note) Data saved in the regular format can be transferred to the
X-SEL-P/Q, PX/QX controller with the gateway function
compatible with increased memory.
Program of No. 65 or later will display a screen to ask if the
position of No. 4001 or later should be erased. Clicking Yes will
clear all the programs of No. 65 or later and positions of No. 4001
or later. Clicking No will not clear them.
Fig. 3.22 Confirmation Screen
(Note) Data saved in the extended format can be transferred to the
controller incompatible with increased memory.
Programs of No. 65 or later and positions of No. 4001 or later
cannot be transferred.
Parameters not supported by the controller at the destination
cannot be transferred.
The following warning screen will be displayed. Click Yes to
transfer data.
Fig. 3.23 Confirmation Screen
[In the case of X-SEL-P/Q/PX/QX and R/S/RX/SX/RXD/SXD controllers with the gateway function]
The following confirmation screen will be displayed after the program, parameter, position and symbol are
transferred, written to FROM and restarted.
[When RC-axis position data in X-SEL is used]
Click Yes to transfer the RC-axis position data in X-SEL.
Fig. 3.24 Confirmation Screen (while RC-axis position data is being transferred)
Содержание IA-101-TT-USB
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 50: ...1 Before You Begin 42 1 4 Connection to Controller Fig 1 48 X SEL K J Type Controller ...
Страница 52: ...1 Before You Begin 44 Figure shows example of TT Fig 1 50 Table Top Actuator TT TTA ...
Страница 53: ...1 Before You Begin 45 Fig 1 51 X SEL KX JX Type Controller ...
Страница 62: ...1 Before You Begin 54 Fig 1 60 ASEL Type Controller USB Cable ...
Страница 63: ...1 Before You Begin 55 Fig 1 61 PSEL Type Controller USB Cable ...
Страница 189: ...9 Symbol Edit Window 181 ...
Страница 251: ...13 How to Reset an Absolute Encoder 243 Fig 13 38 Arm Length 120 Reference Position ...
Страница 386: ...16 Appendix 378 ...
Страница 391: ......