13. How to Reset an
Absolute Encoder
347
5) Click “Execution” button.
<For 4-Axis Type>
Fig. 13.249 Execution Window
<For 3-Axis Type>
Fig. 13.250 Execution Window
6) A Warning window shows up. Click “Yes”. Process to acquire the push stopper position will start.
Fig. 13.251 Warning Window
7) For the four-axis type, press Execute and proceed to “Removing”, and then take off the rotary axis
pressing absolute reset jig. At this time, make sure the work is conducted with the emergency stop
activated. Click on the “OK” button after the work is finished.
Fig. 13.252 Jig Removing Window
8) Once the push stopper position acquisition is complete, the Information window will appear. Click
“OK” button.
Fig. 13.253 Information Window