UPS5000-E-(350 kVA-800 kVA)
User Manual (50 kVA Power Modules)
2 Overview
Issue 05 (2018-01-08)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
12
No.
Item
Description
capacity
500K: The output capacity is 500 kVA.
600K: The output capacity is 600 kVA.
800K: The output capacity is 800 kVA.
5
Configurati
on type
SM: standard configuration
FM: full configuration
The UPS5000-E-400K-SM/FM uses 50 kVA power modules. It can expand up to 400 kVA and is
compatible downwards to 50 kVA. This document describes the 400 kVA UPS.
The UPS5000-E-500K-SM/FM uses 50 kVA power modules. It can expand up to 500 kVA and is
compatible downwards to 50 kVA. This document describes the 500 kVA UPS.
The UPS5000-E-600K-SM/FM uses 50 kVA power modules. It can expand up to 600 kVA and is
compatible downwards to 50 kVA. This document describes the 600 kVA UPS.
The UPS5000-E-800K-SM/FM uses 50 kVA power modules. It can expand up to 800 kVA and is
compatible downwards to 50 kVA. This document describes the 800 kVA UPS.
2.2 Working Principle
indicates an input mode.
indicates the energy flow direction.
2.2.1 Conceptual Diagram
The UPS5000 is an online product. It uses a modular design, which facilitates maintenance
and capacity expansion. The UPS5000 uses the digital signal processing (DSP) technology for
intelligent control. Its power module consists of a rectifier, inverter, and DC/DC converter.
The UPS5000 converts inputs into pure high-quality sine wave outputs by using the
high-frequency switching technology.