Table 4-6 Technical specifications
Specifications
Specifications
Memory (RAM)
1 GB
Flash
Physical space: 512 MB. To view the actual available space,
run display version.
MTBF
59.88
MTTR
2
Availability
> 0.99999
Service port
surge protection
Common mode: ±7 kV (The maximum voltage is ±10 kV,
and the device is not damaged.)
Power port surge
protection
Differential mode: ±6 kV; common mode: ±6 kV
Dimensions (H x
W x D)
● Basic dimensions (the depth excludes the protruding
parts of the front and rear panels): 43.6 mm x 442.0 mm
x 420.0 mm
● Maximum dimensions (the depth is the maximum
distance from the protruding port on the front panel to
the module handle on the rear panel): 43.6 mm x 442.0
mm x 444.2 mm
Weight
(including
packing
materials)
7.39 kg
Stack port
Any 10/100/1000BASE-T Ethernet electrical port or 10GE SFP
+ Ethernet optical port
RTC
Supported
RPS
Not supported
PoE
Supported
Rated voltage
range
● AC input: 100–240 V AC; 50/60 Hz
● High-voltage DC input: 240 V DC
Maximum
voltage range
● AC input: 90–290 V AC; 45–65 Hz
● High-voltage DC input: 190–290 V DC
Maximum power
consumption
(100% traffic,
full fan speed)
● Without PoE: 65 W
● Full PoE load: 847 W (PoE: 720 W)
iMaster NetEco
Device Installation and Commissioning Guide (Data
Center)
4 Connecting Monitoring Cables to Devices
Issue 02 (2021-05-12)
Copyright © Huawei Technologies Co., Ltd.
75