282 Alphabetical list of commands
1 Capacitor Pack Voltage-Ctlr A 8.22 OK
1 Capacitor Pack Voltage-Ctlr B 8.26 OK
1 Capacitor Cell 1 Voltage-Ctlr A 2.04 OK
1 Capacitor Cell 1 Voltage-Ctlr B 2.06 OK
1 Capacitor Cell 2 Voltage-Ctlr A 2.04 OK
1 Capacitor Cell 2 Voltage-Ctlr B 2.06 OK
1 Capacitor Cell 3 Voltage-Ctlr A 2.08 OK
1 Capacitor Cell 3 Voltage-Ctlr B 2.06 OK
1 Capacitor Cell 4 Voltage-Ctlr A 2.05 OK
1 Capacitor Cell 4 Voltage-Ctlr B 2.09 OK
1 Capacitor Charge-Ctlr A 99% OK
1 Capacitor Charge-Ctlr B 99% OK
1 Overall Unit Status Error Error
1 Temperature Loc: upper-IOM A 35 C OK
1 Temperature Loc: lower-IOM B 27 C OK
1 Temperature Loc: left-PSU 21 C OK
1 Temperature Loc: right-PSU 34 C OK
1 Voltage 12V Loc: upper-IOM A 11.92 OK
1 Voltage 5V Loc: upper-IOM A 5.10 OK
1 Voltage 12V Loc: lower-IOM B 11.98 OK
1 Voltage 5V Loc: lower-IOM B 5.10 OK
1 Voltage 12V Loc: left-PSU Error
1 Voltage 5V Loc: left-PSU Error
1 Voltage 3.3V Loc: left-PSU Error
1 Voltage 12V Loc: right-PSU 12.49 OK
1 Voltage 5V Loc: right-PSU 5.58 OK
1 Voltage 3.3V Loc: right-PSU 3.60 OK
1 Current 12V Loc: upper-IOM A 4.42 OK
1 Current 12V Loc: lower-IOM B 4.42 OK
1 Current 12V Loc: left-PSU Error
1 Current 5V Loc: left-PSU Error
1 Current 12V Loc: right-PSU 0.00 OK
1 Current 5V Loc: right-PSU 0.00 OK
---------------------------------------------------------
Encl Sensor Name Value Status
---------------------------------------------------------
2 Temperature Loc: upper-IOM A 36 C OK
2 Temperature Loc: lower-IOM B 35 C OK
2 Temperature Loc: left-PSU 21 C OK
2 Temperature Loc: right-PSU 20 C OK
---------------------------------------------------------
Success: Command completed successfully. (2012-01-19 16:17:11)
Basetypes
•
sensors
•
status
Содержание P2000 G3
Страница 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Страница 14: ...14 About this guide ...
Страница 30: ...30 Categorical list of commands ...
Страница 96: ...96 Alphabetical list of commands exit Description Log off and exit the CLI session Syntax exit ...
Страница 159: ...HP P2000 G3 MSA System CLI Reference Guide 159 See also set host parameters show iscsi parameters ...
Страница 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Страница 217: ...HP P2000 G3 MSA System CLI Reference Guide 217 Basetypes drives enclosure list status See also show vdisks ...
Страница 223: ...HP P2000 G3 MSA System CLI Reference Guide 223 Basetypes email parameters status See also set email parameters ...
Страница 230: ...230 Alphabetical list of commands See also clear events set snmp parameters show snmp parameters ...
Страница 288: ...288 Alphabetical list of commands Basetypes snapshots status See also show master volumes show snap pools ...
Страница 292: ...292 Alphabetical list of commands Basetypes system unhealthy component status See also set system ...
Страница 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Страница 338: ...338 Alphabetical list of commands Basetypes remote links See also show remote systems verify remote link ...
Страница 340: ...340 Alphabetical list of commands Basetypes remote links See also show remote systems verify links ...
Страница 424: ...424 XML API basetype properties PROPERTY name utility priority numeric type string 0 PROPERTY OBJECT ...
Страница 469: ...HP P2000 G3 MSA System CLI Reference Guide 469 PROPERTY name status type string OK PROPERTY OBJECT ...
Страница 494: ...494 XML API basetype properties PROPERTY name sample time numeric type string 1329397200 PROPERTY OBJECT ...
Страница 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Страница 510: ...510 XML API basetype properties PROPERTY name reserve type numeric type string 0 PROPERTY OBJECT ...
Страница 524: ...524 Glossary ...
Страница 532: ...532 Index ...