190 Alphabetical list of commands
set volume
Description
Changes a volume’s name and OpenVMS UID or identifying information.
Syntax
set volume
[access read-write|rw|read-only|ro]
[identifying-information
description
]
[name
new-name
]
[ovms-uid
ID
]
volume
Parameters
access read-write|rw|read-only|ro
Deprecated; to change mapping settings, use the
map volume
on page 102.
identifying-information
description
Optional. A description of the volume to help a host-side user identify it. The value can have a
maximum of 127 bytes, using printable UTF-8 characters except left angle bracket, double quote, or
backslash. A value that contains a space must be enclosed in double quotes. If you specify this
parameter you cannot specify the
ovms-uid
parameter.
name
new-name
Optional. A new name for the volume. For volume syntax, see
Command syntax
on page 22.
ovms-uid ID
Optional. For a volume to be accessed by an OpenVMS host, assign a volume ID in the range
1–32767 to identify the volume to the host. If you specify this parameter you cannot specify the
identifying-information
parameter.
volume
Name or serial number of the volume to change. For volume syntax, see
Command syntax
on
page 22.
Example
Rename volume
V1
to
V2
:
# set volume name V2 V1
Success: Command completed successfully. - The specified volume name change(s)
were made. (2012-01-21 14:36:13)
Set identifying information for
V3
:
# set volume identifying-information "Project X data" V3
Success: Command completed successfully. - The specified volume name change(s)
were made. (2012-01-21 14:36:33)
See also
•
show host-maps
•
show volumes
•
show volume-maps
Содержание P2000 G3
Страница 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Страница 14: ...14 About this guide ...
Страница 30: ...30 Categorical list of commands ...
Страница 96: ...96 Alphabetical list of commands exit Description Log off and exit the CLI session Syntax exit ...
Страница 159: ...HP P2000 G3 MSA System CLI Reference Guide 159 See also set host parameters show iscsi parameters ...
Страница 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Страница 217: ...HP P2000 G3 MSA System CLI Reference Guide 217 Basetypes drives enclosure list status See also show vdisks ...
Страница 223: ...HP P2000 G3 MSA System CLI Reference Guide 223 Basetypes email parameters status See also set email parameters ...
Страница 230: ...230 Alphabetical list of commands See also clear events set snmp parameters show snmp parameters ...
Страница 288: ...288 Alphabetical list of commands Basetypes snapshots status See also show master volumes show snap pools ...
Страница 292: ...292 Alphabetical list of commands Basetypes system unhealthy component status See also set system ...
Страница 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Страница 338: ...338 Alphabetical list of commands Basetypes remote links See also show remote systems verify remote link ...
Страница 340: ...340 Alphabetical list of commands Basetypes remote links See also show remote systems verify links ...
Страница 424: ...424 XML API basetype properties PROPERTY name utility priority numeric type string 0 PROPERTY OBJECT ...
Страница 469: ...HP P2000 G3 MSA System CLI Reference Guide 469 PROPERTY name status type string OK PROPERTY OBJECT ...
Страница 494: ...494 XML API basetype properties PROPERTY name sample time numeric type string 1329397200 PROPERTY OBJECT ...
Страница 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Страница 510: ...510 XML API basetype properties PROPERTY name reserve type numeric type string 0 PROPERTY OBJECT ...
Страница 524: ...524 Glossary ...
Страница 532: ...532 Index ...