HP P2000 G3 MSA System CLI Reference Guide 135
partner-firmware-upgrade enabled|disabled|on|off
Optional. Sets whether component firmware versions are monitored and will be automatically
updated on the partner controller.
•
disabled
or
off
: Partner firmware upgrade is disabled.
•
enabled
or
on
: Partner firmware upgrade is enabled. This is the default.
partner-notify enabled|disabled|on|off
Optional. Sets whether to notify the partner controller that a trigger condition occurred. Enable this
option to have the partner also change to write-through mode for better data protection. Disable this
option to allow the partner continue using its current caching mode for better performance. The
default is
disabled
.
•
disabled
or
off
: Notification is disabled. This is the default.
•
enabled
or
on
: Notification is enabled.
power-supply-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when a power
supply fails.
•
disabled
or
off
: The power-supply failure trigger is disabled. This is the default.
•
enabled
or
on
: The power-supply failure trigger is enabled.
smart enabled|disabled|on|off|detect-only
Optional. Enables or disables SMART (Self-Monitoring Analysis and Reporting Technology)
monitoring for all disks in the storage system.
•
disabled
or
off
: Disables SMART for all disks in the system and for all disks added to the
system.
•
enabled
or
on
: Enables SMART for all disks in the system and for all disks added to the system.
This is the default.
•
detect-only
: Detects but does not change the SMART setting of each disk in the system, and
for each new disk added to the system.
super-cap-failure enabled|disabled|on|off
Optional. Sets whether the cache policy will change from write-back to write-through when the
super-capacitor that provides backup power for cache is not fully charged or fails.
•
disabled
or
off
: The super-capacitor failure trigger is disabled.
•
enabled
or
on
: The super-capacitor failure trigger is enabled. This is the default.
sync-cache-mode immediate|flush
Optional. Sets how the
SCSI SYNCHRONIZE CACHE
command is handled.
•
immediate
: Good status is returned immediately and cache content is unchanged. This option
is the default.
•
flush
: Good status is returned only after all write-back data for the specified volume is flushed
to disk.
temperature-exceeded enabled|disabled|on|off
Optional. Sets whether the system will shut down a controller when its temperature exceeds the
critical operating range.
•
disabled
or
off
: The over-temperature trigger is disabled. This is the default.
•
enabled
or
on
: The over-temperature trigger is enabled.
Содержание P2000 G3
Страница 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Страница 14: ...14 About this guide ...
Страница 30: ...30 Categorical list of commands ...
Страница 96: ...96 Alphabetical list of commands exit Description Log off and exit the CLI session Syntax exit ...
Страница 159: ...HP P2000 G3 MSA System CLI Reference Guide 159 See also set host parameters show iscsi parameters ...
Страница 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Страница 217: ...HP P2000 G3 MSA System CLI Reference Guide 217 Basetypes drives enclosure list status See also show vdisks ...
Страница 223: ...HP P2000 G3 MSA System CLI Reference Guide 223 Basetypes email parameters status See also set email parameters ...
Страница 230: ...230 Alphabetical list of commands See also clear events set snmp parameters show snmp parameters ...
Страница 288: ...288 Alphabetical list of commands Basetypes snapshots status See also show master volumes show snap pools ...
Страница 292: ...292 Alphabetical list of commands Basetypes system unhealthy component status See also set system ...
Страница 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Страница 338: ...338 Alphabetical list of commands Basetypes remote links See also show remote systems verify remote link ...
Страница 340: ...340 Alphabetical list of commands Basetypes remote links See also show remote systems verify links ...
Страница 424: ...424 XML API basetype properties PROPERTY name utility priority numeric type string 0 PROPERTY OBJECT ...
Страница 469: ...HP P2000 G3 MSA System CLI Reference Guide 469 PROPERTY name status type string OK PROPERTY OBJECT ...
Страница 494: ...494 XML API basetype properties PROPERTY name sample time numeric type string 1329397200 PROPERTY OBJECT ...
Страница 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Страница 510: ...510 XML API basetype properties PROPERTY name reserve type numeric type string 0 PROPERTY OBJECT ...
Страница 524: ...524 Glossary ...
Страница 532: ...532 Index ...