background image

232 Alphabetical list of commands

Disabled

Enabled

: PHY is enabled.

Disabled

: PHY is disabled.

Reason

Blank if 

Elem Status

 is 

OK

.

Error count interrupts

: PHY disabled because of error-count interrupts. 

Phy control

: PHY disabled by a SES control page as a result of action by a Storage 

Controller or user. 

Not ready

: PHY is enabled but not ready. Appears for SC-1 PHYs when the partner I/O 

module is not installed. Appears for Drive, SC-1, or Ingress PHYs when a connection problem 

exists such as a broken connector. 

Drive removed

: PHY disabled because drive slot is empty. 

Unused - disabled by default

: PHY is disabled by default because it is not used. 

Excessive Phy changes

: PHY is disabled because of excessive PHY change counts. 

Example

Show expander status for a single-enclosure system with an empty disk slot:

# show expander-status

Encl  Ctlr  Phy  Type    Status              Elem Status   Disabled

  Reason

-------------------------------------------------------------------------------

1    A     0    Drive   Enabled - Healthy   OK            Enabled

1    A     1    Drive   Enabled - Degraded  Non-critical  Enabled

  Not ready

  ...

1    A     23   Drive   Disabled            OK            Disabled

  Drive removed

1    A     0    SC-1    Enabled - Healthy   OK            Enabled

1    A     1    SC-1    Enabled - Healthy   OK            Enabled

1    A     0    SC-0    Enabled - Healthy   OK            Enabled

  ...

1    A     3    SC-0    Enabled - Healthy   OK            Enabled

1    A     0    Egress  Enabled - Healthy   OK            Enabled

  ...

1    A     3    Egress  Enabled - Healthy   OK            Enabled  
-------------------------------------------------------------------------------

Encl  Ctlr  Phy  Type    Status              Elem Status   Disabled

  Reason  
-------------------------------------------------------------------------------

1    B     0    Drive   Enabled - Healthy   OK            Enabled

1    B     1    Drive   Enabled - Degraded  Non-critical  Enabled

  Not ready

  ...

1    B     23   Drive   Disabled            OK            Disabled

  Drive removed

1    B     0    SC-1    Enabled - Healthy   OK            Enabled

1    B     1    SC-1    Enabled - Healthy   OK            Enabled

1    B     0    SC-0    Enabled - Healthy   OK            Enabled

  ...

1    B     0    Egress  Enabled - Healthy   OK            Enabled

  ...

1    B     3    Egress  Enabled - Healthy   OK            Enabled 
-------------------------------------------------------------------------------

Success: Command completed successfully. (2012-01-18 15:02:13)

Содержание P2000 G3

Страница 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...

Страница 2: ...under vendor s standard commercial license The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contai...

Страница 3: ...on 21 Command syntax 22 Command names and parameters 22 Disks 22 Vdisks 22 Volumes 22 Ports 22 Command completion editing and history 23 Viewing help 23 Size representations 23 Event log 24 2 Categorical list of commands 25 3 Alphabetical list of commands 31 abort replication 32 abort scrub 33 abort verify 34 abort volumecopy 35 add replication volume 36 clear cache 38 clear disk metadata 39 clear...

Страница 4: ... pool 97 expand vdisk 98 expand volume 100 export snapshot 101 map volume 102 meta 105 ping 106 reattach replication volume 107 release volume 109 remote 110 remove replication volume 111 replicate snapshot 112 replicate volume 113 rescan 114 reset all statistics 115 reset controller statistics 116 reset disk error statistics 117 reset disk statistics 118 reset host link 119 reset host port statis...

Страница 5: ...174 set schedule 176 set snap pool policy 177 set snap pool threshold 179 set snmp parameters 180 set spares 181 set system 183 set task 184 set user 186 set vdisk 189 set volume 190 show advanced settings 191 show auto write through trigger 195 show awt 196 show cache parameters 197 show certificate 200 show chap records 201 show cli parameters 202 show configuration 204 show controller date 205 ...

Страница 6: ...snap pools 284 show snapshots 286 show snmp parameters 289 show system 290 show system parameters 293 show task details 295 show tasks 300 show unwritable cache 306 show users 307 show vdisks 309 show vdisk statistics 312 show versions 316 show volumecopy status 316 show volume maps 317 show volume names 319 show volume reservations 320 show volumes 322 show volume statistics 325 shutdown 327 star...

Страница 7: ...port statistics 411 hosts 413 host view 414 host view mappings 415 inquiry 416 io modules 417 iscsi parameters 420 iscsi port 422 job parameters 423 license 425 log header table 428 master volumes 429 network parameters 430 ntp status 432 policy threshold 433 port 434 power supplies 437 redundancy 440 refresh counters 442 remote addresses 443 remote links 444 remote system 445 replicate volume tas...

Страница 8: ... 486 unhealthy component 487 unwritable cache 489 users 490 vdisk hist statistics 493 vdisk statistics 495 versions 497 virtual disk summary 499 virtual disks 500 volume copy status 506 volume copy tasks 507 volume names 508 volume reservations 509 volumes 511 volume statistics 515 volume view 517 volume view mappings 518 A Settings changed by restore defaults 519 Glossary 521 Index 525 ...

Страница 9: ...statistics properties 379 23 disk statistics properties 382 24 drive parameters properties 385 25 drive summary properties 387 26 drives properties 388 27 email parameters properties 393 28 enclosure components properties 395 29 enclosure fru properties 396 30 enclosure list properties 398 31 enclosures properties 399 32 enclosure sku properties 403 33 events properties 404 34 expander ports prope...

Страница 10: ...erties 472 75 snapshot with retention tasks properties 475 76 snap tasks properties 476 77 snmp parameters properties 477 78 status properties 478 79 system properties 479 80 system parameters table properties 481 81 tasks properties 484 82 time settings table properties 486 83 unhealthy component properties 487 84 unwritable cache properties 489 85 users properties 490 86 vdisk hist statistics pr...

Страница 11: ...nternet SCSI iSCSI and Ethernet protocols Related documentation In addition to this guide please refer to online help and the following documents for this product HP MSA System Racking Instructions HP P2000 G3 MSA Systems Installation Instructions HP P2000 G3 MSA System Cable Configuration Guide HP P2000 G3 FC MSA System User Guide HP P2000 G3 FC iSCSI MSA System User Guide HP P2000 G3 SAS MSA Sys...

Страница 12: ...cable error messages Operating system type and revision level Detailed specific questions For continuous quality improvement calls may be recorded or monitored Table 1 Document conventions Convention Element Medium blue text Figure 1 Cross reference links and e mail addresses Medium blue underlined text http www hp com Web site addresses Bold font Key names Text typed into a GUI element such as in...

Страница 13: ...e documentation updates as well as instant access to numerous other product resources After signing up you can quickly locate your products by selecting Business support and then Storage under Product Category HP web sites For other product information see the following HP web sites http www hp com http www hp com go storage http www hp com go p2000 manuals http www hp com support downloads http w...

Страница 14: ...14 About this guide ...

Страница 15: ... interface HCI XML API format which is the computer to computer interface CCI Console format enables users to interact with the CLI and obtain easily readable information This format automatically sizes fields according to content adjusts content to window resizes and displays some information in localized form These capabilities would present problems for a CCI in the form of scripts or other cli...

Страница 16: ...his is normal behavior Success Command completed successfully 2011 10 20 12 46 41 exit Using a script to access the CLI The following example shows how to construct a Perl script to communicate with the CLI via Telnet cLogin is called at the start of the script to log a user into the CLI The script uses the command line parameters specified as the IP address username and password After the user ha...

Страница 17: ... an expect type mechanism to scan output for prompts It is more efficient to use the HTTP interface to access the XML API The following example shows how to construct a Perl script to communicate with the XML API via HTTP use LWP UserAgent use Digest MD5 qw md5_hex use XML LibXML generate MD5 hash using default username password my md5_data manage_ manage my md5_hash md5_hex md5_data print md5_has...

Страница 18: ...sing the XML API The Management Controller provides access for monitoring and management via the Telnet and SSH protocols for command line interface semantics or via the HTTP and HTTPS protocols for XML API request response semantics You can use an XML parser such as XML Parser in Perl to process the XML output and store this information as objects The XML parser should use the Document Type Defin...

Страница 19: ... only one RESPONSE element per issued command OBJECT In general an OBJECT element describes a storage system component such as a disk or a volume An object has these attributes basetype This attribute allows output in brief mode to be correlated with metadata to reduce the overhead of each command as described in XML API optimization This is also a good field to use to detect the type of the objec...

Страница 20: ...ript each command should check the previous command s status before proceeding If the value of the status object s return code property is 0 the command succeeded any other value means that the command failed XML API examples The following example shows the same command formatted for use with the command line interface or for use with the HTTP interface and its XML API output Command line interfac...

Страница 21: ...e 1 PROPERTY PROPERTY name port key true A1 PROPERTY PROPERTY name port type type string FC PROPERTY PROPERTY name port type numeric type string 6 PROPERTY PROPERTY name media FC PROPERTY PROPERTY name target id target ID PROPERTY PROPERTY name status Disconnected PROPERTY PROPERTY name status numeric 6 PROPERTY PROPERTY name actual speed PROPERTY PROPERTY name actual speed numeric 255 PROPERTY PR...

Страница 22: ... enclosure ID and slot number Enclosure IDs increment from 1 Disk IDs increment from 1 in each enclosure You can specify A disk Example 1 4 A hyphenated range of disks Example 1 4 7 A comma separated list of individual disks ranges or both with no spaces Example 1 4 1 6 9 A RAID 10 or 50 vdisk with disks in sub vdisks separated by colons with no spaces RAID 50 example 1 1 3 1 4 6 1 7 1 10 11 Vdisk...

Страница 23: ...p To view help for a command and then return to the command prompt enter help command name To view the information shown in Command syntax above enter help syntax To view the information shown in this topic and in Command completion editing and history above enter help help Size representations Parameters such as names of users and volumes have a maximum length in bytes ASCII characters are 1 byte...

Страница 24: ...at may affect system stability but not data integrity Evaluate the problem and correct it if necessary Informational A configuration or state change occurred or a problem occurred that the system corrected No action is required For information about viewing events see the show events command Table 5 Size representations in base 2 and base 10 Base 2 Base 10 Unit Size in bytes Unit Size in bytes KiB...

Страница 25: ...d spares abort scrub abort verify clear disk metadata create vdisk delete global spare delete vdisks delete vdisk spare dequarantine expand vdisk rescan scrub disks scrub vdisk set expander fault isolation set led set spares set vdisk show disks show vdisks trust verify vdisk Volumes hosts and mapping create host create volume create volume set delete host delete volumes expand volume map volume r...

Страница 26: ...set priorities set snap pool policy set snap pool threshold show master volumes show priorities show snap pools show snapshots Volume copy abort volumecopy show volumecopy status volumecopy Scheduled tasks create schedule create task delete schedule delete task set schedule set task show schedule details show schedules show task details show tasks Event notification set email parameters set snmp p...

Страница 27: ... parameters show enclosures show enclosure status show expander status show fans show frus show host parameters show inquiry show iscsi parameters show job parameters show license show network parameters show ntp status show ports show power supplies show protocols show redundancy mode show sas link health show sensor status show shutdown status show system show system parameters show versions shu...

Страница 28: ...statistics show controller statistics show disk statistics show host port statistics show vdisk statistics show volume statistics Table 8 Replaced or removed commands Old command New command clear disk metadata clear disk metadata create host name create host create host wwn name create host create iscsi host create host delete host wwn name delete host delete iscsi host delete host expand master ...

Страница 29: ...atus show enclosures show frus show sensor status show host port interconnects None show host wwn names show hosts show iscsi hosts show hosts show lun maps show volume maps show output format show cli parameters show port wwn show ports Table 8 Replaced or removed commands continued Old command New command ...

Страница 30: ...30 Categorical list of commands ...

Страница 31: ...scription The command s purpose and notes about its usage Syntax The command s syntax Parameters Descriptions of the command s parameters Output Descriptions of fields shown in console format Example One or more examples of the command s usage in console format Basetypes References to descriptions of basetype properties shown in XML API format See also References to commands that are used with the...

Страница 32: ...tion set replication volume Parameters set replication set Optional Name or serial number of the replication set replication volume Name or serial number of the secondary volume If the name is not unique across replication sets specify the set parameter Example Abort replication of primary volume V1 to secondary volume rV1 abort replication rV1 Success Command completed successfully 2012 01 20 14 ...

Страница 33: ...mand syntax on page 22 disks disks Optional IDs of the disks to stop scrubbing For disk syntax see Command syntax on page 22 Example Abort scrubbing vdisk vd1 abort scrub vdisk vd1 Info Scrub was aborted on vdisk vd1 vd1 Success Command completed successfully 2012 01 20 15 42 08 Abort scrubbing disk 1 15 abort scrub disks 1 15 Info Abort scrubbing the disk at location 1 15 Success Command complete...

Страница 34: ...ks Parameters vdisk vdisks Names or serial numbers of the vdisks to stop verifying For vdisk syntax see Command syntax on page 22 Example Abort verifying vdisk vd1 abort verify vdisk vd1 Info The verify was aborted on vdisk vd1 vd1 2012 01 20 15 40 31 Success Command completed successfully 2012 01 20 15 40 31 See also show vdisks verify vdisk ...

Страница 35: ...ume Name or serial number of the source volume the destination volume or if a snapshot is being copied its associated master volume For volume syntax see Command syntax on page 22 Example Abort creating destination volume vd1_copy abort volumecopy v1_copy Success Command completed successfully vd1_copy The volume copy was aborted 2012 01 21 12 04 20 See also show volumecopy status show volumes vol...

Страница 36: ...only if the on collision parameter is set to oldest nowait Optional Adding a volume to a replication set can take the Storage Controller several minutes to complete This parameter allows that processing to continue in the background so the Management Controller can process other commands primary volume volume Name or serial number of the replication volume to be the primary volume for the replicat...

Страница 37: ...fo Started adding the secondary volume to the replication set MV2 Info Verifying that the secondary volume was added to the replication set This may take a couple of minutes MV2 Info The secondary volume was added to the replication set MV2 Success Command completed successfully 2012 01 21 17 37 40 Add secondary volume LosAngeles to a replication set that uses iSCSI links and whose primary volume ...

Страница 38: ...he is also called orphan data You can clear unwritable cache data for a specified volume or for all volumes Syntax clear cache volume volume Parameters volume volume Optional Name or serial number of the volume whose cache data should be cleared For volume syntax see Command syntax on page 22 If this parameter is omitted the command clears any unneeded orphaned data for volumes that are no longer ...

Страница 39: ...ausing the vdisk s health to become Degraded or Fault depending on the RAID level The disk s Fault UID LED is illuminated amber If spares are available and the health of the vdisk is Degraded the vdisk will use them to start reconstruction When reconstruction is complete you can clear the leftover disk s metadata Clearing the metadata will change the disk s health to OK and its How Used state to A...

Страница 40: ...l list of commands Try to clear metadata from a disk that is not leftover clear disk metadata 1 2 Error The specified disk is not a leftover disk 1 2 Metadata was not cleared for one or more disks 2012 01 18 10 32 59 ...

Страница 41: ... controller A B or both Syntax clear events a b both Parameters a b both Optional The controller event log to clear If this parameter is omitted both event logs are cleared Example Clear the event log for controller A clear events a Success Command completed successfully The event log was successfully cleared 2012 01 18 10 40 13 See also show events ...

Страница 42: ...how expander status command NOTE If a rescan is in progress the clear operation will fail with an error message saying that an EMP does exist Wait for the rescan to complete and then retry the clear operation Syntax clear expander status enclosure ID Parameters enclosure ID Optional The enclosure number Example Clear the expander status for the first enclosure clear expander status enclosure 1 Suc...

Страница 43: ...before converting the volume Syntax convert master to std master volume Parameters master volume Name or serial number of the master volume to convert For volume syntax see Command syntax on page 22 Example Convert a master volume having no snapshots to a standard volume convert master to std MV1 Success Command completed successfully MV1 The conversion of a master volume to a standard volume comp...

Страница 44: ...andard volume Parameters snap pool snap pool Name or serial number of the snap pool to associate with the new master volume For volume syntax see Command syntax on page 22 standard volume Name or serial number of the standard volume to convert For volume syntax see Command syntax on page 22 Example Convert standard volume V1 to a master volume and associate it with snap pool SP1 convert std to mas...

Страница 45: ...not exceed 100 characters and can include printable UTF 8 characters except space or semicolon An example is CO US ST CO O MyOrganization CN www mysite com This certificate is installed and the original certificate is archived restore Optional The archived original certificate is restored and the custom certificate is discarded The custom certificate may have been created with this CLI command or ...

Страница 46: ...d create certificate restore To make the certificate change take effect you must restart both Management Controllers by entering restart mc both Press Enter to acknowledge this message Success Command completed successfully Security certificate restored 2012 10 04 09 31 58 See also restart mc both show certificate ...

Страница 47: ... a z hyphen colon and period secret originator secret The secret that the recipient uses to authenticate the originator The secret is case sensitive and can include 12 16 bytes mutual name recipient name Optional for mutual CHAP only The recipient name typically in IQN format The name can have a maximum of 223 bytes including 0 9 lowercase a z hyphen colon and period To determine a storage system ...

Страница 48: ...ble quote left angle bracket or backslash and can have a maximum of 15 bytes A name that includes a space must be enclosed in double quotes profile standard openvms hp ux Optional standard The host allows LUN 0 to be assigned to a mapping This is the default openvms The host does not allow LUN 0 to be assigned to a mapping hp ux The host allows LUN 0 to be assigned to a mapping and uses Flat Space...

Страница 49: ...If base 10 is in use B bytes KB kilobytes MB megabytes or GB gigabytes If no unit is specified the unit is 512 byte blocks snap pool snap pool Optional Name or serial number of the snap pool to associate with the new master volume For volume syntax see Command syntax on page 22 If this parameter is omitted the system automatically creates a snap pool that is either 20 of the master volume s size o...

Страница 50: ...olume vdisk VD1 size 20GB snap pool SP1 lun 3 MV1 Info The volume was created MV1 Info The volume was mapped MV1 2012 01 18 12 30 22 Success Command completed successfully 2012 01 18 12 30 22 Create the 50 GB replication volume MV2 on vdisk VD1 and automatically create an associated 20 GB snap pool create master volume vdisk VD1 size 50GB prepare replication volume reserve 20GB MV2 Info The volume...

Страница 51: ... IP address in commands that need to interact with the remote system Syntax create remote system username username password password system Parameters username username Name of a user on the remote system This must be a manage level user to remotely configure or provision that system password password Password for that user system Network port IP address of the remote system Example Create a remot...

Страница 52: ...ation by specifying the snapshot parameter If you create a replication set without specifying a replication destination a partial set is created and you must use the add replication volume command to complete the set before you can perform replication IMPORTANT Before starting this procedure if you intend to use CHAP to authenticate iSCSI login requests between the local system and a remote system...

Страница 53: ...e number of 512 byte blocks for the size without appending a unit indicator For example in a P2000 G3 MSA System as a user with a base preference of 10 you create a 50 GB primary volume create volume vdisk vd 1 size 50GB PrimaryVol set cli parameters units MB precision 4 base 2 show volumes PrimaryVol Vdisk Name Size Serial Number vd 1 PrimaryVol 47683 6875MiB SN The number of 512 byte blocks woul...

Страница 54: ...ated on the secondary system will be the same size as the snap pool on the primary system remote volume volume Optional do not use with the remote vdisk parameter Name or serial number of a replication prepared volume to use as a secondary volume If the volume is on a remote system and the local and remote MCs can communicate you can specify a name or serial number otherwise you must specify a ser...

Страница 55: ...e of minutes rData Info The secondary volume was added to the replication set rData Info The primary volume is ready for replication Data Success Command completed successfully 2011 10 12 10 46 09 For two systems connected with FC links set up replication from local master volume Source to remote replication prepared volume Dest create replication set link type FC remote system System2 remote volu...

Страница 56: ...ical list of commands See also add replication volume delete replication set remove replication volume replicate snapshot show remote systems show replication images show replication sets show replication volumes ...

Страница 57: ...he retention count is 10 then the interval should be set to 10 minutes For a ReplicateVolume task the default and minimum interval is 30 minutes between hh mm AM PM and hh mm AM PM Constrains the time range during which the task is permitted to run Ensure that the start time is within the specified time range only any first second third fourth fifth last st nd rd th weekday weekendday Sunday Monda...

Страница 58: ...ccess Command completed successfully Sched2 The schedule was created 2012 01 20 15 46 16 Try to create Sched3 with a start time outside the between range create schedule schedule specification start 2012 01 14 4 15 PM between 12 00 AM and 12 00 PM task name Task3 Sched3 Error create schedule Sched3 The specified start time must be within the range specified with the between parameter 2012 01 20 15...

Страница 59: ...he unit is 512 byte blocks The supported minimum size is 5 GiB or 5 37 GB NOTE In rare cases a large amount of I O can cause a snap pool that is too small to fill quickly This can result in all snapshots being deleted due to the snap pool running out of space If you expect the snap pool to have a high rate of data change use the show snap pools command to view the snap pool s size If it is less th...

Страница 60: ...situation Syntax create snapshots volumes volumes master volumes master volumes snap names Parameters volumes volumes A comma separated list of up to 16 standard or master volumes to take snapshots of A standard volume is converted to a master volume before a snapshot is taken For volume syntax see Command syntax on page 22 master volumes master volumes Deprecated use the volumes parameter snap na...

Страница 61: ...d presented mapped to a host the snapshot must be unmounted unpresented unmapped before the reset is performed leaving it mounted presented mapped can cause data corruption You should create a scheduled job on the host to unmount unpresent unmap the snapshot prior to resetting it Syntax To create a task to take a snapshot create task type TakeSnapshot source volume volume snapshot prefix prefix re...

Страница 62: ...sk Snapshot names have the format prefix_s where starts at 001 retention count For a TakeSnapshot task this parameter specifies the number of snapshots created by this task to retain from 1 to the licensed limit When a new snapshot exceeds this limit the oldest snapshot with the same prefix is deleted For a ReplicateVolume task this parameter specifies the number of replication images created by t...

Страница 63: ...ate task Reset that resets snapshot VD1_V1_S0001 create task type ResetSnapshot snapshot volume VD1_V1_S0001 Reset Success Command completed successfully Reset The task was created 2012 01 19 15 46 21 Create task Copy that copies volume VD1_V1 to vdisk VD2 with name C_V0001 create task type VolumeCopy source volume VD1_V1 dest vdisk VD2 dest prefix C modified snapshot yes Copy Success Command comp...

Страница 64: ... whether to use a security authentication protocol Authentication uses the user password MD5 MD5 authentication This is the default SHA SHA Secure Hash Algorithm authentication none No authentication base 2 10 Optional Sets the base for entry and display of storage space sizes 2 Sizes are shown as powers of 2 using 1024 as a divisor for each magnitude 10 Sizes are shown as powers of 10 using 1000 ...

Страница 65: ... this specifies the encryption password For user password rules type help syntax privacy type DES AES none Optional For an SNMPv3 user this specifies whether to use a security encryption protocol This parameter requires the privacy password parameter and the authentication type parameter DES Data Encryption Standard AES Advanced Encryption Standard none No encryption This is the default storage si...

Страница 66: ...r name admin is reserved for internal use Example Create user John who will view system information using base 2 in SMU create user base 2 interfaces wbi level monitor John Enter new password Re enter new password Success Command completed successfully John The new user was created 2012 01 20 15 54 35 Create user MIB that can view the SNMP MIB using authentication and encryption create user interf...

Страница 67: ...disk To let the system automatically load balance vdisks between controllers use auto or omit this parameter In Single Controller mode this parameter is ignored the system automatically load balances vdisks in anticipation of the insertion of a second controller in the future spare disks Optional IDs of 1 4 dedicated spares to assign to a RAID 1 3 5 6 10 or 50 vdisk For disk syntax see Command syn...

Страница 68: ...in the first enclosure create vdisk level raid1 disks 1 1 1 3 VD1 Success Command completed successfully 2012 01 20 09 57 49 Create the RAID 50 vdisk VD2 having three RAID 5 sub vdisks each having three disks create vdisk level r50 disks 1 1 3 1 4 6 1 7 9 VD2 Success Command completed successfully 2011 10 03 11 12 54 Create the RAID 6 vdisk vdR6 using four disks create vdisk level r6 disks 2 3 4 2...

Страница 69: ... size using the current base as shown by the show cli parameters command The unit can be specified as follows If base 2 is in use B bytes KiB kibibytes MiB mebibytes or GiB gibibytes If base 10 is in use B bytes KB kilobytes MB megabytes or GB gigabytes If no unit is specified the unit is 512 byte blocks mapping ports LUN Deprecated use the ports and lun parameters access read write rw read only r...

Страница 70: ... to create a secondary volume instead of a regular master volume This parameter precludes use of the mapping lun and ports parameters because a secondary volume cannot be mapped ovms uid ID For a volume to be accessed by an OpenVMS host assign a volume ID in the range 1 32767 to identify the volume to the host name A name for the new volume The name is case sensitive cannot include a comma double ...

Страница 71: ...next volumes created will be vd1_v001 and vd1_v003 count The number of volumes to create from 1 to 128 Volumes are created up to the maximum number supported per vdisk size size B KB MB GB TB KiB MiB GiB TiB Sets the size for each volume using the current base as shown by the show cli parameters command The unit can be specified as follows If base 2 is in use B bytes KiB kibibytes MiB mebibytes or...

Страница 72: ...se name vd1_v in vdisk vd1 mapped starting with LUN 5 with read only access through port A1 and show the results create volume set count 10 size 20GB vdisk vd1 basename vd1_v baselun 5 access ro ports a1 Info The volume was created vd1_v000 Info The volume was created vd1_v009 Info The volume was mapped vd1_v000 Info The volume was mapped vd1_v009 Success Command completed successfully 2012 01 20 ...

Страница 73: ...HP P2000 G3 MSA System CLI Reference Guide 73 See also map volume set volume show vdisks show volume maps show volumes unmap volume ...

Страница 74: ...aster volumes Syntax delete all master volumes snap pool volume Parameters snap pool volume Name or serial number of the snap pool whose master volumes should be deleted For volume syntax see Command syntax on page 22 Example Delete all master volumes associated with snap pool SP1 delete all master volumes snap pool SP1 Success Command completed successfully SP1 All master volumes were deleted 201...

Страница 75: ...plication enabled systems only Type of snapshots that can be deleted If this parameter is omitted the default is all standard snapshots which means that the command will try to delete only standard snapshots and will not succeed if replication snapshots exist Example Delete all snapshots associated with master volume MV1 delete all snapshots volume MV1 Info This may take a few minutes if the syste...

Страница 76: ...in IQN format all Delete all CHAP records in the database Example Delete the CHAP record for a specific originator delete chap records name iqn 1991 05 com microsoft myhost domain Success Command completed successfully iqn 1991 05 com microsoft myhost domain The CHAP record was deleted 2012 01 20 12 40 22 Delete all CHAP records of which two exist delete chap records all Info Removed CHAP record 0...

Страница 77: ...eters disks disks IDs of the global spares to delete For disk syntax see Command syntax on page 22 Example Delete two global spares delete global spare disks 1 1 1 5 Info Global spare disk 1 1 was deleted 1 1 Info Global spare disk 1 5 was deleted 1 5 Success Command completed successfully 2012 01 20 11 32 56 See also delete vdisk spare set spares show disks ...

Страница 78: ...host host Parameters host The ID or nickname of the host Example Delete the manually created host named MyHost delete host MyHost Success Command completed successfully 2012 01 18 17 06 41 Delete the discovered host named Host1 delete host Host1 Success Command completed successfully 2011 10 10 17 06 51 Try to delete the mapped host whose ID is 100000062b0e5e15 delete host 100000062b0e5e15 Error T...

Страница 79: ...for the master volume before you can delete it Syntax delete master volume volume Parameters volume Name or serial number of the master volume to delete For volume syntax see Command syntax on page 22 Example Delete master volume MV1 delete master volume MV1 Success Command completed successfully MV1 The master volume was deleted 2012 01 21 12 13 00 See also delete all snapshots show master volume...

Страница 80: ...er appear in user interfaces record this information before deleting the remote system so that you can access it at a later time such as to delete old replication images or for disaster recovery Syntax delete remote system system Parameters system Name or network port IP address of the remote system Example Delete remote system System2 delete remote system System2 Success Command deleted successfu...

Страница 81: ...stem s license This command must be run on the primary system Syntax delete replication set ID Parameters ID Name or serial number of either the replication set or its primary volume Example Delete replication set RS1 delete replication set RS1 Info The replication set has been deleted RS1 Success Command completed successfully 2012 01 21 12 16 58 Delete the replication set with primary volume MV1...

Страница 82: ... can delete the schedule When a component is deleted its schedules and tasks are also deleted Syntax delete schedule schedule Parameters schedule The schedule to delete Example Delete schedule Sched1 delete schedule Sched1 Success Command completed successfully Sched1 The schedule was deleted 2012 01 21 17 05 15 See also show schedule details show schedules ...

Страница 83: ... before you can delete it Syntax delete snap pool snap pool Parameters snap pool Name or serial number of the snap pool to delete For volume syntax see Command syntax on page 22 Example Delete snap pool SP1 delete snap pool SP1 Success Command completed successfully SP1 The snap pool was deleted 2012 01 18 12 13 46 See also show master volumes show snap pools ...

Страница 84: ...ity snapshots You must specify this parameter or the force parameter but not both force Optional Overrides priority protection and forces the specified snapshot to be deleted You must specify this parameter or the delete priority parameter but not both snapshots Names or serial numbers of the snapshots to delete For volume syntax see Command syntax on page 22 Example Delete snapshot SS1 which is b...

Страница 85: ...ommand is not allowed for a replication snapshot Syntax delete snapshot write data snapshot Parameters snapshot Name or serial number of the snapshot to delete modified data from For volume syntax see Command syntax on page 22 Example Delete only modified data from snapshot SS1 delete snapshot write data SS1 Success Command completed successfully SS1 Snapshot write data was deleted 2012 01 21 09 5...

Страница 86: ...chedules that use the task Syntax delete task task Parameters task The task to delete Example Delete task Task1 delete task Task1 Success Command completed successfully Task1 The task was deleted 2012 01 21 17 05 46 See also delete schedule show schedule details show schedules show task details show tasks ...

Страница 87: ...cifying this parameter allows the command to proceed without user interaction name The user to delete Names are case sensitive Example Delete user jsmith delete user jsmith Are you sure you want to delete user jsmith yes Success Command completed successfully 2011 10 10 15 55 16 Delete user Kim and suppress the confirmation prompt delete user noprompt Kim Success Command completed successfully 201...

Страница 88: ...nse to the prompt that appears if a utility is running on the vdisk yes Stop the utility and allow the command to proceed no Cancel the command If this parameter is omitted you must manually reply to the prompt vdisks Names or serial numbers of the vdisks to delete For vdisk syntax see Command syntax on page 22 Example Delete vdisks VD1 and VD2 delete vdisks VD1 VD2 Info Vdisk VD1 was deleted VD1 ...

Страница 89: ...res to delete For disk syntax see Command syntax on page 22 vdisk Name or serial number of the vdisk to delete the spares from For disk syntax see Command syntax on page 22 Example Delete spare disk 1 5 from vdisk VD1 delete vdisk spare disks 1 5 VD1 Info Vdisk spare disk 1 5 was deleted 1 5 Success Command completed successfully 2011 10 12 11 11 29 See also delete global spare set spares show dis...

Страница 90: ... delete volumes volumes Parameters volumes Names or serial numbers of the volumes to delete For volume syntax see Command syntax on page 22 Example Delete volumes V1 and V2 delete volumes V1 V2 Info Volume V1 was deleted V1 2012 01 18 12 18 50 Info Volume V2 was deleted V2 2012 01 18 12 18 50 Success Command completed successfully 2012 01 18 12 18 50 See also show volumes ...

Страница 91: ...ause of an inaccessible disk event 172 is logged If quarantine occurs to prevent writing invalid data event 485 is logged Examples of when quarantine can occur are At system power up a vdisk has fewer disks online than at the previous power up This may happen because a disk is slow to spin up or because an enclosure is not powered up The vdisk will be automatically dequarantined if the inaccessibl...

Страница 92: ...anually dequarantine the vdisk If the inaccessible disks later come online they are marked as LEFTOVR leftover If event 172 was logged do not use the dequarantine command instead follow the event s recommended action text If event 485 was logged use the dequarantine command only as specified by the event s recommended action text to avoid data corruption or loss When a vdisk is dequarantined event...

Страница 93: ...quarantined remove it from quarantine and re check its status show vdisks Name Status VD1 QTDN RAID 6 quarantined with a down disk dequarantine vdisk VD1 Success Command completed successfully show vdisks Name Status VD1 FTDN RAID 6 fault tolerant with a down disk See also show vdisks trust ...

Страница 94: ...ndary volumes Detached volumes remain associated with their replication sets but are not updated with replication data or with replication control information When a volume is detached its status is shown as Detached NOTE It is recommended that the vdisk that you are moving contains only secondary volumes and their snap pools You are allowed to move other volumes along with secondary volumes and t...

Страница 95: ...HP P2000 G3 MSA System CLI Reference Guide 95 See also reattach replication volume show replication sets show replication volumes start vdisk stop vdisk ...

Страница 96: ...96 Alphabetical list of commands exit Description Log off and exit the CLI session Syntax exit ...

Страница 97: ...iB Specifies the size using the current base as shown by the show cli parameters command The unit can be specified as follows If base 2 is in use B bytes KiB kibibytes MiB mebibytes or GiB gibibytes If base 10 is in use B bytes KB kilobytes MB megabytes or GB gigabytes If no unit is specified the unit is 512 byte blocks size max Expands the volume to fill available space on the vdisk snap pool Nam...

Страница 98: ...ntax expand vdisk disks disks prompt yes no vdisk Parameters disks disks IDs of the disks to add For disk syntax for RAID levels other than RAID 10 and RAID 50 see Command syntax on page 22 For RAID 10 and RAID 50 you must use a comma not a colon to separate each mirror pair or sub vdisk prompt yes no Optional Specifies an automatic response to the confirmation prompt yes Allow the command to proc...

Страница 99: ...D 10 vdisk R10 to include two additional mirror pairs expand vdisk disks 2 4 2 8 2 9 10 R10 Expand RAID 50 vdisk R50 which has three 3 disk sub vdisks to include one additional 3 disk sub vdisk expand vdisk disks 2 1 2 2 5 R50 See also show disks show vdisks ...

Страница 100: ...B MiB GiB TiB volume To expand to the maximum size expand volume size max volume Parameters size size B KB MB GB TB KiB MiB GiB TiB Specifies the size using the current base as shown by the show cli parameters command The unit can be specified as follows If base 2 is in use B bytes KiB kibibytes MiB mebibytes or GiB gibibytes If base 10 is in use B bytes KB kilobytes MB megabytes or GB gigabytes I...

Страница 101: ...n a remote system or if the resulting snapshot would exceed license limits Syntax export snapshot name standard snapshot set replication set replication snapshot Parameters name standard snapshot A name for the resulting snapshot set replication set Optional Name or serial number of the replication set replication snapshot Name or serial number of the replication snapshot to export If the name is ...

Страница 102: ...n LUN ports ports host hosts volumes Parameters access read write rw read only ro no access Optional The access permission available to attached hosts read write rw read only ro or no access If the access parameter is specified as read write or read only either the mapping parameter or the lun parameter must be specified For an explicit mapping no access causes the volume to be masked from specifi...

Страница 103: ...Info Mapping succeeded Host 207000c0ff001122 was mapped for volume v2 with LUN 101 v2 2012 01 18 13 58 41 Info Mapping succeeded Host 207000c0ff001122 was mapped for volume v3 with LUN 102 v3 2012 01 18 13 58 41 Success Command completed successfully 2011 09 28 13 58 41 Mask volume v4 from Host1 and Host3 map volume v4 access no access host Host1 Host3 Info Mapping succeeded Host 207000c0ff001121 ...

Страница 104: ...001122 Host2 Standard not mapped all other hosts Standard Volume View Serial Number SN Name v2 Mapping Ports LUN Access Host Port Identifier Nickname Profile A1 B1 7 read write 207000c0ff001121 Host1 Standard A1 B1 7 read write 207000c0ff001122 Host2 Standard not mapped all other hosts Standard Success Command completed successfully 2012 01 18 14 44 01 See also show host maps show hosts show volum...

Страница 105: ...tics hosts host view host view mappings inquiry iscsi parameters iscsi port job parameters license log header table managed logs master volumes network parameters ntp status policy threshold port power supplies redundancy refresh counters remote addresses remote links remote system replicate volume tasks replication image replication image params replication set replication volume replication volu...

Страница 106: ...ameters host address The remote host s IP address in dotted decimal form count Optional The number of packets to send The default is 4 packets Use a small count because the command cannot be interrupted Example Send two packets to the remote computer at 10 134 50 6 ping 10 134 50 6 2 Info Pinging 10 134 50 6 with 2 packets Success Command completed successfully The remote computer responded with 2...

Страница 107: ...ls and says it is unable to get the primary volume s link type the vdisk that contains the secondary volume may not have completed its startup activities Wait approximately one minute for these activities to complete then retry the operation If this message continues to occur check the event log to better understand the condition and for an indication of how to correct it NOTE If the secondary sys...

Страница 108: ...108 Alphabetical list of commands See also detach replication volume show replication sets show replication volumes start vdisk stop vdisk ...

Страница 109: ... and return them to a clean state CAUTION Releasing reservations for volumes may allow unintended access to those volumes by other hosts which may result in data corruption Before issuing this command quiesce all hosts that have visibility to the volumes whose reservations will be released Syntax release volume all volumes Parameters all volumes Specifies all volumes or the names or serial numbers...

Страница 110: ...e system command Parameters system Name or network port IP address of the remote system command Any CLI command that is valid for the remote user s access level Example Run the show vdisks command on remote system System2 remote System2 show vdisks Name Size Free Own Pref RAID Disks Spr Chk Status Jobs Job Serial Number Drive Spin Down Spin Down Delay VD1 587 1GB 116 7GB B B RAID50 6 0 64k FTOL VR...

Страница 111: ...an process other commands primary volume volume Optional use only if the replication set has a primary volume conflict Name or serial number of the primary volume set replication set Optional Name or serial number of the replication set replication volume Name or serial number of the secondary volume to remove If the name is not unique within the replication set the volume that is not the primary ...

Страница 112: ...sk use the replicate volume command Syntax replicate snapshot name replication snapshot set replication set external snapshot Parameters name replication snapshot Optional A name for the resulting replication snapshot set replication set Optional Name or serial number of the replication set external snapshot Name or serial number of the external snapshot to use as the data source If the name is no...

Страница 113: ...x replicate volume set replication set snapshot replication snapshot preserve snapshot external snapshot volume Parameters set replication set Optional Name or serial number of the replication set snapshot replication snapshot Name for the new replication snapshot preserve snapshot external snapshot Optional Name of the external snapshot to use as the source for this replication This preserves the...

Страница 114: ...sumes normal operation It can take up to two minutes for the enclosure IDs to be corrected A manual rescan may be needed after system power up to display enclosures in the proper order Whenever you replace a drive chassis or controller chassis perform a manual rescan to force fresh discovery of all drive enclosures connected to the controller enclosure A manual rescan is not needed after inserting...

Страница 115: ...ation prompt that will appear if the historical parameter is specified yes Allow the command to proceed no Cancel the command If the historical parameter is specified and the prompt parameter is omitted you must manually reply to the prompt If the historical parameter is omitted the prompt parameter has no effect There is no confirmation prompt for live statistics Example Reset all live statistics...

Страница 116: ...h Parameters a b both Optional Specifies whether to reset statistics for controller A B or both If this parameter is omitted statistics are reset for both controllers Example Reset statistics for both controllers reset controller statistics Success Command completed successfully 2012 01 21 11 35 06 See also reset all statistics reset disk error statistics reset disk statistics reset host port stat...

Страница 117: ...d not categorized as media errors Number of block reassignments Number of bad blocks found To reset other disk statistics use the reset disk statistics command Syntax reset disk error statistics disks Parameters disks Optional IDs of the disks to reset statistics for For disk syntax see Command syntax on page 22 If this parameter is omitted statistics are reset for all disks Example Reset error st...

Страница 118: ...reset these use the reset disk error statistics command Syntax reset disk statistics Example Reset statistics for all disks reset disk statistics Success Command completed successfully 2012 01 21 11 35 52 See also reset all statistics reset controller statistics reset disk error statistics reset host port statistics reset vdisk statistics reset volume statistics show disk statistics ...

Страница 119: ...INIT COMRESET sequence and might reset other ports Syntax reset host link ports ports Parameters port ports A controller host port ID a comma separated list of IDs a hyphenated range of IDs or a combination of these A port ID is a controller ID and port number and is not case sensitive Do not mix controller IDs in a range Example Reset the host link on port A1 reset host link ports A1 Success Comm...

Страница 120: ...tics for For port syntax see Command syntax on page 22 If this parameter is omitted statistics are reset for all controller host ports Example Reset statistics for all controller host ports reset host port statistics Success Command completed successfully 2012 01 21 11 36 59 See also reset all statistics reset controller statistics reset disk error statistics reset disk statistics reset vdisk stat...

Страница 121: ...y to the prompt noprompt Optional in console format required for XML API format Suppresses the confirmation prompt which requires a yes or no response Specifying this parameter allows the command to proceed without user interaction Example Reset the SMI S configuration on controller A which you are logged in to reset smis configuration a WARNING The configuration of the SMIS service will be reset ...

Страница 122: ...l be reset to default settings Any hosts registered via SMIS will need to be registered again Are you sure yes Info SMIS service configuration has been reset for local controller 2013 01 10 16 56 41 Info SMIS service configuration has been reset for partner controller 2013 01 10 16 56 41 Success Command completed successfully 2013 01 10 16 56 41 See also restore defaults ...

Страница 123: ...uing this command is lost Syntax reset snapshot prompt yes no volume Parameters prompt yes no Optional Specifies an automatic response to the prompt to unmount unpresent unmap the snapshot before proceeding yes Allow the command to proceed no Cancel the command If this parameter is omitted you must reply to the prompt volume Name or serial number of the snapshot to reset For volume syntax see Comm...

Страница 124: ...r For vdisk syntax see Command syntax on page 22 If this parameter is omitted statistics are reset for all vdisks Example Reset statistics for vdisks VD1 and MyVdisk reset vdisk statistics VD1 MyVdisk Success Command completed successfully 2012 01 21 11 37 44 See also reset all statistics reset controller statistics reset disk error statistics reset disk statistics reset host port statistics reset...

Страница 125: ...statistics for For volume syntax see Command syntax on page 22 If this parameter is omitted statistics are reset for all volumes Example Reset statistics for volume vd1_v001 reset volume statistics vd1_v001 Success Command completed successfully 2012 01 21 11 38 05 See also reset all statistics reset controller statistics reset disk error statistics reset disk statistics reset host port statistics...

Страница 126: ...l controller system disk statistics may be reduced but will not be reset to zero because disk statistics are summed between the two controllers For more information see help for commands that show statistics Syntax restart sc mc a b both noprompt Parameters sc mc The controller to restart sc Storage Controller mc Management Controller a b both Optional The controller module containing the controll...

Страница 127: ...start both Storage Controllers restart sc both Restarting both controllers can cause a temporary loss of data availability Do you want to continue yes Success Command completed successfully Both SCs were restarted 2012 01 21 13 09 52 See also shutdown ...

Страница 128: ...no Parameters noprompt Optional in console format required for XML API format Suppresses the confirmation prompt which requires a yes or no response Specifying this parameter allows the command to proceed without user interaction prompt yes no Optional Specifies an automatic response to the confirmation prompt yes Allow the command to proceed no Cancel the command If this parameter is omitted you ...

Страница 129: ... replication volume Parameters set replication set Optional Name or serial number of the replication set replication volume Name or serial number of the secondary volume If the name is not unique across replication sets specify the set parameter Example Resume replication of primary volume V1 to secondary volume rV1 resume replication rV1 Success Command completed successfully 2012 01 20 14 51 14 ...

Страница 130: ...ack to For volume syntax see Command syntax on page 22 modifiedsnapshot yes no Optional Specifies whether to include or exclude modified write data from the snapshot in the rollback yes Include modified snapshot no Exclude modified snapshot data If this parameter is omitted modified snapshot data is excluded prompt yes no Optional Specifies an automatic response to the prompt to unmount unpresent ...

Страница 131: ...DRSC job use the show disks command When a disk scrub operation starts event 208 is logged When a disk scrub operation ends event 209 is logged and specifies whether errors were found and whether user action is required Syntax scrub disks disks Parameters disks IDs of the disks to scrub For vdisk syntax see Command syntax on page 22 Example Start scrubbing disks 1 1 and 1 3 scrub disks 1 1 1 3 Inf...

Страница 132: ...ub enabled with the set job parameters command You can use a vdisk while it is being scrubbed To check the progress of a vdisk scrub VRSC job use the show vdisks command When a vdisk scrub operation starts event 206 is logged When a vdisk scrub operation ends event 207 is logged and specifies whether errors were found and whether user action is required Syntax scrub vdisk vdisks Parameters vdisks ...

Страница 133: ...meters auto write back enabled disabled on off Optional Sets whether the cache mode will change from write through to write back when the trigger condition is cleared disabled or off Auto write back is disabled enabled or on Auto write back is enabled This is the default background disk scrub enabled disabled on off Optional Sets whether disks that are not in vdisks are automatically checked for d...

Страница 134: ...fault is 5 seconds fan failure enabled disabled on off Optional Sets whether the cache policy will change from write back to write through when a fan fails disabled or off The fan failure trigger is disabled This is the default enabled or on The fan failure trigger is enabled host cache control enabled disabled on off Optional Sets whether hosts are allowed to use the SCSI MODE SELECT command to c...

Страница 135: ...Analysis and Reporting Technology monitoring for all disks in the storage system disabled or off Disables SMART for all disks in the system and for all disks added to the system enabled or on Enables SMART for all disks in the system and for all disks added to the system This is the default detect only Detects but does not change the SMART setting of each disk in the system and for each new disk a...

Страница 136: ...disks and global spares is enabled spin down delay delay Optional Sets the period of inactivity after which available disks and global spares will spin down The default is 15 minutes Setting the delay to 1 360 minutes will enable spin down setting the delay to 0 will disable spin down single controller Optional for use by a service technician only For a system that had two controller modules but n...

Страница 137: ...che is not fully charged or fails disabled or off The super capacitor failure trigger is disabled enabled or on The super capacitor failure trigger is enabled This is the default compact flash failure enabled disabled on off Optional Sets whether the cache policy will change from write back to write through when CompactFlash memory is not detected during POST Power On Self Test fails during POST o...

Страница 138: ...is is the default enabled or on Notification is enabled auto write back enabled disabled on off Optional Sets whether the cache mode will change from write through to write back when the trigger condition is cleared disabled or off Auto write back is disabled enabled or on Auto write back is enabled This is the default Example Enable the controller failure trigger and disable the partner notificat...

Страница 139: ...Use this setting only when operating in an environment with low or no fault tolerance You can configure the write policy to automatically change from write back to write through when certain environmental events occur such as a fan failure For details see help for the set auto write through trigger command optimization standard Optional Sets the cache optimization mode standard Optimizes cache for...

Страница 140: ...x see Command syntax on page 22 Example Set the cache policy and cache optimization mode for volume V1 set cache parameters optimization standard read ahead size maximum V1 Success Command completed successfully Cache parameters were changed 2012 01 21 11 52 03 See also show cache parameters show volumes ...

Страница 141: ...a z hyphen colon and period To determine a storage system s IQN use the show ports command to view an iSCSI port Target ID value This parameter and mutual secret must be set together mutual secret recipient secret Optional for mutual CHAP only The secret that the originator uses to authenticate the recipient The secret is case sensitive can include 12 16 bytes and must differ from the originator s...

Страница 142: ... each magnitude This is the default Operating systems usually show volume size in base 2 Disk drives usually show size in base 10 Memory RAM and ROM size is always shown in base 2 console api api embed Optional Sets the output format console Supports interactive use of the CLI by displaying command output in easily readable format This format automatically sizes fields according to content adjusts...

Страница 143: ...30 minutes units auto MB GB TB Optional Sets the unit for display of storage space sizes auto Sizes are shown in units determined by the system This is the default MB Sizes are shown in megabytes GB Sizes are shown in gigabytes TB Sizes are shown in terabytes Based on the precision setting if a size is too small to meaningfully display in the selected unit the system uses a smaller unit for that s...

Страница 144: ...timestamp set controller date timestamp timestamp timezone hh mm To configure use of NTP set controller date ntp enabled disabled on off ntpaddress IP address timezone hh mm Parameters jan feb mar apr may jun jul aug sep oct nov dec The month day The day number 1 31 hh mm ss The hour 0 23 the minutes 0 59 and the seconds 0 59 year The year as a four digit number ntp enabled disabled on off Enables...

Страница 145: ... 1320273050 timezone 6 Success Command completed successfully Date Time successfully set 2011 11 02 16 30 53 Set the system to use NTP with an offset for the Mountain Time zone set controller date ntp enabled ntpaddress 69 10 36 3 timezone 7 Success Command completed successfully Date Time successfully set 2011 11 02 12 15 22 Set the system to use NTP with an offset for the Bangalore India time zo...

Страница 146: ...ID debug messages Enabled by default hb Not used host Host interface debug messages Enabled by default init Not used ioa I O interface driver debug messages standard Enabled by default iob I O interface driver debug messages resource counts Disabled by default ioc I O interface driver debug messages upper layer verbose Disabled by default iod I O interface driver debug messages lower layer verbose...

Страница 147: ...d disabled on off spin down delay delay Parameters smart enabled disabled on off detect only Optional Sets whether SMART is enabled or disabled for disks disabled or off Disables SMART for all disks in the system and for all disks added to the system enabled or on Enables SMART for all disks in the system and for all disks added to the system This is the default detect only Detects but does not ch...

Страница 148: ...LogCollector MyDomain com include logs enabled disabled on off Optional When the managed logs feature is enabled this option activates the push mode automatically attaching system log files to managed logs email notifications that are sent to the log collection system This option is disabled by default notification level crit error warn info none The minimum severity for which the system should se...

Страница 149: ...omain com JSmith domain2 com logcollector mydomain com Info Set Email Address 1 to sysadmin mydomain com sysadmin mydomain com Info Set Email Address 2 to JSmith domain2 com sysadmin mydomain com Info Set Email Address 3 to Info Set Email Address 4 to logcollector mydomain com logcollector mydomain com Info Set Email Server Name to 10 1 1 10 10 1 1 10 Info Set Email Domain Name to mydomain com myd...

Страница 150: ...he name can include a maximum of 20 bytes using printable UTF 8 characters except double quote left angle bracket comma or backslash A value that contains a space must be enclosed in double quotes location location The location of the enclosure The name can include a maximum of 20 bytes using characters except double quote left angle bracket comma or backslash A value that contains a space must be...

Страница 151: ...tion is disabled and a PHY failure occurs Syntax set expander fault isolation encl enclosure ID controller a b both enabled disabled on off Parameters encl enclosure ID The enclosure ID of the enclosure containing the PHY controller a b both The I O module containing the Expander Controller whose setting you want to change A B or both enabled disabled on off Whether to enable or disable PHY fault ...

Страница 152: ...er enabled disabled on off Whether to enable or disable the specified PHY Example Disable the first egress PHY in controller A and check the resulting status set expander phy encl 1 controller a type egress phy 0 disabled Success Command completed successfully Disabled PHY 0 on controller a in enclosure 1 PHY type egress 2012 01 21 12 07 36 show expander status Encl Ctlr Phy Type Status Elem Statu...

Страница 153: ...HP P2000 G3 MSA System CLI Reference Guide 153 See also set expander fault isolation show enclosures show expander status ...

Страница 154: ...kname Optional Changes the host s nickname to the specified name The name is case sensitive cannot include a comma double quote left angle bracket or backslash and can have a maximum of 15 bytes A name that includes a space must be enclosed in double quotes If this parameter is omitted for a manually created host the host will be removed Example Initially set the nickname for a discovered host set...

Страница 155: ...o loop Fibre Channel Arbitrated Loop public or private point to point Fibre Channel point to point auto Loop preferred otherwise point to point based on the detected connection type This is the default You must also specify the ports parameter fibre loop id values Optional For FC specifies comma separated loop ID values to request for host ports when controllers arbitrate during a LIP Use this opt...

Страница 156: ...pt yes no expert Optional Specifies an automatic response to the confirmation prompt yes Allow the command to proceed no Cancel the command expert Allow the command to proceed If this parameter is omitted you must manually reply to the prompt speed 2g 4g 8g auto Optional For FC sets a forced link speed in Gbit sec or lets the speed be auto negotiated auto Because a speed mismatch prevents communic...

Страница 157: ...lly The host parameters were changed successfully 2012 01 21 15 46 14 On a system with iSCSI ports for port A3 change the IP address set host parameters ip 10 134 50 6 port a3 iscsi ip version ipv4 WARNING This change will take effect immediately Changes may affect access to data Are you sure yes Success Command completed successfully The host parameters were changed successfully 2012 01 21 15 46 ...

Страница 158: ...mapping Disabled by default isns ip iSNS IP Specifies the IP address of an iSNS server The default address is all zeroes isns alt ip iSNS IP Optional Specifies the IP address of an alternate iSNS server which can be on a different subnet The default address is all zeroes iscsi ip version ipv4 ipv6 Optional Specifies whether to use IP version 4 IPv4 or 6 IPv6 for addressing controller iSCSI ports i...

Страница 159: ...HP P2000 G3 MSA System CLI Reference Guide 159 See also set host parameters show iscsi parameters ...

Страница 160: ...undancy utilities such as vdisk verify and reconstruct run with respect to I O operations competing for the system s processors This does not affect vdisk background scrub which always runs at background priority high Utilities have higher priority than host I O Use when your highest priority is to return the system to a fully fault tolerant state This can cause heavy I O to be slower than normal ...

Страница 161: ...an enclosure LED set led enclosure ID enable disable on off Parameters disk ID The disk to locate For disk syntax see Command syntax on page 22 enclosure ID The enclosure to locate enable disable on off Specifies to set or unset the LED Example Identify disk 5 in the first enclosure set led disk 1 5 on Success Command completed successfully Enabling identification LED for disk 1 5 2012 01 21 12 23...

Страница 162: ...o switch a controller from DHCP addressing to static addressing you must set the IP address netmask and gateway values You can also set link speed auto negotiation and duplex mode parameters to enable Ethernet switches to communicate with the storage system These settings will persist if the Ethernet cable is disconnected and reconnected but will revert to default values if the controller is remov...

Страница 163: ...n Because the controller will choose the proper duplex mode for the negotiated speed you cannot specify the duplex mode parameter disabled or off Disables auto negotiation If you disable auto negotiation and don t specify the link speed and duplex mode parameters the controller will use the current settings of the network port If this command is specified and the auto negotiation parameter is omit...

Страница 164: ...essfully Request to set network parameters has been initiated 2012 10 18 15 38 10 For the controller you are accessing for which auto negotiation is disabled set the network port to use a maximum link speed of 10 Mb s and half duplex mode set network parameters link speed 10mbps duplex mode half WARNING You are attempting to change the Ethernet settings for this Management Controller which will af...

Страница 165: ...TP server timezone hh mm The system s time zone as an offset in hours 1 to 12 1 to 13 and minutes 0 59 from Coordinated Universal Time UTC For example the Pacific Time Zone offset is 8 during Pacific Standard Time or 7 during Pacific Daylight Time Example Set the system to use NTP with an offset for the Mountain Time zone set ntp parameters ntp enabled ntpaddress 69 10 36 3 timezone 7 Success Comm...

Страница 166: ...r an SNMPv3 user whose authentication type parameter is set to use authentication this specifies the authentication password For user password rules type help syntax user Optional The user name to set the password for If this parameter is omitted this command affects the logged in user s password Example Change the password for the default user manage set password manage Enter new password Re ente...

Страница 167: ...Optional Retention priority for a snapshot that is being replicated to a secondary volume This snapshot is required in order to resume the replication The attribute is temporary for the duration of the replication process The default is 0xc000 49152 common sync point Optional Retention priority for the latest snapshot that is copy complete on all secondary volumes It identifies a common point in t...

Страница 168: ...t which can include any printable UTF 8 characters except left angle bracket backslash and double quote and can have a maximum of 16 bytes A prompt that includes a space must be enclosed in double quotes Example Change the prompt from to CLI and start entering another command set prompt CLI Success Command completed successfully 2012 08 14 14 47 23 CLI show ...

Страница 169: ...erface This is enabled by default smis enabled disabled on off Optional Enables or disables the secure Storage Management Initiative Specification interface SMI S interface This option allows SMI S clients to communicate with each controller s embedded SMI S provider via HTTPS port 5989 HTTPS port 5989 and HTTP port 5988 cannot be enabled at the same time so enabling this option will disable port ...

Страница 170: ...sword to access the remote system The value is displayed in clear text username username Optional New user name to access the remote system system Name or network port IP address of the remote system Example Change the password that is stored to access a remote system set remote system password Abc_123 System2 Info The password was set System2 2012 01 21 14 45 22 Success Command completed successf...

Страница 171: ...lume can take the Storage Controller several minutes to complete This parameter allows that processing to continue in the background so the Management Controller can process other commands primary volume replication volume Name or serial number of the replication volume to designate as the new primary volume for the replication set If the name is not unique you must specify the serial number set r...

Страница 172: ...onflict rData Online Remote Data Conflict On System1 as already done on System2 set rData to be the primary volume set replication primary volume volume Data primary volume rData Info Started setting the primary volume of the replication set RS Info Setting the primary volume of the replication set This may take a couple of minutes RS Info Successfully set primary volume rData Info The primary vol...

Страница 173: ...HP P2000 G3 MSA System CLI Reference Guide 173 See also show replication sets show replication volumes show snapshots unmap volume ...

Страница 174: ... error occurs If another error occurs and the difference in time between when the error occurs and the initial retry time is greater than the max retry time value the replication will be suspended In order to prevent a replication set from suspending when multiple independent discontinuous errors occur during a single replication set max retry time for the secondary volume either to 0 retry foreve...

Страница 175: ...1 10 134 2 2 set replication set Optional Name or serial number of the replication set replication volume Name or serial number of the replication volume If the name is not unique within the replication set the local volume is assumed If the name is not unique across replication sets specify the set parameter Example Set a new remote address and error policy for replication volume MV2 in replicati...

Страница 176: ...ot task that will run under heavy I O conditions or on more than three volumes the retention count and the schedule interval should be set to similar values for example if the retention count is 10 then the interval should be set to 10 minutes For a ReplicateVolume task the minimum interval is 30 minutes between hh mm AM PM and hh mm AM PM Constrains the time range during which the task is permitt...

Страница 177: ...the snap pool by the snap pool s autoexpansionsize value below If the snap pool is successfully expanded the system will log Informational event 444 If the snap pool cannot be expanded because there is not enough available space in its vdisk the system will log Warning event 444 and will automatically delete the oldest snapshot that is not a current sync point Each time the snap pool s error thres...

Страница 178: ...P1 to automatically expand by 10 GB when its error threshold is reached set snap pool policy error autoexpand autoexpansionsize 10GB SP1 Success Command completed successfully 2012 01 21 12 32 28 See also set priorities set snap pool threshold show snap pools ...

Страница 179: ... When this threshold is reached an event is generated to alert the administrator and the associated snap pool policy is triggered Syntax set snap pool threshold warning error snap pool Parameters warning The percent of snap pool space used that triggers the warning threshold policy This value must be less than the error threshold value The default is 75 error The percent of snap pool space used th...

Страница 180: ...nation host that will receive traps Three trap hosts can be set del trap host address Optional Deletes a trap destination host trap host list trap host list Optional Replaces the current list read community string Optional Sets a community string for read only access This value is also included in traps that are sent The value is case sensitive can include any character except left angle bracket s...

Страница 181: ...pares or none to delete all global spares if no vdisk is specified or all dedicated spares for a specified vdisk For disk syntax see Command syntax on page 22 vdisk vdisk Optional Name or serial number of the vdisk to assign spares to For vdisk syntax see Command syntax on page 22 If this parameter is omitted the disks will be global spares Example Designate disk 1 2 as a global spare set spares d...

Страница 182: ...182 Alphabetical list of commands See also delete global spare delete vdisk spare set advanced settings show disks show vdisks ...

Страница 183: ...ed in system debug logs for reference by service personnel When using the WBI the system name appears in the browser title bar or tab Syntax set system name value contact value location value info value Parameters name value A name to identify the system contact value The name of the person who administers the system location value The location of the system info value A brief description of what ...

Страница 184: ...new image exceeds this limit the oldest image with the same prefix is deleted This parameter applies to the primary volume only for the secondary volume images will accumulate until either the secondary vdisk s space limit is reached or the maximum number of images is reached after which the oldest image will be deleted as new images are created dest vdisk vdisk Optional Name or serial number of t...

Страница 185: ...ed Copy set task dest vdisk VD3 dest prefix VD1v1 modified snapshot no Copy Success Command completed successfully Copy The task was modified 2012 01 21 12 37 52 Change parameters for a ReplicateVolume type task named Replicate set task snapshot prefix VD1v2 replication mode last snapshot Replicate Success Command completed successfully Replicate The task was modified 2012 01 21 12 37 57 See also ...

Страница 186: ...rature scale celsius c fahrenheit f timeout trap host IP address type novice standard advanced diagnostic units auto MB GB TB name Parameters authentication type MD5 SHA none Optional For an SNMPv3 user this specifies whether to use a security authentication protocol This parameter requires the password parameter and for the snmptarget interface the trap host parameter MD5 MD5 authentication This ...

Страница 187: ...XML API format Sets a new password for the user For an SNMPv3 user whose authentication type parameter is set to use authentication this specifies the authentication password For user password rules type help syntax precision Optional Sets the number of decimal places 1 10 for display of storage space sizes The default is 1 privacy password encryption password Optional For an SNMPv3 user whose pri...

Страница 188: ... precision setting if a size is too small to meaningfully display in the selected unit the system uses a smaller unit for that size For example if units is set to TB precision is set to 1 and base is set to 10 the size 0 1 1709 TB is instead shown as 1 17 1 GB name Specifies the user account to change Names are case sensitive Example Change the temperature scale and accessible interfaces for user ...

Страница 189: ...activity after which the vdisk s disks and dedicated spares automatically spin down from 1 360 minutes Setting the delay to 1 360 minutes will enable spin down setting the delay to 0 will disable spin down NOTE Drive spin down affects disk operations as follows Spun down disks are not polled for SMART events Operations requiring access to disks may be delayed while the disks are spinning back up v...

Страница 190: ...parameter you cannot specify the ovms uid parameter name new name Optional A new name for the volume For volume syntax see Command syntax on page 22 ovms uid ID Optional For a volume to be accessed by an OpenVMS host assign a volume ID in the range 1 32767 to identify the volume to the host If you specify this parameter you cannot specify the identifying information parameter volume Name or serial...

Страница 191: ...than host I O This can cause heavy I O to be slower than normal This is the default Medium Utility performance is balanced with host I O performance Low Utilities run at a slower rate with minimal effect on host I O SMART Shows whether SMART Self Monitoring Analysis and Reporting Technology is enabled or disabled for disks Detect Only Each disk in the system retains its individual SMART setting as...

Страница 192: ... to write through when the super capacitor that provides backup power for cache is not fully charged or fails Disabled The super capacitor failure trigger is disabled Enabled The super capacitor failure trigger is enabled This is the default CompactFlash Failure Shows whether the cache policy will change from write back to write through when CompactFlash memory is not detected during POST Power On...

Страница 193: ...in down for available disks and global spares is disabled This is the default Enabled Drive spin down for available disks and global spares is enabled Drive Spin Down Non Vdisk Delay Shows the period of inactivity in minutes after which available disks and global spares will spin down from 1 360 minutes The default is 15 minutes The value 0 means spin down is disabled Disk Background Scrub Shows w...

Страница 194: ... Immediate Independent Cache Performance Mode Disabled Missing LUN Response Not Ready Controller Failure Disabled Supercap Failure Enabled CompactFlash Failure Enabled Power Supply Failure Disabled Fan Failure Disabled Temperature Exceeded Disabled Partner Notify Disabled Auto Write Back Enabled Drive Spin Down Non Vdisk Enable Enabled Drive Spin Down Non Vdisk Delay 30 Disk Background Scrub Disab...

Страница 195: ...abled Enabled The CompactFlash failure trigger is enabled This is the default Power Supply Failure Shows whether the cache policy will change from write back to write through when a power supply fails Disabled The power supply failure trigger is disabled This is the default Enabled The power supply failure trigger is enabled Fan Failure Shows whether the cache policy will change from write back to...

Страница 196: ...o Write Through Triggers Controller Failure Disabled Supercap Failure Enabled CompactFlash Failure Enabled Power Supply Failure Disabled Fan Failure Disabled Temperature Exceeded Disabled Partner Notify Disabled Auto Write Back Enabled Success Command completed successfully 2012 01 18 14 30 31 Basetypes auto write through trigger status See also set auto write through trigger ...

Страница 197: ... system has lost redundancy Down Both controllers are not operational Write Back Status Shows the current system wide cache policy as determined by auto write through AWT logic This value is not settable by users If an AWT trigger condition such as a CompactFlash failure is met the cache policy for all volumes changes to write through overriding the volume specific settings When the problem is cor...

Страница 198: ...andom order such as transaction based and database update applications This is the default Read Ahead Size If a volume is specified its read ahead cache setting Disabled Read ahead caching is disabled Default One chunk for the first access in a sequential read and one stripe for all subsequent accesses Maximum Maximum read ahead size calculated by the controller 64 KB 128 KB 256 KB 512 KB 1 MB 2 M...

Страница 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...

Страница 200: ...r supplied A custom or alternate certificate has been installed Time Created Date and time in the format year month day hour minutes seconds when the custom certificate was created Example Show certificate status for the system show certificate Certificate Status Certificate Status Customer supplied Time Created 2012 09 27 10 41 03 Success Command completed successfully 2012 09 27 11 15 09 Basetyp...

Страница 201: ...he recipient uses to authenticate the originator Mutual CHAP Name For mutual CHAP the recipient name Mutual CHAP Secret For mutual CHAP the secret that the originator uses to authenticate the recipient Example Show the CHAP record for a specific host initiator show chap records name iqn 1991 05 com microsoft myhost domain CHAP Record s Initiator Name iqn 1991 05 com microsoft myhost domain Initiat...

Страница 202: ...put shows all attributes of object properties This is the default Base Base for entry and display of storage space sizes 2 Sizes are shown as powers of 2 using 1024 as a divisor for each magnitude 10 Sizes are shown as powers of 10 using 1000 as a divisor for each magnitude This is the default Operating systems usually show volume size in base 2 Disk drives usually show size in base 10 Memory RAM ...

Страница 203: ...ees Celsius This is the default Example Show current CLI settings show cli parameters CLI Parameters Timeout 1800 Output Format Console Brief Mode Disabled Base 10 Pager Enabled Locale English Precision 1 Units Auto Temperature Scale Celsius Success Command completed successfully 2012 01 18 14 32 33 Basetypes cli parameters status See also set cli parameters ...

Страница 204: ...are version information from versions with the details option Host and expansion port information from show ports Disk information from show disks Disk information by enclosure from show disks with the encl option Vdisk information from show vdisks Enclosure status information from show enclosures Field replaceable unit FRU information from show frus Basetypes system controllers versions port driv...

Страница 205: ...onds Time Zone Offset The system s time zone as an offset in hours and minutes from Coordinated Universal Time UTC This is shown only if NTP is enabled Example Show the date and time on a system that is using NTP show controller date Controller Date 2012 01 18 14 57 04 Time Zone Offset 6 00 Success Command completed successfully 2012 01 18 14 57 04 Basetypes time settings table status See also set...

Страница 206: ... Address Controller network port MAC address WWNN Storage system World Wide Node Name WWNN IP Address Controller network port IP address IP Subnet Mask Controller network port IP subnet mask IP Gateway Controller network port gateway IP address Disks Number of disks in the storage system Vdisks Number of vdisks in the storage system Cache Memory Size MB Controller module cache memory size MB Host ...

Страница 207: ...ntroller in the enclosure Top The controller is in the top slot Bottom The controller is in the bottom slot Phy Isolation Shows whether the automatic disabling of SAS expander PHYs having high error counts is enabled or disabled for this controller Enabled PHY fault isolation is enabled This is the default Disabled PHY fault isolation is disabled Controller Redundancy Mode Shows the system s opera...

Страница 208: ...17 Vdisks 2 Cache Memory Size MB 1024 Host Ports 4 Disk Channels 2 Disk Bus Type SAS Status Operational Failed Over to This Controller No Fail Over Reason Not applicable Health OK Health Reason Health Recommendation Position Top Phy Isolation Enabled Controller Redundancy Mode Active Active ULP Controller Redundancy Status Redundant Controllers Controller ID B Success Command completed successfull...

Страница 209: ... has not been requested or reset since a controller restart Number of Reads Number of read operations since these statistics were last reset or since the controller was restarted Number of Writes Number of write operations since these statistics were last reset or since the controller was restarted Data Read Amount of data read since these statistics were last reset or since the controller was res...

Страница 210: ...210 Alphabetical list of commands See also reset all statistics reset controller statistics show disk statistics show host port statistics show vdisk statistics show volume statistics ...

Страница 211: ...nal debug messages Enabled by default rcm Removable component manager debug messages Disabled by default raid RAID debug messages Enabled by default cache Cache debug messages Enabled by default emp Enclosure Management Processor debug messages Enabled by default capi Internal Configuration API debug messages Enabled by default mui Internal service interface debug messages Enabled by default bkcfg...

Страница 212: ... an I O operation is aborted and possibly retried Overall Timeout Total time in seconds before an I O operation is failed regardless of the Attempt Timeout and Number of Retries settings Drive Spin Down Non Vdisk Enable Shows whether available disks and global spares will spin down after a period of inactivity shown by the Drive Spin Down Non Vdisk Delay field Disabled Drive spin down for availabl...

Страница 213: ...bout For disk syntax see Command syntax on page 22 free Optional Shows information about all disks that are available all Optional Shows information about all installed disks vdisk vdisk Optional Shows information for disks in the specified vdisk For vdisk syntax see Command syntax on page 22 perf Optional Shows performance statistics from the latest historical sample for each disk Statistics show...

Страница 214: ...rate in Gbit second A footnote indicates that it is normal behavior for the rate to vary Some 6 Gbps disks might not consistently support a 6 Gbps transfer rate If this happens the P2000 controller automatically adjusts transfers to those disks to 3 Gbps increasing reliability and reducing error messages with little impact on system performance This rate adjustment persists until the controller is...

Страница 215: ...system is having communication problems with the disk LED processor For disk and midplane types where this processor also controls power to the disk power on failure will result in Error status Error The disk is present but is not detected by the expander Unknown Initial status when the disk is first detected or powered on Not Present The disk slot indicates that no disk is present Encl Enclosure ...

Страница 216: ...3 0 OK 2 1 SN vendor rev GLOBAL SP SATA S 120 0GB 1 5 A OK 2 2 SN vendor rev VDISK VRFY SATA S 120 0GB 1 5 A OK Info Rates may vary This is normal behavior 2012 01 18 08 10 01 Success Command completed successfully 2012 01 18 08 10 01 Show information for all disks show disks encl Status Encl Slot Vendor Model Serial Number Size Up 1 1 vendor model SN 146 8GB Not Present 1 2 N A N A N A N A Succes...

Страница 217: ...HP P2000 G3 MSA System CLI Reference Guide 217 Basetypes drives enclosure list status See also show vdisks ...

Страница 218: ...storical statistics If this parameter is omitted live statistics will be shown time range date time range Optional Specifies the date time range of historical statistics to show in the format start yyyy mm dd hh mm AM PM end yyyy mm dd hh mm AM PM If the start date time is specified but no end date time is specified the current date time will be used as the end date time The system will return the...

Страница 219: ... number Total I Os Total number of read and write operations since the last sampling time Number of Reads Shown by the all parameter Number of read operations since the last sampling time Number of Writes Shown by the all parameter Number of write operations since the last sampling time Data Transferred Total amount of data read and written since the last sampling time Data Read Shown by the all p...

Страница 220: ...l parameter Average data size of write operations since the last sampling time Number of Disk Errors Shown by the all parameter Total number of disk errors detected since the last sampling time Error types include number of SMART events number of timeouts accessing the disk number of times the disk did not respond number of attempts by the storage system to spin up the disk media errors generated ...

Страница 221: ...ble ID Serial Number disk_1 5 SN Total I Os Number of Reads Number of Writes Data Transferred Data Read Data Written Total IOPS Read IOPS Write IOPS Total Bps Read Bps Write Bps Queue Depth I O Resp Time Read Resp Time Write Resp Time Average I O Size Average Read I O Size Average Write I O Size Number of Disk Errors Sample Time 121174 60588 60586 5800 5MB 2900 3MB 2900 1MB 134 67 67 6445 0KB 3222...

Страница 222: ...ations Log Destination Shows the email address for the log collection system used by the managed logs feature Email Server The IP address of the SMTP mail server to use for the email messages Email Domain The domain name that with the sender name forms the from address for remote notification Email Sender The sender name that with the domain name forms the from address for remote notification Incl...

Страница 223: ...HP P2000 G3 MSA System CLI Reference Guide 223 Basetypes email parameters status See also set email parameters ...

Страница 224: ...pe 2U24 6Gv2 Midplane for 2U reduced depth 24 disk enclosure with 6 Gbps maximum data rate to disks 2U24 6G Midplane for 2U 24 disk enclosure with 6 Gbps maximum data rate to disks 2U24 3G Midplane for 2U 24 disk enclosure with 3 Gbps maximum data rate to disks 2U12 6Gv2 Midplane for 2U reduced depth 12 disk enclosure with 6 Gbps maximum data rate to disks 2U12 6G Midplane for 2U 12 disk enclosure...

Страница 225: ...ame Location Rack Pos Vendor Model EMP A CH ID Rev EMP B CH ID Rev Midplane Type Health Health Reason Health Recommendation 1 WWN Controller Lab 0 4 vendor model 01 031 1115 00 031 1115 2U24 3G OK Success Command completed successfully 2012 01 18 15 01 05 Basetypes enclosures status See also set enclosure show sensor status ...

Страница 226: ...er WWPN World wide port name of the SES device reporting the enclosure status Status Overall status of the enclosure Absent The enclosure is not present Error The enclosure has a fault OK The enclosure is operating normally Not Available Status is not available Enclosure Component Status fields Type Component type FAN Cooling fan unit PSU Power supply unit Temp Temperature sensor Voltage Voltage s...

Страница 227: ... voltage For a voltage sensor the voltage No data Example Show enclosure status show enclosure status Chassis Vendor Product ID CPLD EMP A CH ID Rev EMP B CH ID Rev WWPN Status SN vendor product 21 00 031 1115 01 031 1115 WWPN OK Type Status FRU P N FRU S N Add l Data FAN 01 OK PN SN PSU 01 OK PN SN Temp 01 OK PN SN temp 37 C Voltage 01 OK PN SN voltage 11 86 Disk 01 OK PN SN addr 0 Success Comman...

Страница 228: ...d to download drivers and software see http www hp com support To access HP s Guided Troubleshooting website see http www hp com go p2000 Troubleshooting Syntax To show a certain number of events show events detail last a b both error To show events by time show events detail from timestamp to timestamp a b both error To show events by ID show events detail from event event ID to event event ID a ...

Страница 229: ...meter error Shows Warning Error and Critical events Output Date and time when the event was logged Event code identifying the type of event to help diagnose problems for example 181 Event ID prefixed by A or B indicating which controller logged the event for example A123 Model serial number and ID of the controller module that logged the event Severity CRITICAL A failure occurred that may cause a ...

Страница 230: ...230 Alphabetical list of commands See also clear events set snmp parameters show snmp parameters ...

Страница 231: ... 4 lane PHY that communicates between the expander and the SC Ingress Expansion module only 4 lane PHY that communicates between the expander and an expansion port Inter Exp Expansion module only Communicates between the expander and the partner s expander Undefined No status information is available Unused The PHY exists in the expander but is not connected by design Status Enabled Healthy The PH...

Страница 232: ...le enclosure system with an empty disk slot show expander status Encl Ctlr Phy Type Status Elem Status Disabled Reason 1 A 0 Drive Enabled Healthy OK Enabled 1 A 1 Drive Enabled Degraded Non critical Enabled Not ready 1 A 23 Drive Disabled OK Disabled Drive removed 1 A 0 SC 1 Enabled Healthy OK Enabled 1 A 1 SC 1 Enabled Healthy OK Enabled 1 A 0 SC 0 Enabled Healthy OK Enabled 1 A 3 SC 0 Enabled H...

Страница 233: ...HP P2000 G3 MSA System CLI Reference Guide 233 Basetypes sas status controller a status See also clear expander status set expander fault isolation set expander phy ...

Страница 234: ...e back of the enclosure Status Up Warning Error Not Present Unknown Speed Fan speed RPM Position Fan position as viewed from the back of the enclosure Left Right Top Bottom Serial Number blank Not applicable Serial number of a fan in a D2700 enclosure Firmware Version blank Not applicable Firmware revision of a fan in a D2700 enclosure Hardware Version blank Not applicable Hardware revision of a f...

Страница 235: ...n Status Speed Position Serial Number Firmware Version Hardware Version Health Health Reason Health Recommendation Fan Loc left PSU 0 Enclosure 0 Left Up 4959 Left OK Fan Loc right PSU 1 Enclosure 0 Right Up 4959 Right OK Success Command completed successfully 2012 01 18 13 28 22 Basetypes fan status See also show power supplies ...

Страница 236: ...rial number Revision Hardware revision level Dash Level FRU template revision number FRU Shortname Short description Manufacturing Date Date and time in the format year month day hour minutes seconds when a PCBA was programmed or a power supply module was manufactured Manufacturing Location City state province and country where the FRU was manufactured Manufacturing Vendor ID JEDEC ID of the manuf...

Страница 237: ...normally Not Available Status is not available Original SN For a power supply module the original manufacturer serial number otherwise N A Original PN For a power supply module the original manufacturer part number otherwise N A Original Rev For a power supply module the original manufacturer hardware revision otherwise N A Basetypes enclosure sku enclosure fru status ...

Страница 238: ...tor s node name typically the IQN Name Host port nickname Profile Standard The host allows LUN 0 to be assigned to a mapping OpenVMS The host does not allow LUN 0 to be assigned to a mapping HP UX The host allows LUN 0 to be assigned to a mapping and uses Flat Space Addressing Name Name of the volume seen by the host Serial Number Serial number of the volume seen by the host LUN LUN used to access...

Страница 239: ... ID 1A2B3C4D5E6F8900 Name Host2 Profile HP UX Mapping Name Serial Number LUN Access Ports vd2_v2 SN 0 read write A1 A2 B1 B2 vd2_v0 SN 10 read only A1 B1 vd2_v1 SN 11 read write A1 Host View ID 210100E08B33340B Name Host3 Profile Standard Mapping Name Serial Number LUN Access Ports vd2_v2 SN 0 read write A1 A2 B1 B2 vd2_v0 SN 10 read only A1 B1 vd2_v1 SN no access Success Command completed success...

Страница 240: ...connected Either no I O link is detected or the port is not cabled Speed A Actual link speed in Gbit sec Blank if not applicable Speed C Configured host port link speed FC Auto 8Gb 4Gb or 2Gb Gbit sec iSCSI Auto or 1Gb Gbit sec Blank if not applicable Health OK Degraded Fault N A Health Reason If Health is not OK this field shows the reason for the health state Health Recommendation If Health is n...

Страница 241: ...played during failover SIP Netmask iSCSI only Secondary subnet mask IP address This field is only displayed during failover MAC S iSCSI only Secondary MAC address This field is only displayed during failover Example Show port information for a system with two FC ports show host parameters Ports Media Target ID Status Speed A Speed C Health Health Reason Health Recommendation A1 FC L WWPN Up 8Gb Au...

Страница 242: ...n is required IP Ver PIP PIP Gateway PIP Netmask MAC IPv4 10 134 9 101 10 134 0 1 255 255 0 0 00 C0 FF 29 00 23 Success Command completed successfully 2012 01 18 15 03 55 Show port information for a system with two SAS ports show host parameters Ports Media Target ID Status Speed A Health Health Reason Health Recommendation A1 SAS WWPN Up Auto OK Topo C Width Direct 4 A2 SAS WWPN Disconnected Auto...

Страница 243: ...ill be zero if it has not been requested or reset since a controller restart Number of Reads Number of read operations since these statistics were last reset or since the controller was restarted Number of Writes Number of write operations since these statistics were last reset or since the controller was restarted Data Read Amount of data read since these statistics were last reset or since the c...

Страница 244: ... Time Write Resp Time Reset Time hostport_A1 72 0MB 549 45372779 5020328 5947 1GB 657 8GB 0 1517248 1106826 5226569 2012 01 17 21 01 20 Success Command completed successfully 2012 01 18 16 25 41 Basetypes host port statistics status See also reset all statistics reset host port statistics show controller statistics show disk statistics show vdisk statistics show volume statistics show host port st...

Страница 245: ... mapped to any volumes Yes At least one volume is explicitly mapped to the host No No volumes are explicitly mapped to the host Profile Standard The host allows LUN 0 to be assigned to a mapping OpenVMS The host does not allow LUN 0 to be assigned to a mapping HP UX The host allows LUN 0 to be assigned to a mapping and uses Flat Space Addressing Host Type If the host was discovered and its entry w...

Страница 246: ...orageWorks Product ID model SCSI Vendor ID vendor Inquiry Controller A Management Controller Code Version L240R001 Management Controller Loader Code Version 2 5 Storage Controller Code Version T240R01 Storage Controller Loader Code Version 23 008 Serial Number SN MAC Address 00 C0 FF 29 41 60 IP Address 10 134 1 100 Inquiry Controller B Management Controller Code Version Not Present Management Con...

Страница 247: ...bled iSNS IP Address of the iSNS server iSNS Alt IP Address of the alternate iSNS server iSCSI Speed Whether host port link speed is set to auto negotiate auto or to 1 Gbit sec iSCSI IP Version Whether iSCSI host port addresses use IPv4 or IPv6 format Example Show system wide iSCSI parameters show iscsi parameters iSCSI Parameters CHAP Disabled Jumbo Frames Disabled iSNS Disabled iSNS IP 0 0 0 0 i...

Страница 248: ...ade is disabled Enabled Partner firmware upgrade is enabled This is the default Utility Priority Priority at which data redundancy utilities such as vdisk verify and reconstruct run with respect to I O operations competing for the system s processors This does not affect vdisk background scrub which always runs at background priority High Utilities have higher priority than host I O This can cause...

Страница 249: ...ed Temporary license has expired and cannot be renewed Volume Copy Shows whether Volume Copy functions are enabled or disabled Volume Copy Expires Never Always enabled and doesn t expire Replication Shows whether Remote Snap functions are enabled or disabled Replication Expires Never License is purchased and doesn t expire Number of days remaining for a temporary license Expired Temporary license ...

Страница 250: ...e Maximum Snapshots value Licensed Snapshots value In Use Snapshots value Snapshots Expire 2 days remaining Volume Copy Enabled Volume Copy Expires Never Replication Enabled Replication Expires 2 days remaining VDS Enabled VDS Expires Never VSS Enabled VSS Expires Never SRA Enabled SRA Expires Never Success Command completed successfully 2012 10 18 15 07 43 Basetypes license status ...

Страница 251: ...number Name Master volume name Size Total size of the master volume Status Indicates whether the master volume is available or unavailable Status Reason Shows for Available status or a reason for Unavailable status MV Not Accessible Master volume is not accessible MV Not Found Master volume is not found RV Replication volume either a primary volume or a secondary volume RV Prepared Replication pre...

Страница 252: ... Name Snapshots Snap Data Rollback VD1 SN MV1 14 9GB Available SP1 1 1090 5MB VD1 SN MV2 9999 9MB Unavailable SP Not Accessible SP2 0 0B 0 Success Command completed successfully 2012 01 18 15 08 06 Basetypes master volumes status See also convert master to std create master volume delete all master volumes delete master volume expand volume rollback master volume ...

Страница 253: ...ined Either the duplex mode has not been set or it has been unset because the controller module was removed from its enclosure Half The network port duplex mode is set to half duplex Full The network port duplex mode is set to full duplex Auto Negotiation Disabled Either the network port has not been set or it has been unset because the controller module was removed from its enclosure or the port ...

Страница 254: ...9 Gateway 10 134 0 1 Subnet Mask 255 255 0 0 MAC Address value Addressing Mode DHCP Link Speed Unknown Duplex Mode Undefined Auto Negotiation Disabled Health OK Health Reason Health Recommendation Success Command completed successfully 2012 10 29 15 09 03 Show network parameters for a storage system using manual addressing show network parameters Network Parameters Controller A IP Address 172 22 1...

Страница 255: ...ers Controller A IP Address 172 22 1 200 Gateway 172 22 1 1 Subnet Mask 255 255 255 0 MAC Address value Addressing Mode Manual Link Speed 100mbps Duplex Mode Full Auto Negotiation Enabled Network Parameters Controller B IP Address 172 22 1 201 Gateway 172 22 1 1 Subnet Mask 255 255 255 0 MAC Address value Addressing Mode Manual Link Speed Unknown Duplex Mode Undefined Auto Negotiation Disabled Bas...

Страница 256: ...erver IP address or 0 0 0 0 if not set Last Server Contact Date and time in the format year month day hour minutes seconds of the last message received from the NTP server or none Example Show NTP status for the system show ntp status NTP Status NTP Status activated NTP Server Address 69 10 36 3 Last Server Contact 2012 01 18 15 30 44 Success Command completed successfully 2012 01 18 15 39 41 Base...

Страница 257: ...as a problem or is disconnected Speed A Actual host port link speed or blank if not applicable Speed C Configured host port link speed FC Auto 8Gb 4Gb or 2Gb Gbit sec iSCSI Auto or 1Gb Gbit sec Blank if not applicable Health OK Degraded Fault N A Health Reason If Health is not OK this field shows the reason for the health state Health Recommendation If Health is not OK this field shows recommended...

Страница 258: ... Netmask iSCSI only Secondary subnet mask IP address This field is only displayed during failover MAC S iSCSI only Secondary MAC address This field is only displayed during failover Example Show port information for a system with two FC ports show ports Ports Media Target ID Status Speed A Speed C Health Health Reason Health Recommendation A1 FC L WWPN Up 8Gb Auto OK OK Topo C PID Loop 0 A2 FC WWP...

Страница 259: ...ort No action is required IP Ver PIP PIP Gateway PIP Netmask MAC IPv4 10 134 9 101 10 134 0 1 255 255 0 0 00 C0 FF 29 00 23 Success Command completed successfully 2012 01 18 15 03 55 Show port information for a system with two SAS ports show ports Ports Media Target ID Status Speed A Health Health Reason Health Recommendation A1 SAS WWPN Up Auto OK Topo C Width Direct 4 A2 SAS WWPN Disconnected Au...

Страница 260: ...ult Unknown Health Reason If Health is not OK this field shows the reason for the health state Health Recommendation If Health is not OK this field shows recommended actions to take to resolve the health issue Example Show power supply information show power supplies Encl Serial Number Name Health Health Reason Health Recommendation 1 SN PSU 1 Left OK 1 SN PSU 2 Right OK Success Command completed ...

Страница 261: ... Snapshot The latest snapshot that is copy complete on all secondary volumes It identifies a common point in time that is known by all destinations Only Sync Point Snapshot The only sync point that is available on at least one secondary volume If this snapshot is removed then the next replication requires a full sync to be performed Queued Snapshot A snapshot that was taken for remote replication ...

Страница 262: ...otocols show protocols Service and Security Protocols Web Browser Interface HTTP Enabled Secure Web Browser Interface HTTPS Enabled Command Line Interface Telnet Enabled Secure Command Line Interface SSH Enabled Storage Management Initiative Specification SMI S Enabled Unsecure Storage Management Initiative Specification SMI S 5988 Disabled File Transfer Protocol FTP Disabled Simple Network Manage...

Страница 263: ...erational Operational but not redundant In active active mode one controller is operational and the other is offline In single controller mode the controller is operational Down This controller is not operational Unknown Status information is not available Controller ID Status Operational The controller is operational Down The controller is installed but not operational Not Installed The controlle...

Страница 264: ...where both controllers are down show redundancy mode System Redundancy Controller Redundancy Mode Down Controller Redundancy Status Down Controller A Status Down Controller A Serial Number SN Controller B Status Down Controller B Serial Number SN Success Command completed successfully 2012 02 01 11 03 39 Show the redundancy status of a single controller system show redundancy mode System Redundanc...

Страница 265: ...pe was last updated The value 0 means the data has never been updated and is not cached A value other than 0 is a timestamp indicating that the data has been updated If the value has changed since the last time you called this command then the data has changed Syntax show refresh counters Basetypes refresh counters status See also set cli parameters ...

Страница 266: ...show remote systems System2 Remote System System Name System2 System Contact J Smith System Location Denver lab System Information Uninitialized Info Vendor Name vendor Product ID product Product Brand brand IP Address Controller A 10 122 1 21 IP Address Controller B 10 122 1 22 Username manage Status Connected Last Connected 2012 01 18 12 58 15 Success Command completed successfully 2012 01 18 15...

Страница 267: ...mage Name User defined name assigned to the primary image Snapshot Serial Replication snapshot serial number associated with the image The replication snapshot is associated with the replication volume specified in the request Snapshot Name Replication snapshot name associated with the image For a secondary image this value is not filled in until the replication is completed Creation Date Time Dat...

Страница 268: ...umber Type vd01_v001 SN Primary Volume Image Serial Number Image Name Snapshot Serial Snapshot Name Creation Date Time SN vd01_v001_i01 SN vd01_v001_i01 2012 01 18 14 24 33 SN vd01_v001_i02 SN vd01_v001_i02 2012 01 18 14 25 33 rvd01_v001 SN Secondary Volume Image Serial Number Image Name Snapshot Serial Snapshot Name Creation Date Time SN vd01_v001_i01 SN Snap12319447290 2012 01 18 14 52 09 Status...

Страница 269: ...HP P2000 G3 MSA System CLI Reference Guide 269 Basetypes replication volume summary status See also show replication sets show replication volumes ...

Страница 270: ...em in preparation for replication Status Reason More information about the status value or N A for Online status Monitor Replication volume monitoring status OK Communication to the remote volume is successfully occurring on the FC or iSCSI network Failed Communication to the remote volume has failed because of an FC or iSCSI network issue or because the remote volume has gone offline Location Rep...

Страница 271: ...ication with the remote volume or N A Remote link information Connected Ports For a remote primary or secondary volume this field shows the IDs of up to two hosts ports in the local system that are connected to the remote system If two ports are connected but only one is shown this indicates that a problem is preventing half the available bandwidth from being used For a local primary or secondary ...

Страница 272: ...or Interval Priority Connection Status Connection Time rData SN Online N A OK Remote Data SN Online 32 1800 Retry FC Oldest 300 Medium Online 2012 01 18 10 33 38 Connected Ports Remote Address A1 FCPortWWN 207000c0ff000991 FCPortWWN 217000c0ff000991 FCPortWWN 247000c0ff000991 A1 FCPortWWN 257000c0ff000991 Data SN Online N A OK Local Data SN Online 32 1800 Retry FC Oldest 300 Medium Not Attempted N...

Страница 273: ...volume is online and replication is in progress Replicate delay The volume is online but the in progress replication has been temporarily delayed a retry is occurring Suspended The volume is online but the in progress replication has been suspended Offline The volume can be accessed but is unusable due to an error Establishing proxy The volume is establishing a proxy connection to a remote volume ...

Страница 274: ...test replication image should be considered for the next replication operation Oldest Only the latest n replication images should be considered for the next replication operation where n is defined by the MaxQueue value and the oldest of these images should be considered first This is the default Monitor Interval Interval in seconds at which the primary volume should query the secondary volume The...

Страница 275: ...Status Status Reason Monitor Location Primary Volume Primary Volume Serial Primary Volume Status MaxQueue MaxRetryTime On Error Link Type On Collision Monitor Interval Priority Connection Status Connection Time vd01_v001 SN Online N A OK Remote vd01_v001 SN Online 32 1800 Retry iSCSI Oldest 300 Medium Online 2018 01 18 10 04 00 Connected Ports Remote Address A1 IP 10 134 9 46 3260 IP 10 134 9 47 3...

Страница 276: ...ler module or expansion module Name Out Port Egress expansion port on controller module or an expansion module Can be connected to an ingress port on an expansion module In Port Ingress port on an expansion module Can be connected to an egress expansion port on a controller module or an expansion module Status Up Disconnected Not Present Warning Error Unknown Health OK Degraded Fault N A Unknown ...

Страница 277: ...Out Port Disconnected N A No drive enclosure is connected to this expansion port This is normal if this is the last or only enclosure in the cabling sequence of the system No action is required 2 A In Port Up OK 2 B Out Port Disconnected N A No drive enclosure is connected to this expansion port This is normal if this is the last or only enclosure in the cabling sequence of the system No action is...

Страница 278: ...Schedule Specification Start 2011 10 19 23 47 00 Every 3 Minutes Status Ready Next Time 2011 10 23 12 59 00 Task To Run Snap Error Message Tasks Task Name Snap Task Type TakeSnapshot Status Ready Task State Start Error Message Task Details Source Volume VD1_V1 Source Volume Serial SN Prefix VD1_V1 Count 4 Last Created VD1_V1_S0001 Snapshot Name Snapshot Serial VD1_V1_S0001 SN Success Command compl...

Страница 279: ...e TakeSnapshot Status Ready Task State Start Error Message Task Details Source Volume VD1_V1 Source Volume Serial SN Prefix VD1_V1 Count 4 Last Created VD1_V1_S0001 Snapshot Name Snapshot Serial VD1_V1_S0001 SN Schedule Name bTx_v002_sched1 Schedule Specification Start 2011 10 03 11 13 00 Every 1 Hours Count 30 Status Expired Next Time 2011 10 04 17 13 00 Task To Run bTx_v002_task001 Error Message...

Страница 280: ...21 SN bTx_v002_01_R0022 SN bTx_v002_01_R0023 SN bTx_v002_01_R0024 SN bTx_v002_01_R0025 SN bTx_v002_01_R0026 SN bTx_v002_01_R0027 SN bTx_v002_01_R0028 SN bTx_v002_01_R0029 SN bTx_v002_01_R0030 SN Success Command completed successfully 2011 10 10 15 20 05 Basetypes schedules status See also create schedule delete schedule show schedule details ...

Страница 281: ...etected a non critical error condition Temperature voltage or current is between the warning and critical thresholds Error The sensor detected a critical error condition Temperature voltage or current exceeds the critical threshold Unavailable The sensor is present with no known errors but has not been turned on or set into operation because it is initializing This typically occurs during controll...

Страница 282: ...mperature Loc right PSU 34 C OK 1 Voltage 12V Loc upper IOM A 11 92 OK 1 Voltage 5V Loc upper IOM A 5 10 OK 1 Voltage 12V Loc lower IOM B 11 98 OK 1 Voltage 5V Loc lower IOM B 5 10 OK 1 Voltage 12V Loc left PSU Error 1 Voltage 5V Loc left PSU Error 1 Voltage 3 3V Loc left PSU Error 1 Voltage 12V Loc right PSU 12 49 OK 1 Voltage 5V Loc right PSU 5 58 OK 1 Voltage 3 3V Loc right PSU 3 60 OK 1 Curren...

Страница 283: ...ow shutdown status Output Message stating whether each controller is up active down shut down or not installed Example Show the shutdown status of each controller show shutdown status Storage Controller A up Storage Controller B down Success Command completed successfully 2011 10 10 15 26 37 Basetypes shutdown status status See also restart shutdown ...

Страница 284: ... snap pool is available for use Offline The snap pool is not available for use as in the case where its disks are not present Corrupt The snap pool s data integrity has been compromised the snap pool can no longer be used Threshold Snap pool threshold level Warning The snap pool is moderately full When this threshold is reached an event is generated to alert the administrator The default is 75 Err...

Страница 285: ...napshot that is not a current sync point will be deleted This behavior occurs for each snap pool independently based on its space usage deleteoldestsnapshot Delete the oldest snapshot deletesnapshots Delete all snapshots haltwrites Halt writes to the snap pool notifyonly Generates an event to notify the administrator SizeToExpand size For the autoexpand policy the size by which to automatically ex...

Страница 286: ...and syntax on page 22 type standard replication all Optional Shows only standard non replication snapshots only replication snapshots or snapshots of all types If this parameter is omitted snapshots of all types are shown Output Vdisk Vdisk name Serial Number Snapshot serial number Name Snapshot name Creation Date Time Date and time the snapshot was prepared or committed Status Available Unavailab...

Страница 287: ... the replication set Replication snapshot Old Common sync point For a primary or secondary volume a common sync point that has been superseded by a new common sync point Replication snapshot Only sync point For a primary or secondary volume the only snapshot that is copy complete on any secondary system in the replication set Replication snapshot Queued For a primary volume a snapshot associated w...

Страница 288: ...288 Alphabetical list of commands Basetypes snapshots status See also show master volumes show snap pools ...

Страница 289: ...s are disabled SNMP Trap Host IP IP address of each trap host SNMP read community Community string for read only access not shown to Monitor users SNMP write community Community string for write access not shown to Monitor users Example Show SNMP notification settings show snmp parameters SNMP Trap Notification Level crit SNMP Trap Host IP1 172 22 4 171 SNMP Trap Host IP2 0 0 0 0 SNMP Trap Host IP...

Страница 290: ...iption of what the system is used for or how it s configured The default is Uninitialized Info Midplane Serial Number The serial number of the controller enclosure midplane Vendor Name Vendor name Product ID Product model identifier Product Brand Product brand name SCSI Vendor ID Vendor name returned by the SCSI INQUIRY command SCSI Product ID Product identifier returned by the SCSI INQUIRY comman...

Страница 291: ...tion System Name Storage 2 System Contact J Smith System Location Main lab System Information Used for testing Midplane Serial Number SN Vendor Name vendor Product ID product Product Brand brand SCSI Vendor ID vendor ID SCSI Product ID product ID Enclosure Count 1 Health Degraded Health Reason See the information about unhealthy components for guidance Supported Locales English Spanish French Germ...

Страница 292: ...292 Alphabetical list of commands Basetypes system unhealthy component status See also set system ...

Страница 293: ...Enabled Shows whether host profiles are enabled which determines whether LUN 0 can be assigned to volume mappings Number of Host Ports Number of host interface ports in the controller enclosure Maximum Disks Number of disks that the system supports Maximum Volumes Number of volumes that the system supports Maximum Vdisks Number of vdisks that the system supports Maximum LUNs Number of LUNs that th...

Страница 294: ...294 Alphabetical list of commands See also set volume set vdisk ...

Страница 295: ...eLicensingLimit CreateName CreateSnap VerifySnap InspectRetention FindOldestSnap UnmapSnap ResetSnap RenameSnap Error Message Message if an error occurred while processing the task or blank Source Volume Standard or master volume name Source Volume Serial Volume serial number Prefix Label that identifies snapshots created by this task Snapshot names have the format prefix_s where starts at 001 Cou...

Страница 296: ...Invalid Task is invalid Task State Current step of the task Start VerifySnap UnmapSnap ResetSnap Error Message Message if an error occurred while processing the task or blank Snapshot Name Name of the snapshot to reset Snapshot Serial Number Serial number of the snapshot to reset For a VolumeCopy task Task Name Task name Task Type VolumeCopy Status Uninitialized Task is not yet ready to run Ready ...

Страница 297: ...destination vdisk Destination Vdisk Serial Serial number of the destination vdisk Prefix Label that identifies copies created by this task Volume names have the format prefix_c where starts at 001 Modified Data modified The copy includes modified snapshot data preserved The copy excludes modified snapshot data Last Created Name of the last volume created by the task or blank For a ReplicateVolume ...

Страница 298: ...hot of the primary volume last snapshot Replicate the last most recent existing snapshot of the primary volume Last Created Name of the last volume created by the task or blank Last Used Snapshot For a task whose replication mode is last snapshot the name of the last snapshot used for replication otherwise N A For an EnableDSD task Task Name Task name which must be taskDSDresume Task Type EnableDS...

Страница 299: ...ssage Message if an error occurred while processing the task or blank Example Show information about task Snap show task details Snap Tasks Task Name Snap Task Type TakeSnapshot Status Ready Task State Start Error Message Task Details Source Volume MV Source Volume Serial SN Prefix MV Count 1 Last Created MV_S0001 Snapshot Name Snapshot Serial MV_S0001 SN Success Command completed successfully 201...

Страница 300: ...on FindOldestSnap UnmapSnap ResetSnap RenameSnap Error Message Message if an error occurred while processing the task or blank Source Volume Standard or master volume name Source Volume Serial Volume serial number Prefix Label that identifies snapshots created by this task Snapshot names have the format prefix_s where starts at 001 Count Number of snapshots to retain with this prefix When a new sn...

Страница 301: ...tSnap Error Message Message if an error occurred while processing the task or blank Snapshot Name Name of the snapshot to reset Snapshot Serial Number Serial number of the snapshot to reset For a VolumeCopy task Task Name Task name Task Type VolumeCopy Status Uninitialized Task is not yet ready to run Ready Task is ready to run Active Task is running Error Task has an error Invalid Task is invalid...

Страница 302: ...e copy excludes modified snapshot data Last Created Name of the last volume created by the task or blank For a ReplicateVolume task Task Name Task name Task Type ReplicateVolume Status Uninitialized Task is not yet ready to run Ready Task is ready to run Active Task is running Error Task has an error Invalid Task is invalid Task State Current step of the task Start VerifyVolume CreateName RepVolum...

Страница 303: ...e Task Type EnableDSD Status Uninitialized Task is not yet ready to run Ready Task is ready to run Active Task is running Error Task has an error Invalid Task is invalid Task State Current step of the task always Start Error Message Message if an error occurred while processing the task or blank For a DisableDSD task Task Name Task name which must be taskDSDsuspend Task Type DisableDSD Status Unin...

Страница 304: ... Last Created MV_S0001 Snapshot Name Snapshot Serial MV_S0001 SN Task Name Reset Task Type ResetSnapshot Status Ready Task State Start Error Message Task Details Snapshot Name VD1_V1_S0001 Snapshot Serial Number SN Task Name Copy Task Type VolumeCopy Status Ready Task State Start Error Message Task Details Source Volume VD1_V1 Source Volume Serial SN Destination Vdisk VD2 Destination Vdisk Serial ...

Страница 305: ...st Created MV_S0001 Last Used Snapshot Snapshot Name Snapshot Serial MV_S0001 SN Task Name taskDSDresume Task Type EnableDSD Status Ready Task State Start Error Message Task Name taskDSDsuspend Task Type DisableDSD Status Ready Task State Start Error Message Success Command completed successfully 2012 01 19 15 28 52 Basetypes tasks status See also create schedule create task delete task set task s...

Страница 306: ...sks must be brought online If the data is not needed it can be cleared in which case it will be lost and data will differ between the host and disk Syntax show unwritable cache Example Show the percentage of unwritable cache data in the system show unwritable cache Unwritable System Cache Percent of unwritable cache in controller A 0 Percent of unwritable cache in controller B 0 Success Command co...

Страница 307: ...x The user can access the file transfer protocol interface blank The user cannot access this interface This is the default SMI S x The user can access the Storage Management Initiative Specification SMI S interface blank The user cannot access this interface This is the default SNMP U The user can access the SNMPv3 interface and view the MIB T The user can access the SNMPv3 interface and receive t...

Страница 308: ...ow users Username Roles User Type User Locale WBI CLI FTP SMI S SNMP Authentication Type Privacy Type Password Privacy Password Trap Host Address ftp manage monitor Standard English x MIB monitor Standard English U SHA AES access_MIB MIB_access manage manage monitor Standard English x x x x monitor monitor Standard English x x Traps monitor Standard English T SHA AES _Abc123_ _123Abc_ 172 22 4 171...

Страница 309: ...isk name Size Vdisk size Free Vdisk free space Own Either the preferred owner during normal operation or the partner controller when the preferred owner is offline Pref Controller that owns the vdisk and its volumes during normal operation RAID Vdisk RAID level Disks Number of disks in the vdisk Spr Number of spares assigned to the vdisk Chk For RAID levels except NRAID RAID 1 and RAID 50 the conf...

Страница 310: ...e vdisk is offline with multiple inaccessible disks causing user data to be incomplete or is an NRAID or RAID 0 vdisk STOP The vdisk is stopped UNKN Unknown UP Up The vdisk is online and does not have fault tolerant attributes Jobs Shows whether a job is running and its percent complete DRSC The disk is being scrubbed EXPD The vdisk is being expanded INIT The vdisk is initializing RCON The vdisk i...

Страница 311: ...lth Reason Health Recommendation VD1 587 1GB 116 7GB B B RAID50 6 0 64k FTOL VRSC 41 SN Disabled 0 OK VD2 146 5GB 95 7GB A A RAID0 2 0 64k UP SN Enabled all spinning 15 OK VD3 900 1GB 900 1GB B B RAID1 2 0 N A OFFL INIT 2 SN Disabled 0 OK Success Command completed successfully 2012 01 19 15 31 35 Show information for all vdisks with performance statistics fields show vdisks perf Name Size Free Own...

Страница 312: ...in live output This is caused by a difference in the way that historical and live values are calculated Live values are calculated based on the vdisk as viewed from the controller cache perspective In the live statistics performance numbers are obtained by accounting for when data is written from cache to disk or is read from disk to cache Historical data is obtained by using the summation of the ...

Страница 313: ...istics were last requested or reset This value will be zero if it has not been requested or reset since a controller restart IOPS Input output operations per second calculated over the interval since these statistics were last requested or reset This value will be zero if it has not been requested or reset since a controller restart Number of Reads Number of read operations since these statistics ...

Страница 314: ...month day hour minutes seconds when the data sample was taken Example Show live statistics for vdisks VD1 and MyVdisk show vdisk statistics VD1 MyVdisk Name Serial Number Bytes per second IOPS Number of Reads Number of Writes Data Read Data Written I O Resp Time Read Resp Time Write Resp Time Reset Time VD1 SN 22 0MB 82 6179839 10507038 478 8GB 1024 4GB 156240 12699 240665 2011 01 17 08 15 01 MyVd...

Страница 315: ...d Data Written Total Bps Read Bps Write Bps Sample Time 44 8GB 22 4GB 22 4GB 49 8MB 24 9MB 24 9MB 2012 01 19 11 30 00 Success Command completed successfully 2012 01 19 12 35 06 Basetypes vdisk statistics live virtual disk summary historical status See also reset all statistics reset vdisk statistics show controller statistics show disk statistics show host port statistics show vdisks show volume s...

Страница 316: ...ial number Vdisk Destination vdisk name Source Volume Source volume name Progress Percent complete of the volume copy Status Unavailable A volume copy is in progress to the destination volume Suspended The source volume went offline while a volume copy was in progress When the source volume comes back online the copy process resumes from the point where it stopped Status Reason More information ab...

Страница 317: ...the volume to a host Blank if not mapped or mapped as no access Access Type of host access to the volume read write The host has read and write access to the volume This is the default read only The host has read access to the volume no access The host is denied access to the volume not mapped The host is not mapped to the volume Host Port Identifier FC and SAS Host WWPN iSCSI Host initiator node ...

Страница 318: ... write all other hosts Standard Volume View Serial Number SN Name v2 Mapping Ports LUN Access Host Port Identifier Nickname Profile A1 B1 101 read write 207000c0ff001121 Host2 Standard A1 100 read only 207000c0ff001122 Host1 Standard not mapped all other hosts Standard Success Command completed successfully 2012 01 19 15 33 50 Basetypes volume view status See also show host maps show hosts show vo...

Страница 319: ...Names or serial numbers of the volumes to show information about For volume syntax see Command syntax on page 22 If this parameter is omitted information is shown for all volumes Output Name Name of the volume Serial Number Volume serial number Example Show volume names and serial numbers show volume names Name Serial Number Data SN Data_s001 SN spData SN vd1_v1 SN Success Command completed succes...

Страница 320: ...es or serial numbers of specific volumes For volume syntax Command syntax on page 22 Output Name Name of the volume Serial Number Volume serial number Volume Reserved Free The volume is not reserved Reserved The volume has been reserved by a host Host ID Host WWPN or iSCSI node name Port Controller ID and port number Reservation Type Write Exclusive Write commands are only allowed for a single res...

Страница 321: ...how volume reservations all Name Serial Number Volume Reserved Host ID Port Reservation Type vd04_v001 SN Free Undefined vd04_v002 SN Reserved iqn 1991 05 com microsoft andiamo A3 Exclusive Access Success Command completed successfully 2012 01 19 08 58 28 See also release volume show volumes ...

Страница 322: ...or volume syntax see Command syntax on page 22 Output Vdisk Name of the vdisk Name Name of the volume Size Volume size Serial Number Volume serial number WR Policy Cache write policy write back Write back caching does not wait for data to be completely written to disk before signaling the host that the write is complete This is the default and preferred setting for a fault tolerant environment bec...

Страница 323: ...cation specific volume such as a standard volume master volume snapshot or snap pool RSR Replication specific volume such as a primary volume secondary volume replication snapshot or replication image RSR DRM Promoted Secondary During an actual site failover not a test failover the replication set s primary and secondary volumes are shown as primary volumes with a primary volume conflict This qual...

Страница 324: ...ard N A WWN OK Success Command completed successfully 2012 01 19 15 34 46 Show volume information for vdisk VD1 only show volumes vdisk VD1 Vdisk Name Size Serial Number WR Policy Cache Opt Read Ahead Size Type Class Qualifier Volume Description WWN Health Health Reason Health Recommendation VD1 V1 35 9GB SN write back standard Default standard standard N A WWN OK VD1 V2 35 9GB SN write back stand...

Страница 325: ...ns per second calculated over the interval since these statistics were last requested or reset This value will be zero if it has not been requested or reset since a controller restart Number of Reads Number of read operations since these statistics were last reset or since the controller was restarted Number of Writes Number of write operations since these statistics were last reset or since the c...

Страница 326: ...326 Alphabetical list of commands See also reset all statistics reset volume statistics show controller statistics show disk statistics show host port statistics show vdisk statistics show volumes ...

Страница 327: ...before removing a controller module or powering down the system CAUTION You can continue to use the CLI when either or both Storage Controllers are shut down but information shown might be invalid Syntax shutdown a b both Parameters a b both Optional Specifies to shut down the Storage Controller in controller A B or both If this parameter is omitted the command affects the controller being accesse...

Страница 328: ...is configured to use FC links the secondary system must have FC ports 2 In the secondary system a Start the snap pools vdisks b Start the secondary volumes vdisks c Reattach the secondary volumes NOTE If the replication set was deleted before the secondary volume was reattached you can clean up this remnant by reattaching the secondary volume setting it to be the primary volume by using the set re...

Страница 329: ...ary volumes that it contains are detached When a vdisk is stopped The volumes in the vdisk become inaccessible to hosts Its cached data is flushed to disk Removing its disks will not cause the system to report errors or to attempt reconstruction NOTE You cannot stop a vdisk that contains a primary volume NOTE If a secondary volume and its snap pool are in different vdisks you cannot stop the snap ...

Страница 330: ...spend replication set replication set replication volume Parameters set replication set Optional Name or serial number of the replication set replication volume Name or serial number of the secondary volume If the name is not unique across replication sets specify the set parameter Example Suspend replication of primary volume V1 to secondary volume rV1 suspend replication rV1 Success Command comp...

Страница 331: ...figured to receive them such as email SNMP and SMI S Event 312 snmp This option behaves the same as the notification option and remains for backward compatibility only region crash1 crash2 crash3 crash4 ecdebug mc scdebug Optional For use with the managed logs feature this parameter specifies the log type debug data region to send a notification about crash1 crash2 crash3 or crash4 Specify one of ...

Страница 332: ...g this procedure consult the online troubleshooting guide at https www hp com go p2000 troubleshooting to determine if the trust operation is applicable to your situation and for guidance to perform it CAUTION 1 Do not use the trust command when the storage system is unstable for example if there are many power or topology change events 2 The trust command cannot be run on a quarantined vdisk In m...

Страница 333: ...place the failed disks with new disks 5 Re create the vdisk 6 Restore the data from the backup performed in step 2 7 Restore original vdisk ownership 8 Re enable background scrub operations Syntax trust enable disable vdisk vdisk unsafe Parameters enable disable Optional enable Enables the trust command before use disable Disables the trust command if it is not used after being enabled If trust is...

Страница 334: ...disk which has enough good disks to complete the trust operation The vdisk may have out of sync or partially reconstructed disks but they are not needed to complete the trust operation The command completes successfully trust enable Success Command completed successfully Trust is enabled 2013 09 17 04 29 28 trust vdisk VD1 Success Command completed successfully VD1 Trust operation completed succes...

Страница 335: ...st operation completed successfully for this vdisk 2013 09 17 09 07 31 Abort an unsafe trust operation when you decide not to risk using bad disks trust enable Success Command completed successfully Trust is enabled 2013 09 17 09 05 37 trust vdisk vdr5 Location Serial Number Type State Partially Reconstructed Out Of Sync Age 1 2 SN SAS LEFTOVR False True 6 1 4 SN SAS VDISK False False 7 1 5 SN SAS...

Страница 336: ...node name typically the IQN or nickname of each initiator to unmap the volumes from If the host parameter is omitted mapping changes apply to all hosts not explicitly mapped that is to the default mapping volumes Names or serial numbers of the volumes to unmap For volume syntax see Command syntax on page 22 Example Delete explicit mappings of Host1 to volumes V1 and V3 leaving the default mappings...

Страница 337: ... s name or the IP address of one of its controller network ports If this parameter is omitted links between the local controllers are verified link type FC iSCSI ALL Optional Specifies the type of host port links to verify FC Verify FC to FC links only iSCSI Verify iSCSI to iSCSI links only ALL Verify all FC to FC and iSCSI to iSCSI links If this parameter is omitted all links are verified Output ...

Страница 338: ...338 Alphabetical list of commands Basetypes remote links See also show remote systems verify remote link ...

Страница 339: ...f one of its controller network ports link type FC iSCSI ALL Optional Specifies the type of host port links to verify FC Verify FC to FC links only iSCSI Verify iSCSI to iSCSI links only ALL Verify all FC to FC and iSCSI to iSCSI links If this parameter is omitted all links are verified Output Port Port ID on the local system Type FC FC port iSCSI iSCSI port Offline Port is disconnected Links IDs ...

Страница 340: ...340 Alphabetical list of commands Basetypes remote links See also show remote systems verify links ...

Страница 341: ...complete event 21 is logged and specifies the number of inconsistencies found Such inconsistencies can indicate that a disk in the vdisk is going bad TIP Unless you want to verify without fixing errors it is better to use the scrub vdisk command which operates similarly to verify vdisk but also can find and fix media errors for any RAID level including NRAID and RAID 0 Syntax verify vdisk vdisks f...

Страница 342: ...d version information for each controller versions detail Controller A Versions Storage Controller CPU Type value Bundle Version value Build Date value Storage Controller Code Version value Storage Controller Code Baselevel value Memory Controller FPGA Code Version value Storage Controller Loader Code Version value CAPI Version value Management Controller Code Version value Management Controller L...

Страница 343: ...a is to be included in the copy and the snapshot is mounted presented mapped and I O is occurring to it To ensure the integrity of a copy of a master volume unmount unpresent unmap the volume or at minimum perform a system cache flush and refrain from writing to the volume Since the system cache flush is not natively supported on all operating systems it is recommended to unmount unpresent unmap t...

Страница 344: ...n vdisk For volume syntax see Command syntax on page 22 Example Copy master volume MV1 to new volume MV1copy on vdisk VD2 volumecopy source volume MV1 dest vdisk VD2 MV1copy The source volume MUST be unmounted from all hosts prior to starting a volume copy Ready to continue yes Success Command completed successfully MV1 The volume copy started 2012 01 20 12 02 02 show volumes Vdisk Name Type VD2 M...

Страница 345: ...hat are for internal use only Each basetype topic includes the following information For each property the values of its name and type elements and a description of the values that the property may show For descriptions of other elements see Table 3 on page 19 Example output from a command that uses the basetype Some basetypes are used by multiple commands Examples in this chapter were generated u...

Страница 346: ...ng Priority at which data redundancy utilities such as vdisk verify and reconstruct run with respect to I O operations competing for the system s processors This does not affect vdisk background scrub which always runs at background priority High Utilities have higher priority than host I O Use when your highest priority is to return the system to a fully fault tolerant state This can cause heavy ...

Страница 347: ...specified volume is flushed to disk sync cache mode numeric string Numeric equivalents for sync cache mode values 0 Immediate 1 Flush to Disk independent cache string Shows the cache redundancy mode for a dual controller storage system Not supported Disabled by default independent cache numeric string Numeric equivalents for independent cache values 0 Disabled 1 Enabled missing lun response string...

Страница 348: ... power supply failure trigger is enabled power supply failure numeric string Numeric equivalents for power supply failure values 0 Disabled 64 Enabled fan failure string Shows whether the cache policy will change from write back to write through when a fan fails Disabled The fan failure trigger is disabled This is the default Enabled The fan failure trigger is enabled fan failure numeric string Nu...

Страница 349: ...tarting again is 72 hours Disabled Background disk scrub is disabled This is the default Enabled Background disk scrub is enabled background disk scrub numeric string Numeric equivalents for background disk scrub values 0 Disabled 1 Enabled managed logs string Shows whether the managed logs feature is enabled which allows log files to be transferred from the storage system to a log collection syst...

Страница 350: ...ller failure type string Enabled PROPERTY PROPERTY name controller failure numeric type string 16 PROPERTY PROPERTY name super cap failure type string Enabled PROPERTY PROPERTY name super cap failure numeric type string 4 PROPERTY PROPERTY name compact flash failure type string Enabled PROPERTY PROPERTY name compact flash failure numeric type string 512 PROPERTY PROPERTY name power supply failure ...

Страница 351: ...format rows PROPERTY name attribute name type string Only Sync Point Snapshot PROPERTY PROPERTY name priority value type string 0xe000 default PROPERTY Table 10 attribute priorities properties Name Type Description attribute name string Snapshot retention attribute Standard Snapshot Volume Copy Snapshot A snapshot that is being used to copy data from a source volume to a destination volume This at...

Страница 352: ...tribute name type string Queued Snapshot PROPERTY PROPERTY name priority value type string 0x2000 default PROPERTY OBJECT OBJECT basetype attribute priorities name attribute priorities oid 8 format rows PROPERTY name attribute name type string DRM Snapshot PROPERTY PROPERTY name priority value type string 0xb000 default PROPERTY OBJECT ...

Страница 353: ...OST Power On Self Test fails during POST or fails during controller operation Disabled The CompactFlash failure trigger is disabled Enabled The CompactFlash failure trigger is enabled This is the default power supply failure string Shows whether the cache policy will change from write back to write through when a power supply fails Disabled The power supply failure trigger is disabled This is the ...

Страница 354: ...PI basetype properties PROPERTY name temperature exceeded type string Enabled PROPERTY PROPERTY name partner notify type string Disabled PROPERTY PROPERTY name auto write back type string Enabled PROPERTY OBJECT ...

Страница 355: ...ing Numeric equivalents for write policy values 0 write through 1 write back cache optimization string If a volume is specified its cache optimization mode standard Optimizes cache for both sequential and random reads Appropriate for applications that read and write small files in random order such as transaction based and database update applications This is the default cache optimization numeric...

Страница 356: ...me volume name type string vd02_v001 PROPERTY PROPERTY name write policy type string write back PROPERTY PROPERTY name write policy numeric type string 1 PROPERTY PROPERTY name cache optimization type string standard PROPERTY PROPERTY name cache optimization numeric type string 0 PROPERTY PROPERTY name read ahead size type string Default PROPERTY PROPERTY name read ahead size numeric type string 1...

Страница 357: ...ng The system s operating mode also called the cache redundancy mode Active Active ULP Both controllers are active using ULP Unified LUN Presentation Data for volumes configured to use write back cache is automatically mirrored between the two controllers to provide fault tolerance Single Controller There is only a single controller in the enclosure Fail Over Operation has failed over to one contr...

Страница 358: ...ECT Table 14 certificate status properties Name Type Description certificate status string Default No customer supplied or alternate certificate has been installed Customer supplied A custom or alternate certificate has been installed certificate status numeric string Numeric equivalents for certificate status values 0 Default 1 Customer supplied certificate time string Date and time in the format...

Страница 359: ...est1secret PROPERTY PROPERTY name oname type string PROPERTY PROPERTY name osecret type string PROPERTY OBJECT Table 15 chap records properties Name Type Description initiator name string Originator name typically the originator s IQN initiator secret string Secret that the recipient uses to authenticate the originator oname string For mutual CHAP the recipient name osecret string For mutual CHAP ...

Страница 360: ...pa Alternate form of XML output for internal use only json Alternate data interchange format for internal use only output format api string console api api brief api embed api embed brief json json full output format api numeric string Numeric equivalents for output format api values 1 console 2 api 3 api brief 4 api embed 5 api embed brief 6 json 7 json full brief mode string Enabled In XML outpu...

Страница 361: ... precision uint8 Number of decimal places 1 10 for display of storage space sizes The default is 1 storage size units string Unit for display of storage space sizes Auto Lets the system determine the proper unit for a size This is the default MB Sizes are shown in megabytes GB Sizes are shown in gigabytes TB Sizes are shown in terabytes Based on the precision setting if a size is too small to mean...

Страница 362: ...ge size precision type uint8 2 PROPERTY PROPERTY name storage size units type string Auto PROPERTY PROPERTY name storage size units numeric type string 0 PROPERTY PROPERTY name temperature scale type string Celsius PROPERTY PROPERTY name temperature scale numeric type string 1 PROPERTY PROPERTY name ui refresh type uint16 30 PROPERTY PROPERTY name user type type string Standard PROPERTY PROPERTY n...

Страница 363: ... A Ctlr B CF CompactFlash card in controller B controller id string A Controller A B Controller B controller id numeric string Numeric equivalents for controller id values 0 B 1 A name string Controller A CompactFlash Controller B CompactFlash status string Not Installed Installed status numeric string Numeric equivalents for status values 0 Not Installed 1 Installed cache flush string Enabled If ...

Страница 364: ...364 XML API basetype properties PROPERTY name health numeric type string 0 PROPERTY PROPERTY name health reason type string PROPERTY PROPERTY name health recommendation type string PROPERTY OBJECT ...

Страница 365: ...The current system wide cache policy as determined by auto write through AWT logic This value is not settable by users If an AWT trigger condition such as a CompactFlash failure is met the cache policy for all volumes changes to write through overriding the volume specific settings When the problem is corrected the cache policy reverts to the value configured for each individual volume Enabled Wri...

Страница 366: ...type string 0 PROPERTY PROPERTY name compact flash status type string Installed PROPERTY PROPERTY name compact flash status numeric type string 1 PROPERTY PROPERTY name cache flush type string Enabled PROPERTY PROPERTY name cache flush numeric type string 1 PROPERTY OBJECT ...

Страница 367: ...rld Wide Node Name WWNN ip address string Controller network port IP address ip subnet mask string Controller network port IP subnet mask ip gateway string Controller network port gateway IP address disks uint32 Number of disks in the storage system virtual disks uint32 Number of vdisks in the storage system cache memory size uint32 Controller cache memory size MB host ports uint32 Number of host ...

Страница 368: ...u speed sint32 Storage Controller processor speed internal serial number string Internal serial number of the controller cache lock string Shows whether hosts are prevented from using the SCSI MODE SELECT command to change the storage system s write back cache setting No Hosts are permitted to disable write back cache Yes Hosts are prevented from disabling write back cache This is the default cach...

Страница 369: ...m slot position numeric string Numeric equivalents for position values 0 Top 1 Bottom phy isolation string Shows whether the automatic disabling of SAS expander PHYs having high error counts is enabled or disabled for this controller Enabled PHY fault isolation is enabled This is the default Disabled PHY fault isolation is disabled phy isolation numeric string Numeric equivalents for phy isolation...

Страница 370: ...type string 0 PROPERTY PROPERTY name fail over reason type string Not applicable PROPERTY PROPERTY name fail over reason numeric type string 0 PROPERTY PROPERTY name sc fw type string T240R14 01 PROPERTY PROPERTY name vendor type string vendor PROPERTY PROPERTY name model type string model PROPERTY PROPERTY name sc cpu type type string Intel Tolapai PROPERTY PROPERTY name sc cpu speed type sint32 ...

Страница 371: ...tring 0 PROPERTY PROPERTY name health reason type string PROPERTY PROPERTY name health recommendation type string PROPERTY PROPERTY name position type string Top PROPERTY PROPERTY name position numeric type string 1 PROPERTY PROPERTY name phy isolation type string Enabled PROPERTY PROPERTY name phy isolation numeric type string 0 PROPERTY PROPERTY name redundancy mode type string Unknown PROPERTY ...

Страница 372: ...r of times the block to be read is found in cache read cache misses uint64 For the controller that owns the volume the number of times the block to be read is not found in cache number of writes uint64 For the controller whose host ports had I O activity the number of write operations since these statistics were last reset or since the controller was restarted write cache hits uint64 For the contr...

Страница 373: ...B PROPERTY PROPERTY name data read numeric type string 100017762304 PROPERTY PROPERTY name data written units GB type string 11 80GB PROPERTY PROPERTY name data written numeric type string 11807576064 PROPERTY PROPERTY name reset time type string 2012 02 13 12 45 35 PROPERTY PROPERTY name reset time numeric type string 1329137135 PROPERTY PROPERTY name start sample time type string 2012 02 24 12 4...

Страница 374: ...sion in the Storage Controller debug log Off Disabled This is the default On Enabled mem numeric string Numeric equivalents for mem values 0 Off 1 On fo string Shows whether failover and recovery debug messages are enabled for inclusion in the Storage Controller debug log Off Disabled On Enabled This is the default fo numeric string Numeric equivalents for fo values 0 Off 1 On msg string Shows whe...

Страница 375: ...age Controller debug log Off Disabled This is the default On Enabled iod numeric string Numeric equivalents for iod values 0 Off 1 On misc string Shows whether internal debug messages are enabled for inclusion in the Storage Controller debug log Off Disabled On Enabled This is the default misc numeric string Numeric equivalents for misc values 0 Off 1 On rcm string Shows whether removable componen...

Страница 376: ...lt capi numeric string Numeric equivalents for capi values 0 Off 1 On mui string Shows whether internal service interface debug messages are enabled for inclusion in the Storage Controller debug log Off Disabled On Enabled This is the default mui numeric string Numeric equivalents for mui values 0 Off 1 On bkcfg string Shows whether internal configuration debug messages are enabled for inclusion i...

Страница 377: ...age Controller debug log Off Disabled On Enabled This is the default dms numeric string Numeric equivalents for dms values 0 Off 1 On fruid string Shows whether FRU ID debug messages are enabled for inclusion in the Storage Controller debug log Off Disabled On Enabled This is the default fruid numeric string Numeric equivalents for fruid values 0 Off 1 On resmgr string Shows whether Reservation Ma...

Страница 378: ...e string On PROPERTY PROPERTY name raid numeric type string 1 PROPERTY PROPERTY name cache type string On PROPERTY PROPERTY name cache numeric type string 1 PROPERTY PROPERTY name emp type string On PROPERTY PROPERTY name emp numeric type string 1 PROPERTY PROPERTY name capi type string On PROPERTY PROPERTY name capi numeric type string 1 PROPERTY PROPERTY name mui type string On PROPERTY PROPERTY...

Страница 379: ...g time write iops uint64 Number of write operations per second since the last sampling time total bytes per second string Total data transfer rate in bytes per second since the last sampling time total bytes per second numeric uint64 Unformatted total bytes per second value read bytes per second string Data transfer rate in bytes per second for read operations since the last sampling time read byt...

Страница 380: ...uint64 9890 PROPERTY PROPERTY name avg io size units KB type string 82 94KB PROPERTY PROPERTY name avg io size numeric type string 82944 PROPERTY PROPERTY name avg read io size units KB type string 49 15KB PROPERTY PROPERTY name avg read io size numeric type string 49152 PROPERTY PROPERTY name avg write io size units KB type string 91 13KB PROPERTY PROPERTY name avg write io size numeric type stri...

Страница 381: ...HP P2000 G3 MSA System CLI Reference Guide 381 PROPERTY name sample time type string 2012 02 15 10 30 00 PROPERTY PROPERTY name sample time numeric type string 1329301800 PROPERTY OBJECT ...

Страница 382: ...ta read numeric string Unformatted data read value data written string Amount of data written since these statistics were last reset or since the controller was restarted data written numeric string Unformatted data written value queue depth uint32 Number of pending I O operations currently being serviced reset time string Date and time in the format year month day hour minutes seconds when these ...

Страница 383: ...o timeout count 1 type uint32 0 PROPERTY PROPERTY name no response count 1 type uint32 0 PROPERTY PROPERTY name spinup retry count 1 type uint32 0 PROPERTY number of media errors 1 uint32 For port 1 the number of media errors generated by the disk as specified by its manufacturer number of nonmedia errors 1 uint32 For port 1 the number of other errors generated by the storage system or generated b...

Страница 384: ...TY PROPERTY name smart count 2 type uint32 0 PROPERTY PROPERTY name io timeout count 2 type uint32 0 PROPERTY PROPERTY name no response count 2 type uint32 0 PROPERTY PROPERTY name spinup retry count 2 type uint32 0 PROPERTY PROPERTY name number of media errors 2 type uint32 0 PROPERTY PROPERTY name number of nonmedia errors 2 type uint32 1 PROPERTY PROPERTY name number of block reassigns 2 type u...

Страница 385: ...ite back cache numeric string Numeric equivalents for drive write back cache values 0 Detect Only 1 Enabled 2 Disabled drive timeout retry max uint8 Maximum number of times a timed out I O operation can be retried before the operation is failed The default is 3 drive attempt timeout uint8 Number of seconds before an I O operation is aborted and possibly retried The default is 8 seconds drive overa...

Страница 386: ...t type uint8 105 PROPERTY PROPERTY name disk dsd enable type string Disabled PROPERTY PROPERTY name disk dsd enable numeric type string 0 PROPERTY PROPERTY name disk dsd enable pool type string Disabled PROPERTY PROPERTY name disk dsd enable pool numeric type string 0 PROPERTY PROPERTY name disk dsd delay type uint16 0 PROPERTY PROPERTY name disk dsd delay pool type uint16 0 PROPERTY OBJECT disk d...

Страница 387: ...rive oid 1 format rows PROPERTY name durable id type string disk_1 1 PROPERTY PROPERTY name serial number key true type string SN PROPERTY OBJECT Embedded basetypes disk hist statistics Table 25 drive summary properties Name Type Description durable id string Disk ID in the form disk_enclosure number disk number serial number string Disk serial number ...

Страница 388: ...he disk is available FAILED The disk is unusable and must be replaced Reasons for this status include excessive media errors SMART error disk hardware failure unsupported disk GLOBAL SP The disk is a global spare LEFTOVR The disk is a leftover and can be reused after its metadata is cleared VDISK The disk is used in a vdisk VDISK SP The disk is a spare assigned to a vdisk secondary channel uint32 ...

Страница 389: ...used smart string Disabled SMART is disabled for this disk Enabled SMART is enabled for this disk smart numeric string Numeric equivalents for smart values 0 Disabled 1 Enabled dual port uint32 0 Single ported disk 1 Dual ported disk error uint32 Not used fc p1 channel uint32 Port 1 channel ID fc p1 device id uint32 Port 1 device ID fc p1 node wwn string Port 1 WWNN fc p1 port wwn string Port 1 WW...

Страница 390: ...s until the controller is restarted or power cycled transfer rate numeric string For internal use only attributes string Shows which controller a single ported disk is connected to A Controller A B Controller B attributes numeric string For internal use only virtual disk serial string Serial number of the disk s vdisk if any enclosure wwn string Enclosure WWN status string Disk status Up The disk ...

Страница 391: ...ult Pred Fail The disk has a predictive failure ID The locator LED is illuminated to identify the disk led status numeric string Numeric equivalents for led status values 1 Online 2 Rebuild 4 Fault 8 Pred Fail 16 ID disk dsd count uint32 Number of times the DSD feature has spun down this disk number of ios uint64 Total I Os total data transferred bytes Total bytes transferred total data transferre...

Страница 392: ... PROPERTY PROPERTY name fc p2 port wwn type string PROPERTY PROPERTY name fc p2 unit number type uint32 0 PROPERTY PROPERTY name drive down code type uint8 0 PROPERTY PROPERTY name owner type string A PROPERTY PROPERTY name owner numeric type string 1 PROPERTY PROPERTY name index type uint32 0 PROPERTY PROPERTY name rpm units K type uint32 7 PROPERTY PROPERTY name size units GB type string 500 10G...

Страница 393: ...ng Numeric equivalents for email notification filter values 8 crit 4 error 2 warn 1 info 0 none email notify address 1 string Up to three email addresses for recipients of event notifications Blank by default email notify address 2 string email notify address 3 string email notify address 4 string Shows the email address for the log collection system used by the log management feature Blank by def...

Страница 394: ... string 12 PROPERTY PROPERTY name email notify address 1 type string admin mycompany com PROPERTY PROPERTY name email notify address 2 type string PROPERTY PROPERTY name email notify address 3 type string PROPERTY PROPERTY name email notify address 4 type string PROPERTY PROPERTY name email server type string 10 64 10 105 PROPERTY PROPERTY name email domain type string mycompany com PROPERTY PROPE...

Страница 395: ...re sensor Voltage Voltage sensor Disk Disk drive module enclosure unit number string Component ID status string Component status Absent The component is not present Error The component or at least one subcomponent has failed Warning The component or at least one subcomponent is not working normally OK The component and any subcomponents are working normally Temperature status OK indicates that the...

Страница 396: ...RU was manufactured mfg vendor id string JEDEC ID of the FRU manufacturer fru location string Location of the FRU in the enclosure MID PLANE SLOT Chassis midplane UPPER IOM SLOT Controller module or expansion module A LOWER IOM SLOT Controller module or expansion module B LEFT PSU SLOT Power supply module on the left as viewed from the back RIGHT PSU SLOT Power supply module on the right as viewed...

Страница 397: ... fru shortname type string Midplane Chassis PROPERTY PROPERTY name mfg date type string 2011 11 01 22 14 57 PROPERTY PROPERTY name mfg date numeric type string 1320185697 PROPERTY PROPERTY name mfg location type string Longmont CO USA PROPERTY PROPERTY name mfg vendor id key true type string 0x03FD PROPERTY PROPERTY name fru location type string MID PLANE SLOT PROPERTY PROPERTY name configuration ...

Страница 398: ...rly communicating with the expander Spun Down The disk is present and has been spun down by the drive spin down feature Warning The disk is present but the system is having communication problems with the disk LED processor For disk and midplane types where this processor also controls power to the disk power on failure will result in Error status Error The disk is present but is not detected by t...

Страница 399: ...units in the enclosure number of disks uint8 Number of disk slots not installed disks in the enclosure number of power supplies uint8 Number of power supplies in the enclosure status string Disk slot status Unsupported Up Error Warning Unrecoverable Not Present Unknown Unavailable Spun Down status numeric string Numeric equivalents for status values 0 Unsupported 1 Up 2 Error 3 Warning 4 Unrecover...

Страница 400: ...s are oriented horizontally drive orientation numeric string Numeric equivalents for drive orientation values 0 vertical 1 horizontal enclosure arrangement string vertical Disks are numbered vertically by column from top to bottom proceeding rightward horizontal Disks are numbered horizontally by row from left to right proceeding downward enclosure arrangement numeric string Numeric equivalents fo...

Страница 401: ...for 2U reduced depth 12 disk enclosure with 6 Gbps maximum data rate to disks 2U12 6G Midplane for 2U 12 disk enclosure with 6 Gbps maximum data rate to disks 2U12 3G Midplane for 2U 12 disk enclosure with 3 Gbps maximum data rate to disks N A Other type of midplane midplane type numeric string Numeric equivalents for midplane type values 0 2U12 3G 1 2U24 3G 2 2U12 6G 3 2U24 6G 5 9 13 2U24 6Gv2 6 ...

Страница 402: ...OPERTY name columns type uint8 24 PROPERTY PROPERTY name slots type uint8 24 PROPERTY PROPERTY name drive orientation type string vertical PROPERTY PROPERTY name drive orientation numeric type string 0 PROPERTY PROPERTY name enclosure arrangement type string vertical PROPERTY PROPERTY name enclosure arrangement numeric type string 0 PROPERTY PROPERTY name emp a busid type string 00 PROPERTY PROPER...

Страница 403: ...RTY name sku partnumber type string AW568A PROPERTY PROPERTY name sku_serialnumber type string 3CL013C014 PROPERTY PROPERTY name sku revision type string F PROPERTY OBJECT Table 32 enclosure sku properties Name Type Description sku partnumber string System part number sku_serialnumber string System serial number sku revision string System revision level ...

Страница 404: ...r string Controller serial number controller string A Controller A B Controller B controller numeric string Numeric equivalents for controller values 0 B 1 A severity string Event severity CRITICAL A failure occurred that may cause a controller to shut down Correct the problem immediately ERROR A failure occurred that may affect data integrity or system stability Correct the problem as soon as pos...

Страница 405: ...ty numeric type string 0 PROPERTY PROPERTY name message type string A rescan bus operation was done number of disks that were found 45 number of enclosures that were found 4 rescan reason initiated by a user rescan reason code 0 PROPERTY PROPERTY name additional information type string None PROPERTY PROPERTY name recommended action type string No action is required PROPERTY OBJECT ...

Страница 406: ...expansion module Can be connected to an egress expansion port on a controller module or an expansion module name numeric string 2 In Port 3 Out Port status string Expander port status Up Warning Error Not Present Unknown Disconnected status numeric string Numeric equivalents for status values 0 Up 1 Warning 2 Error 3 Not Present 4 Unknown 6 Disconnected health string OK Degraded Fault N A Unknown ...

Страница 407: ...ler type string A PROPERTY PROPERTY name controller numeric type string 1 PROPERTY PROPERTY name name type string Out Port PROPERTY PROPERTY name name numeric type string 3 PROPERTY PROPERTY name status type string Up PROPERTY PROPERTY name status numeric type string 0 PROPERTY PROPERTY name health type string OK PROPERTY PROPERTY name health numeric type string 0 PROPERTY PROPERTY name health rea...

Страница 408: ...enclosure status string Fan unit status Up Warning Error Not Present Unknown status numeric string Numeric equivalents for status values 0 Up 1 Warning 2 Error 3 Not Present 4 Unknown speed uint32 Fan speed RPM position string Fan position as viewed from the back of the enclosure Left Right Top Bottom position numeric string Numeric equivalents for position values 0 Left 1 Right 2 Top 3 Bottom ser...

Страница 409: ...eric type string 0 PROPERTY PROPERTY name serial number type string PROPERTY PROPERTY name fw revision type string PROPERTY PROPERTY name hw revision type string PROPERTY PROPERTY name health type string OK PROPERTY PROPERTY name health numeric type string 0 PROPERTY PROPERTY name health reason type string PROPERTY PROPERTY name health recommendation type string PROPERTY OBJECT health numeric stri...

Страница 410: ...ary loop id type string 0 PROPERTY OBJECT Table 36 fc port properties Name Type Description configured topology string Configured topology Loop Fibre Channel arbitrated loop public or private Point to Point Fibre Channel point to point Auto Loop preferred otherwise point to point based on the detected connection type This is the default primary loop id string Primary loop ID 0 125 or blank if not ...

Страница 411: ...en since these statistics were last reset or since the controller was restarted data written numeric string Unformatted data written value queue depth uint32 The number of pending I O operations currently being serviced avg rsp time string Average response time in microseconds for read and write operations calculated over the interval since these statistics were last requested or reset avg read rs...

Страница 412: ...g 17821696 PROPERTY PROPERTY name data written units GB type string 11 80GB PROPERTY PROPERTY name data written numeric type string 11807576064 PROPERTY PROPERTY name queue depth type uint32 0 PROPERTY PROPERTY name avg rsp time type uint32 227607 PROPERTY PROPERTY name avg read rsp time type uint32 3583 PROPERTY PROPERTY name avg write rsp time type uint32 238221 PROPERTY PROPERTY name reset time...

Страница 413: ...rt WWN or iSCSI host initiator node name typically the IQN host name string User defined name of the host port or blank host discovered string Yes The host was discovered and its entry was automatically created No The host entry was manually created host mapped string Yes At least one volume is explicitly mapped to the host No No volumes are explicitly mapped to the host host profile string Standa...

Страница 414: ...d PROPERTY OBJECT Embedded basetypes host view mappings Table 39 host view properties Name Type Description id string FC or SAS host port WWN or iSCSI host initiator node name typically the IQN hba nickname string User defined name of the host port or blank host profile string Standard The host allows LUN 0 to be assigned to a mapping This is the default OpenVMS The host does not allow LUN 0 to be...

Страница 415: ...me access type string read write PROPERTY PROPERTY name ports type string A1 A2 B1 B2 PROPERTY OBJECT Table 40 host view mappings properties Name Type Description volume name string Volume name volume serial string Volume serial number lun string LUN assigned to the mapping access string Type of access assigned to the mapping read write Host has read and write access to the volume read only Host h...

Страница 416: ...type string 00 C0 FF DA F1 00 PROPERTY PROPERTY name ip address type string 10 136 140 106 PROPERTY PROPERTY name nvram defaults type string PROPERTY OBJECT Table 41 inquiry properties Name Type Description mc fw string Management Controller firmware version mc loader string Management Controller loader firmware version sc fw string Storage Controller firmware version sc loader string Storage Cont...

Страница 417: ...roller s PCBA was programmed or a power supply module was manufactured mfg date numeric string Unformatted mfg date value mfg location string City state province and country where the FRU was manufactured mfg vendor id string JEDEC ID of the FRU manufacturer position string Fan unit position as viewed from the back of the enclosure Top Bottom Left Right position numeric string Numeric equivalents ...

Страница 418: ...ing PROPERTY PROPERTY name position type string Top PROPERTY PROPERTY name position numeric type string 0 PROPERTY PROPERTY name configuration serialnumber type string PROPERTY PROPERTY name phy isolation type string Enabled PROPERTY PROPERTY name phy isolation numeric type string 0 PROPERTY PROPERTY name status type string Up PROPERTY PROPERTY name status numeric type string 0 PROPERTY PROPERTY n...

Страница 419: ...LI Reference Guide 419 PROPERTY name health numeric type string 0 PROPERTY PROPERTY name health reason type string PROPERTY PROPERTY name health recommendation type string PROPERTY OBJECT Embedded basetypes unhealthy component ...

Страница 420: ...ed Jumbo frame support is enabled Disabled Jumbo frame support is disabled This is the default jumbo frames numeric string Numeric equivalents for jumbo frames values 0 Disabled 1 Enabled isns string Shows whether support for Internet Storage Name Service iSNS is enabled Enabled iSNS is enabled Disabled iSNS is disabled This is the default isns numeric string Numeric equivalents for isns values 0 ...

Страница 421: ...e Guide 421 PROPERTY name isns alt ip type string 0 0 0 0 PROPERTY PROPERTY name iscsi speed type string 1Gbps PROPERTY PROPERTY name iscsi speed numeric type string 1 PROPERTY PROPERTY name iscsi ip version type uint8 4 PROPERTY OBJECT ...

Страница 422: ...ROPERTY PROPERTY name secondary mac address type string PROPERTY OBJECT Table 44 iscsi port properties Name Type Description ip version string iSCSI IP version IPv4 iSCSI host port addresses use IPv4 format This is the default IPv6 iSCSI host port addresses use IPv6 format primary ip address string Primary IP address primary gateway string Primary gateway IP address primary netmask string Primary ...

Страница 423: ...abled background scrub pool string Not applicable background scrub pool numeric string Not applicable partner firmware upgrade string Shows whether component firmware versions are monitored and will be automatically updated on the partner controller Disabled Partner firmware upgrade is disabled Enabled Partner firmware upgrade is enabled This is the default partner firmware upgrade numeric string ...

Страница 424: ...424 XML API basetype properties PROPERTY name utility priority numeric type string 0 PROPERTY OBJECT ...

Страница 425: ...s expiry values 0 Never 255 Expired days Number of days remaining volume copy string Shows whether the Volume Copy feature is enabled Disabled Volume Copy is disabled Enabled Volume Copy is enabled volume copy numeric string Numeric equivalents for volume copy values 0 Disabled 1 Enabled volume copy expiry string Shows when the Volume Copy license will expire Never Always enabled and doesn t expir...

Страница 426: ...enabled vss numeric string Numeric equivalents for vss values 0 Disabled 1 Enabled vss expiry string Shows when the VSS Volume Shadow Copy Service Hardware Provider will expire Never Always enabled and doesn t expire vss expiry numeric string Numeric equivalents for vss expiry values 0 Never dsd string Shows whether the Drive Spin Down DSD feature is enabled Disabled DSD is disabled Enabled DSD is...

Страница 427: ... string Never PROPERTY PROPERTY name remote snapshot replication expiry numeric type string 0 PROPERTY PROPERTY name vds type string Enabled PROPERTY PROPERTY name vds numeric type string 1 PROPERTY PROPERTY name vds expiry type string Never PROPERTY PROPERTY name vds expiry numeric type string 0 PROPERTY PROPERTY name vss type string Enabled PROPERTY PROPERTY name vss numeric type string 1 PROPER...

Страница 428: ...ROPERTY name log timestamp numeric type string 1297413501 PROPERTY OBJECT Table 47 log header table properties Name Type Description log contact string Contact person s name if specified in the SMU Save Logs panel log email string Contact s email address if specified in the SMU Save Logs panel log phone string Contact s phone number if specified in the SMU Save Logs panel log comments string Comme...

Страница 429: ...ring Master volume serial number name string Master volume name size string Master volume size formatted to use the current base precision and units size numeric string Unformatted size value in 512 byte blocks status string Master volume status Available The master volume is available Unavailable The master volume is not available status reason string More information about the status value MV No...

Страница 430: ...string Numeric equivalents for link speed values 0 10mbps 1 100mbps 2 Unknown duplex mode string Undefined Either the duplex mode has not been set or it has been unset because the controller module was removed from its enclosure Half The network port duplex mode is set to half duplex Full The network port duplex mode is set to full duplex duplex mode numeric string Numeric equivalents for duplex m...

Страница 431: ...ic type string 0 PROPERTY PROPERTY name auto negotiation type string Enabled PROPERTY PROPERTY name auto negotiation numeric type string 1 PROPERTY PROPERTY name health type string OK PROPERTY PROPERTY name health numeric type string 0 PROPERTY PROPERTY name health reason type string PROPERTY PROPERTY name health recommendation type string PROPERTY PROPERTY name ping broadcast type string Disabled...

Страница 432: ...ype string 2012 02 15 14 52 16 PROPERTY OBJECT Table 50 ntp status properties Name Type Description ntp status string Shows whether use of Network Time Protocol NTP is enabled activated NTP is enabled deactivated NTP is disabled This is the default ntp server address string 0 0 0 0 NTP server IP address is not set NTP server IP address ntp contact time string Date and time in the format year month...

Страница 433: ...ggers the threshold s policy policy string Recovery policy to invoke when threshold value is reached autoexpand Try to expand the snap pool by the size to expand value If the snap pool s space usage reaches the percentage specified by its error threshold the system will log Warning event 230 and will try to expand the snap pool by the snap pool s size to expand value below If the snap pool is succ...

Страница 434: ...FC Fibre Channel iSCSI Internet SCSI SAS Serial Attached SCSI port type numeric string Numeric equivalents for port type values 6 FC 8 SAS 9 iSCSI media string FC P Fibre Channel Point to Point public or private FC L Fibre Channel Arbitrated Loop FC Not applicable as when the port is disconnected SAS Serial Attached SCSI iSCSI Internet SCSI target id string Port WWN or IQN status string Port statu...

Страница 435: ...b 2 4Gb 4 1 5Gb 5 3Gb 6 6Gb 7 8Gb 8 10Mb 9 100Mb 10 10Gb 255 Port is disconnected configured speed string Configured port speed in Gbit sec Auto the default 1Gb 2Gb 4Gb 8Gb configured speed numeric string Numeric equivalents for configured speed values 0 1Gb 1 2Gb 2 4Gb 3 Auto 7 8Gb health string OK Degraded Fault N A health numeric string Numeric equivalents for health values 0 OK 1 Degraded 2 Fa...

Страница 436: ...OPERTY PROPERTY name status numeric type string 0 PROPERTY PROPERTY name actual speed type string 4Gb PROPERTY PROPERTY name actual speed numeric type string 2 PROPERTY PROPERTY name configured speed type string Auto PROPERTY PROPERTY name configured speed numeric type string 3 PROPERTY PROPERTY name health type string OK PROPERTY PROPERTY name health numeric type string 0 PROPERTY PROPERTY name h...

Страница 437: ...sition numeric string Numeric equivalents for position values 0 Left 1 Right 2 Top 3 Bottom part number string FRU part number dash level string FRU template revision number fru shortname string FRU short description mfg date string Date and time in the format year month day hour minutes seconds UTC when the power supply module was manufactured mfg date numeric string Unformatted mfg date value mf...

Страница 438: ... 01 18 22 38 18 PROPERTY PROPERTY name mfg date numeric type string 1169159898 PROPERTY PROPERTY name mfg location type string Milpitas CA US PROPERTY PROPERTY name mfg vendor id key true type string 0x0301 PROPERTY PROPERTY name configuration serialnumber type string SN PROPERTY PROPERTY name dc12v type uint32 1249 PROPERTY PROPERTY name dc5v type uint32 551 PROPERTY PROPERTY name dc33v type uint...

Страница 439: ...RTY name health numeric type string 0 PROPERTY PROPERTY name health reason type string PROPERTY PROPERTY name health recommendation type string PROPERTY PROPERTY name status type string Up PROPERTY PROPERTY name status numeric type string 0 PROPERTY OBJECT Embedded basetypes unhealthy component fan ...

Страница 440: ...d the other is offline In single controller mode the controller is operational Down This controller is not operational Unknown Status information is not available redundancy status numeric string Numeric equivalents for redundancy status values 1 Redundant 3 Operational but not redundant 4 Down 5 Unknown controller a status string Operational The controller is operational Down The controller is in...

Страница 441: ...status type string Redundant PROPERTY PROPERTY name redundancy status numeric type string 5918 PROPERTY PROPERTY name controller a status type string Operational PROPERTY PROPERTY name controller a status numeric type string 0 PROPERTY PROPERTY name controller a serial number type string SN PROPERTY PROPERTY name controller b status type string Operational PROPERTY PROPERTY name controller b statu...

Страница 442: ...RTY name disk hist statistics 0 PROPERTY PROPERTY name virtual disk summary 0 PROPERTY OBJECT Table 55 refresh counters properties Name Type Description basetype name Not shown Shows when the data represented by the base type was last updated 0 The data has never been updated and is not cached nonzero number A timestamp indicating that the data has been updated If the value has changed since the l...

Страница 443: ... 56 remote addresses properties Name Type Description connected ports string port IDs For a remote primary or secondary volume the IDs of up to two hosts ports in the local system that are connected to the remote system If two ports are connected but only one is shown this indicates that a problem is preventing half the available bandwidth from being used N A For a local primary or secondary volum...

Страница 444: ...ws PROPERTY name local host port type string A1 PROPERTY PROPERTY name type type string FC PROPERTY PROPERTY name type numeric type string 6 PROPERTY PROPERTY name remote links type string B0 B1 PROPERTY OBJECT Table 57 remote links properties Name Type Description local host port string Controller host port ID in the local system in the form hostport_controller ID and port number type string FC F...

Страница 445: ...of the network port in controller B in the remote system Not Present username string Name of a user that is configured in the remote system This must be a manage level user to remotely configure or provision that system status string Uninitialized This system hasn t communicated with the remote system Ready This system has contacted the remote system and it is ready to use Connected This system is...

Страница 446: ...ername type string manage PROPERTY PROPERTY name status type string Connected PROPERTY PROPERTY name status numeric type string 2 PROPERTY PROPERTY name last connected type string 2012 02 16 10 37 55 PROPERTY PROPERTY name interfaces type string iSCSI PROPERTY PROPERTY name interfaces numeric type string 3 PROPERTY PROPERTY name isvalid ip a type string True PROPERTY PROPERTY name isvalid ip a num...

Страница 447: ...licate volume tasks properties Name Type Description primary volume name string Primary volume name primary volume serial string Primary volume serial number snapshot prefix string A label to identify snapshots created by this task Snapshot names have the format prefix_s where starts at 001 replication mode string new snapshot Replicate a new snapshot of the volume to the remote system This is the...

Страница 448: ...1 PROPERTY OBJECT Embedded basetypes replication image params Table 60 replication image properties Name Type Description image key string Replication image ID replication volume serial number string Replication volume serial number image serial number string Replication image serial number replication image source string Name of the source replication image snapshot serial string Replication snap...

Страница 449: ...s string Progress in percent if the image is being replicated Applies only to secondary volumes start time string Date and time in the format year month day hour minutes seconds UTC when the replication operation started start time numeric string Unformatted start time value update time string Date and time in the format year month day hour minutes seconds UTC when the replication operation status...

Страница 450: ...ype string 2012 02 16 11 02 01 PROPERTY PROPERTY name start time numeric type string 1329390121 PROPERTY PROPERTY name update time type string 2012 02 16 11 05 49 PROPERTY PROPERTY name update time numeric type string 1329390349 PROPERTY PROPERTY name suspended time type string N A PROPERTY PROPERTY name suspended time numeric type string 0 PROPERTY PROPERTY name est completion time type string N ...

Страница 451: ...et name volume oid 1 format labeled PROPERTY name name type string rsvd02_v001 PROPERTY PROPERTY name serial number key true type string SN PROPERTY OBJECT Embedded basetypes replication volume Table 62 replication set properties Name Type Description name string Replication set name serial number string Replication set serial number ...

Страница 452: ...essed but is unusable due to an error Establishing proxy The volume is establishing a proxy connection to a remote volume This will occur when a detached secondary volume is reattached and is re establishing a connection with the primary system in preparation for replication Detached The volume is detached for removal status numeric string Numeric equivalents for status values 0 Initializing 1 Onl...

Страница 453: ...ages to consider when determining the next image to replicate Used only if the collision policy property is set to Oldest The default is 32 max retry time uint32 Maximum amount of time in seconds that the replication volume should retry a replication operation on any specific image when errors occur Used only if the error policy property is set to Retry The default is 1800 error policy string Dete...

Страница 454: ...e system s processors High Replication has higher priority than host I O This can cause heavy I O to be slower than normal This is the default Medium Replication performance is balanced with host I O performance Low Replication runs at a slower rate with minimal effect on host I O Use when streaming data without interruption is more important than data redundancy priority numeric string Numeric eq...

Страница 455: ... queue type uint32 32 PROPERTY PROPERTY name max retry time type uint32 1800 PROPERTY PROPERTY name error policy type string Retry PROPERTY PROPERTY name error policy numeric type string 0 PROPERTY PROPERTY name link type type string iSCSI PROPERTY PROPERTY name link type numeric type string 128 PROPERTY PROPERTY name collision policy type string Oldest PROPERTY PROPERTY name collision policy nume...

Страница 456: ...imary Volume PROPERTY PROPERTY name volume type numeric key true type string 1 PROPERTY OBJECT Embedded basetypes replication image Table 64 replication volume summary properties Name Type Description name string Replication volume name serial number string Replication volume serial number volume type string Primary Volume The volume is the primary volume in a replication set Secondary Volume The ...

Страница 457: ... task reset snapshot oid 4 format pairs PROPERTY name snapshot name type string vd02_v001_s001 PROPERTY PROPERTY name snapshot serial type string SN PROPERTY OBJECT Table 65 reset snapshot tasks properties Name Type Description snapshot name string Name of the snapshot to reset snapshot serial string Serial number of the snapshot to reset ...

Страница 458: ...as port name port details oid 2 format rows PROPERTY name configured topology type string Direct PROPERTY PROPERTY name width type string 4 PROPERTY OBJECT Table 66 sas port properties Name Type Description configured topology string Direct width string Number of PHY lanes in the SAS port ...

Страница 459: ...t Egress 4 lane PHY that communicates between the expander and an expansion port or SAS Out port Inter Exp Expansion module only Communicates between the expander and the partner s expander SC 0 Controller module only 4 lane PHY that communicates between the expander and the SC SC 1 Controller module only 2 lane PHY that communicates between the expander and the partner s expander Unused The PHY e...

Страница 460: ...itical 4 Error 5 Not Used 6 Unknown 7 Unknown 8 Unknown elem disabled string Enabled PHY is enabled Disabled PHY is disabled elem disabled numeric string Numeric equivalents for elem disabled values 0 Enabled 1 Disabled elem reason string More information about the status value Blank if elem status is OK Error count interrupts PHY disabled because of error count interrupts Externally disabled PHY ...

Страница 461: ...74 Drive removed 32775 Unused disabled by default 32776 Excessive PHY changes change counter uint32 Number of times the PHY originated a BROADCAST CHANGE A BROADCAST CHANGE is sent if doubleword synchronization is lost or at the end of a Link Reset sequence code violations uint32 Number of times the PHY received an unrecognized or unexpected signal disparity errors uint32 Number of doublewords con...

Страница 462: ...e uint32 00000000 PROPERTY PROPERTY name lost dwords type uint32 00000000 PROPERTY PROPERTY name invalid dwords type uint32 00000000 PROPERTY PROPERTY name reset error counter type uint32 00000000 PROPERTY PROPERTY name flag bits type uint32 4001a025 PROPERTY OBJECT ...

Страница 463: ...ng PROPERTY OBJECT See also tasks Table 68 schedules properties Name Type Description name string Schedule name schedule specification string Schedule settings for running the associated task status string Schedule status Uninitialized The schedule is not yet ready to run Ready The schedule is ready to run at the next scheduled time Suspended The schedule had an error and is holding in its current...

Страница 464: ...led cli ssh string Disabled The secure shell CLI is disabled Enabled The secure shell CLI is enabled This is the default cli ssh numeric string Numeric equivalents for cli ssh values 0 Disabled 1 Enabled smis string Disabled The secure SMI S interface is disabled Enabled The secure SMI S interface is enabled This is the default smis numeric string Numeric equivalents for smis values 0 Disabled 1 E...

Страница 465: ...e string 0 PROPERTY PROPERTY name ftp type string Enabled PROPERTY PROPERTY name ftp numeric type string 1 PROPERTY PROPERTY name snmp type string Enabled PROPERTY PROPERTY name snmp numeric type string 1 PROPERTY PROPERTY name debug interface type string Enabled PROPERTY PROPERTY name debug interface numeric type string 1 PROPERTY PROPERTY name inband ses type string Enabled PROPERTY PROPERTY nam...

Страница 466: ...r condition Temperature voltage or current exceeds the critical threshold Unavailable The sensor is present with no known errors but has not been turned on or set into operation because it is initializing This typically occurs during controller startup Unrecoverable The enclosure management processor EMP cannot communicate with the sensor Unknown The sensor is present but status is not available N...

Страница 467: ...ROPERTY name enclosure id type uint32 1 PROPERTY PROPERTY name sensor name key true type string On Board Temperature 1 Ctlr A PROPERTY PROPERTY name value type string 45 C PROPERTY PROPERTY name status type string OK PROPERTY PROPERTY name status numeric type uint32 3 PROPERTY PROPERTY name sensor location type uint32 8 PROPERTY PROPERTY name sensor type type uint32 3 PROPERTY OBJECT ...

Страница 468: ...ble 71 ses properties Name Type Description id string SCSI ID of the enclosure chassis string Chassis serial number vendor string Enclosure vendor name product id string Product model identifier cpld revision string Complex Programmable Logic Device version emp a busid string SCSI channel ID of controller A s EMP emp a targetid string SCSI target ID of controller A s EMP emp a rev string Firmware ...

Страница 469: ...HP P2000 G3 MSA System CLI Reference Guide 469 PROPERTY name status type string OK PROPERTY OBJECT ...

Страница 470: ...name controller oid 1 format packed PROPERTY name controller type string A PROPERTY PROPERTY name status type string up PROPERTY OBJECT Table 72 shutdown status properties Name Type Description controller string A Controller A B Controller B status string up The controller is operational down The controller is shut down ...

Страница 471: ...old Table 73 snap pools properties Name Type Description virtual disk name string Vdisk name serial number string Snap pool serial number name string Snap pool name size string Snap pool size formatted to use the current base precision and units size numeric string Unformatted size value in 512 byte blocks free string Amount of free space in this snap pool formatted to use the current base precisi...

Страница 472: ...ound Snapshot pending not yet committed Snap pool not accessible Master volume not accessible Volume copy with modified data is in progress Rollback with modified data is in progress status reason numeric string Numeric equivalents for status reason values 1 Snapshot pending not yet committed 3 Snap pool not accessible 4 Master volume not accessible 6 Rollback with modified data is in progress 7 V...

Страница 473: ...apshot DRM A temporary standard snapshot created from a replication snapshot for the purpose of doing a test failover for disaster recovery management DRM Replication snapshot For a primary or secondary volume a snapshot that was created by a replication operation but is not a sync point Replication snapshot Replicating For a primary volume a snapshot that is being replicated to a secondary system...

Страница 474: ... PROPERTY PROPERTY name uniquedata units B type string 0B PROPERTY PROPERTY name uniquedata numeric units blocks512 type string 0 PROPERTY PROPERTY name shareddata units B type string 0B PROPERTY PROPERTY name shareddata numeric units blocks512 type string 0 PROPERTY PROPERTY name priority value type string 0x6000 PROPERTY PROPERTY name user_priority value type string 0x0000 PROPERTY PROPERTY name...

Страница 475: ...uint32 1 PROPERTY PROPERTY name last created type string PROPERTY OBJECT Table 75 snapshot with retention tasks properties Name Type Description master volume name string Source volume name master volume serial string Source volume serial number snapshot prefix string A label to identify snapshots created by this task Snapshot names have the format prefix_s where starts at 001 retention count uint...

Страница 476: ...sks name snapshots oid 3 format rows PROPERTY name snapshot name key true type string v1_R0003 PROPERTY PROPERTY name snapshot serial type string SN PROPERTY OBJECT Table 76 snap tasks properties Name Type Description snapshot name string Snapshot name snapshot serial string Snapshot serial number ...

Страница 477: ...gement Protocol SNMP interface is enabled or disabled Disabled SNMP is disabled This is the default Enabled SNMP is enabled snmp enabled numeric string Numeric equivalents for snmp enabled values 0 Disabled 1 Enabled snmp filter string Minimum level of events to include for SNMP traps crit Only critical events are sent as traps error Error and critical events are sent as traps warn Warning error a...

Страница 478: ...TY name time stamp numeric type string 1329400001 PROPERTY OBJECT Table 78 status properties Name Type Description response type string Success The command succeeded Error The command failed Info The command returned an informational message response type numeric string 0 Success 1 Error 2 Info response string A message stating what the command accomplished why the command failed or information ab...

Страница 479: ...t is Uninitialized Name system contact string The name of person who administers the system The default is Uninitialized Contact system location string The location of the system The default is Uninitialized Location system information string A brief description of what the system is used for or how it s configured The default is Uninitialized Info midplane serial number string The serial number o...

Страница 480: ...ROPERTY name health reason type string PROPERTY PROPERTY name supported locales type string locales PROPERTY PROPERTY name current node wwn type string 208000c0ff143286 PROPERTY OBJECT Embedded basetypes redundancy unhealthy component ...

Страница 481: ...rts uint32 Number of host interface ports in the controller enclosure max drives uint32 Number of disks that the system supports max volumes uint32 Number of volumes that the system supports max vdisks uint32 Number of vdisks that the system supports max luns uint32 Number of LUNs that the system supports max owned arrays per controller uint32 Number of vdisks that each controller supports max sto...

Страница 482: ...lan heartbeat numeric string Not used ip address mode string CAPI_TWO_IP_ADDRESSES_MODE Dual controller system has a unique IP address for each controller CAPI_ONE_IP_ADDRESS_MODE Dual controller system has the same IP address for both controllers only one active at a time ip address mode numeric string Numeric equivalents for lan heartbeat values 0 CAPI_TWO_IP_ADDRESSES_MODE 1 CAPI_ONE_IP_ADDRESS...

Страница 483: ...ame max snapshots per snapshot group type uint32 0 PROPERTY PROPERTY name max midline per storage pool type uint32 0 PROPERTY PROPERTY name max standard per storage pool type uint32 0 PROPERTY PROPERTY name max performance per storage pool type uint32 0 PROPERTY PROPERTY name local controller type string B PROPERTY PROPERTY name local controller numeric type string 0 PROPERTY PROPERTY name serial ...

Страница 484: ... yet ready to run Ready Task is ready to run Active Task is running Error Task has an error Invalid Task is invalid state string Current step of the task For a TakeSnapshot task Start VerifyVolume ValidateLicensingLimit CreateName CreateSnap VerifySnap InspectRetention FindOldestSnap UnmapSnap ResetSnap RenameSnap For a ResetSnapshot task Start VerifySnap UnmapSnap ResetSnap For a VolumeCopy task ...

Страница 485: ...e string PROPERTY PROPERTY name associated vdisk serial type string SN PROPERTY OBJECT Embedded basetypes replicate volume tasks reset snapshot tasks snap tasks snapshot with retention tasks volume copy tasks For a ReplicateVolume task Start VerifyVolume CreateName RepVolume VerifySnap For an EnableDSD or DisableDSD task Start error message string Message if an error occurred while processing the ...

Страница 486: ...address type string 10 64 10 1 PROPERTY OBJECT Table 82 time settings table properties Name Type Description date time string Date and time in the format year month day hour minutes seconds UTC reported by the controller being accessed date time numeric string Unformatted date time value time zone offset string The system s time zone as an offset in hours and minutes from UTC This is shown only if...

Страница 487: ...equivalents for component type values 0 super cap 1 MC 2 port 3 controller 4 expansion module 5 PSU 6 disk 7 enclosure 8 vdisk component id string Component identifier such as A for controller A basetype string Component basetype primary key string Durable ID of the component health string Component health OK Degraded Fault Unknown N A health numeric string Numeric equivalents for health values 0 ...

Страница 488: ...t PROPERTY PROPERTY name basetype type string mgmt port PROPERTY PROPERTY name primary key key true type string mgmtport_a PROPERTY PROPERTY name health type string Degraded PROPERTY PROPERTY name health numeric type string 1 PROPERTY PROPERTY name health reason type string The network port Ethernet cable is unplugged or the network is inoperable PROPERTY PROPERTY name health recommendation type s...

Страница 489: ...PERTY name unwritable a percentage type uint8 0 PROPERTY PROPERTY name unwritable b percentage type uint8 0 PROPERTY OBJECT Table 84 unwritable cache properties Name Type Description unwritable a percentage uint8 Total percentage of cache memory used for unwritable data in controller A unwritable b percentage uint8 Total percentage of cache memory used for unwritable data in controller B ...

Страница 490: ...lank User cannot access this interface interface access CLI string x User can use the command line interface blank User cannot access this interface This is the default interface access FTP string x User can use the file transfer protocol interface blank User cannot access this interface This is the default interface access SMIS string x User can use the Storage Management Initiative Specification...

Страница 491: ...ale numeric string Numeric equivalents for temperature scale values 0 Fahrenheit 1 Celsius timeout uint32 Time in seconds that the session can be idle before it automatically ends Valid values are 120 43200 seconds 2 720 minutes The default is 1800 seconds 30 minutes ui refresh uint16 User interface refresh rate which is 30 seconds authentication type For an SNMPv3 user this specifies whether to u...

Страница 492: ...mperature scale type string Fahrenheit PROPERTY PROPERTY name temperature scale numeric type string 0 PROPERTY PROPERTY name timeout type uint32 1800 PROPERTY PROPERTY name ui refresh type uint16 30 PROPERTY PROPERTY name authentication type type string PROPERTY PROPERTY name privacy type type string PROPERTY PROPERTY name password type string PROPERTY PROPERTY name privacy password type string PR...

Страница 493: ...Table 86 vdisk hist statistics properties Name Type Description total data transferred string Total amount of data read and written since the last sampling time total data transferred numeric uint64 Unformatted total data transferred value data read string Amount of data read since the last sampling time data read numeric uint64 Unformatted data read value data written string Amount of data writte...

Страница 494: ...494 XML API basetype properties PROPERTY name sample time numeric type string 1329397200 PROPERTY OBJECT ...

Страница 495: ...string Amount of data written since these statistics were last reset or since the controller was restarted data written numeric string Unformatted data written value avg rsp time string Average response time in microseconds for read and write operations calculated over the interval since these statistics were last requested or reset avg read rsp time string Average response time in microseconds fo...

Страница 496: ...PERTY name data read numeric type string 21078016 PROPERTY PROPERTY name data written units GB type string 80 0GB PROPERTY PROPERTY name data written numeric type string 80096836608 PROPERTY PROPERTY name avg rsp time type uint32 24884 PROPERTY PROPERTY name avg read rsp time type uint32 3003 PROPERTY PROPERTY name avg write rsp time type uint32 24917 PROPERTY PROPERTY name reset time type string ...

Страница 497: ...on type uint8 2 PROPERTY PROPERTY name disk channel_revision type uint8 2 PROPERTY Table 88 versions properties Name Type Description sc cpu type string Storage Controller processor type bundle version string Firmware bundle version build date string Firmware bundle build date sc fw string Storage Controller firmware version sc baselevel string Storage Controller firmware base level sc memory stri...

Страница 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...

Страница 499: ...pe virtual disk summary name virtual disk oid 1 format rows PROPERTY name name type string vd01 PROPERTY PROPERTY name serial number key true type string SN PROPERTY OBJECT Embedded basetypes vdisk hist statistics Table 89 virtual disk summary properties Name Type Description name string Vdisk name serial number string Vdisk serial number ...

Страница 500: ...ormal operation or the partner controller when the preferred owner is offline A Controller A B Controller B owner numeric string Numeric equivalents for owner values 0 B 1 A preferred owner string Controller that owns the vdisk and its volumes during normal operation A Controller A B Controller B preferred owner numeric string Numeric equivalents for preferred owner values 0 B 1 A raidtype string ...

Страница 501: ...online or if after 60 seconds from being quarantined the vdisk is QTCR or QTDN the vdisk is automatically dequarantined QTDN Quarantined with a down disk The RAID 6 vdisk has one inaccessible disk The vdisk is fault tolerant but degraded If the inaccessible disks come online or if after 60 seconds from being quarantined the vdisk is QTCR or QTDN the vdisk is automatically dequarantined QTOF Quaran...

Страница 502: ...unning string Same as current job current job string Job running on the vdisk if any blank No job is running DRSC The disk is being scrubbed EXPD The vdisk is being expanded INIT The vdisk is initializing RCON The vdisk is being reconstructed VRFY The vdisk is being verified VRSC The vdisk is being scrubbed current job numeric string Numeric equivalents for current job values 0 blank 2 INIT 3 RCON...

Страница 503: ...AS 5 SATA S 6 SAS S is job auto abortable string false The current job must be manually aborted before you can delete the vdisk true The current job will automatically abort if you delete the vdisk is job auto abortable numeric string 0 false 1 true serial number string Vdisk serial number blocks uint64 Unformatted size value in 512 byte blocks disk dsd enable vdisk string Disabled DSD is disabled...

Страница 504: ...string 585318784 PROPERTY PROPERTY name create date type string 2011 10 11 16 19 39 PROPERTY PROPERTY name create date numeric type string 1318349979 PROPERTY PROPERTY name cache read ahead units GB type string 2199 0GB PROPERTY PROPERTY name cache read ahead numeric units blocks512 type string 4294967295 PROPERTY PROPERTY name cache flush period type uint32 1 PROPERTY PROPERTY name read ahead ena...

Страница 505: ...eric units blocks512 type string 2006570880 PROPERTY PROPERTY name array drive type type string SAS PROPERTY PROPERTY name array drive type numeric type string 4 PROPERTY PROPERTY name is job auto abortable type string false PROPERTY PROPERTY name is job auto abortable numeric type string 0 PROPERTY PROPERTY name serial number key true type string SN PROPERTY PROPERTY name blocks blocksize 512 typ...

Страница 506: ...ERTY PROPERTY name status reason type string VC In Progress PROPERTY OBJECT Table 91 volume copy status properties Name Type Description vc_volume_name string Destination volume name serial number string Destination volume serial number virtual disk name string Destination vdisk name source volume string Source volume name progress string Percent complete of the volume copy 0 99 status string Unav...

Страница 507: ...fix type string vd02_v001_01 PROPERTY PROPERTY name include modified data type string preserved PROPERTY PROPERTY name last created type string PROPERTY OBJECT Table 92 volume copy tasks properties Name Type Description source volume name string Source volume name source volume serial string Source volume serial number destination vdisk name string Destination vdisk name destination vdisk serial s...

Страница 508: ...volume names name volume name oid 1 format rows PROPERTY name volume name type string vd01_v001 PROPERTY PROPERTY name serial number key true type string SN PROPERTY OBJECT Table 93 volume names properties Name Type Description volume name string Volume name serial number string Volume serial number ...

Страница 509: ...ring Host WWPN or iSCSI node name port string Controller ID and port number reserve type string The reservation type Undefined The volume has no persistent reservations Write Exclusive Write commands are only allowed for a single reservation holder Exclusive Access Certain access read write commands are only allowed for a single reservation holder Write Exclusive Registrants Only Write commands ar...

Страница 510: ...510 XML API basetype properties PROPERTY name reserve type numeric type string 0 PROPERTY OBJECT ...

Страница 511: ...g for a fault tolerant environment because it improves the performance of write operations and throughput This is the default write through Write through caching significantly impacts performance by waiting for data to be completely written to disk before signaling the host that the write is complete Use this setting only when operating in an environment with low or no fault tolerance write policy...

Страница 512: ...n of an in progress replication from a remote volume which when complete will change to type snapshot volume class numeric string Numeric equivalents for volume class values 0 standard 1 PTSNAP 3 Proxy volume qualifier string N A Non replication specific volume such as a standard volume master volume snapshot or snap pool RSR Replication specific volume such as a primary volume secondary volume re...

Страница 513: ...lume that identifies the volume to an OpenVMS host For HP UX a text value set in band by a host application that identifies the volume Blank by default wwn string World Wide Name of the volume used by host based Storage Replication Adapter SRA software to identify the volume progress string For a volume copy operation the percent complete 0 99 The default value is 0 progress numeric string Unforma...

Страница 514: ...OPERTY PROPERTY name volume type numeric type string 2 PROPERTY PROPERTY name volume class type string PTSNAP PROPERTY PROPERTY name volume class numeric type string 1 PROPERTY PROPERTY name volume qualifier type string RSR PROPERTY PROPERTY name volume qualifier numeric type string 2 PROPERTY PROPERTY name blocks blocksize 512 type uint64 195312384 PROPERTY PROPERTY name capabilities type string ...

Страница 515: ... read value data written string Amount of data written since these statistics were last reset or since the controller was restarted data written numeric string Unformatted data written value write cache hits uint64 For the controller that owns the volume the number of times the block written to is found in cache write cache misses uint64 For the controller that owns the volume the number of times ...

Страница 516: ...ROPERTY PROPERTY name small destages type uint64 1511 PROPERTY PROPERTY name full stripe write destages type uint64 12992 PROPERTY PROPERTY name read ahead operations type uint64 380397 PROPERTY PROPERTY name write cache space type uint16 0 PROPERTY PROPERTY name write cache percent type uint32 0 PROPERTY PROPERTY name reset time type string 2012 02 13 12 45 31 PROPERTY PROPERTY name reset time nu...

Страница 517: ...me volume view oid 1 format labeled PROPERTY name volume serial key true type string SN PROPERTY PROPERTY name volume name type string vd01_v001 PROPERTY OBJECT Embedded basetypes volume view mappings Table 97 volume view properties Name Type Description volume serial string Volume serial number volume name string Volume name ...

Страница 518: ...ring LUN that identifies the volume to a host Blank if not mapped or mapped as no access access string Type of host access to the volume read write The host has read and write access to the volume This is the default read only The host has read access to the volume no access The host is denied access to the volume not mapped The host is not mapped to the volume port wwn string For an FC or SAS hos...

Страница 519: ... Disabled Enabled Users All configured users are deleted and replaced with default user definitions and default settings User manage password manage User monitor password monitor User ftp password ftp Temperature scale Celsius Timeout 30 minutes CLI Telnet timeout 30 minutes Tasks and schedules preserved 1 Remote system definitions preserved 2 MC debug logs preserved 3 SC event logs preserved Time...

Страница 520: ...re configuration Enclosure polling rate Supercap failure CompactFlash failure Auto write back Disk background scrub Enabled Enabled High preserved 8 Disabled 5 seconds Enabled Enabled Enabled Disabled Native Command Queuing NCQ Enabled Managed Logs Disabled 1 Factory default no tasks or schedules 2 Factory default no remote system definitions 3 Factory default MC logs are cleared 4 Factory default...

Страница 521: ...gned if the dynamic spares option is enabled to replace a failed disk in a redundant vdisk See compatible disk EC Expander Controller The processor located in the SAS expander in each controller module and expansion module that controls the SAS expander and provides SES functionality See also EMP EMP Enclosure management processor An EC subsystem that provides SES data such as temperature power su...

Страница 522: ...conceptual term for replication snapshots that have the same image ID in primary and secondary systems These synchronized snapshots contain identical data and can be used for disaster recovery replication set Associated primary and secondary volumes that are enabled for replication and that typically reside in two physically or geographically separate storage systems See primary volume and seconda...

Страница 523: ...sts are counted against the snapshot license limit whereas transient and unmappable snapshots are not SRA Storage Replication Adapter A host based software component that allows VMware s Site Recovery Manager to manage the storage system firmware s disaster recovery management DRM features automating disaster recovery failover and failback tasks The SRA uses the CLI XML API to control the storage ...

Страница 524: ...524 Glossary ...

Страница 525: ...tion Protocol See CHAP CHAP create record 47 delete records 76 enable disable 158 set record 141 show records 201 show setting 247 characters versus bytes 22 23 CLI accessing 15 command syntax 22 enable disable XML brief mode 142 exit 96 output formats 15 scripting commands 16 scripting guidelines 19 set base for storage space sizes 142 set locale 142 set output format 142 set paging mode 143 set ...

Страница 526: ...tistics 117 reset performance statistics 118 set spin down delay 136 147 show data transfer rate 214 390 show disk scrub setting 193 show information 213 show maximum number of 293 show performance statistics 218 show SMART setting 212 show spin down delay 193 show spin down setting 193 show system SMART setting 191 show vdisk scrub interval setting 191 show vdisk scrub setting 191 start manual sc...

Страница 527: ...r iSCSI 156 set loop IDs for FC 155 set netmask address for iSCSI 156 show 240 257 show number of 293 show performance statistics 243 hosts create 48 set FC connection mode 155 set FC link speed 156 set nickname 48 154 set profile 48 154 show 245 show mappings 238 show whether use of profiles is enabled 293 HP Subscriber s choice web site 13 technical support 12 web sites 13 HTTP interface enable ...

Страница 528: ...sable 169 output format API 15 console 15 set CLI 142 show CLI 202 P paging mode set CLI 143 show CLI 202 parameter syntax 22 parameter values variable 22 parameters optional 22 partner firmware update enable disable 135 160 show setting 191 248 password set user 65 166 187 PHYs enable disable fault isolation 151 enable disable specific 152 ping a remote host 106 port syntax 22 ports show health f...

Страница 529: ...mation show enclosure 226 SES interface enable disable 169 shut down controller 327 shutdown show status 283 size representations in base 2 and base 10 23 SMART enable disable 135 147 show setting 191 212 SMI S reset configuration 121 SMI S interface enable disable secure 169 enable disable unsecure 169 snap pool set retention priorities 167 snap pools create 59 delete 83 expand 97 set automatic e...

Страница 530: ... 65 188 show CLI 203 temperatures show component 281 time and date set 144 show settings 205 timeout set CLI 143 set user 65 188 show CLI 202 trust vdisk for emergency data recovery 332 U ULP 293 units for storage space sizes set CLI 143 set user 66 188 show CLI 202 users authentication type for SNMPv3 64 186 create 64 delete 87 make session preferences permanent 187 privacy encryption password fo...

Страница 531: ...gs 102 clear unwritable cache data 38 convert master to standard 43 create 69 create master 49 create multiple with same settings 71 delete 90 delete all master 74 delete volume 79 expand 100 mask from hosts 102 optimize caching 139 release persistent reservations 109 reset performance statistics 125 roll back master 130 set name 190 set read ahead cache size 139 set the default mapping 69 set wri...

Страница 532: ...532 Index ...

Отзывы: